(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

3M 1626 - DRESSING TEGADERM LATEX FREE TRANSPARENT ORG FRAME 4X4-3/4"

3M # 1626 - DRESSING TEGADERM LATEX FREE TRANSPARENT ORG FRAME 4X4-3/4
Part Number 3M 1626
SKU Number CIA1000099
Sell Unit BOX
Ships Within 2-3 Days
List Price $50.23
Enter a valid quantity
Product Description

3M 1626 - DRESSING TEGADERM LATEX FREE TRANSPARENT ORG FRAME 4X4-3/4"

3M 1626 Tegaderm Transparent Film Dressing Frame Style

3M Tegaderm Transparent Film Dressing Frame Style is a sterile, vapour permeable transparent film dressing. 3M Tegaderm Transparent Film Dressings can be used to cover and protect catheter sites and wounds, to maintain a moist environment for wound healing, and to secure devices to the skin.

Features and Benefits of 3M 1626 Tegaderm Transparent Film Dressing Frame Style

  • Waterproof, sterile barrier: protects the I.V. site or wound from external contaminants such as bacteria, viruses, blood and body fluids in vitro testing shows that the transparent film provides a viral barrier from viruses 27 nm in diameter or larger while the dressing remains intact without leakage
  • Breathable film lets oxygen in and moisture vapour out
  • Picture-frame delivery makes placement accurate and easy, minimising potential to stick to gloves or to itself
  • Transparent dressing allows for continuous visibility to the I.V. insertion site
  • Dressing flexes with skin for greater patient comfort
  • May be worn up to 7 days
  • Radiologically transparent. Tegaderm products can be safely left on patients skin during radiotherapy treatments. Dressing does not act as bolus material, with or without 3M Cavilon No Sting Barrier Film (CNSBF)
  • Can be used to maintain a moist wound environment to facilitate autolytic debridement
  • Helps to prevent skin breakdown caused by friction

Application Hints for 3M 1626 Tegaderm Transparent Film Dressing Frame Style

  • Select a dressing size that will adequately cover the catheter and insertion site or wound. Ensure at least a one inch margin of dressing adheres to healthy, dry skin.
  • Prepare the catheter insertion site or wound according to your institutions approved protocol.
  • To ensure good adhesion, clip excess hair where the dressing will be placed. Do not shave the skin because of the potential for microabrasions.
  • Make sure skin is free of soaps, detergents, and lotions. Allow all preps and protectants to dry thoroughly before applying the dressing. Wet preps and soap residues can cause irritation if trapped under the dressing. Additionally, adhesive products do not adhere well to wet or oily surfaces.
  • Do not stretch the Tegaderm dressing during application. Applying an adhesive product with tension can produce mechanical trauma to the skin. Stretching can also cause adhesion failure.
  • The adhesive of Tegaderm dressing is pressure-sensitive. To ensure best adhesion, always apply firm pressure to the dressing from the center out to the edges.
  • To tailor a dressing for a special application, use sterile scissors to cut the dressing into desired shapes or sizes before removing the printed liner. For best results and ease of application, cut the pieces so that a portion of the frame remains on at least two sides.
Removal Hints
Support the skin when removing Tegaderm dressing. For removal from I.V. sites, also stabilize the catheter to prevent dislodgment. Use one of the following removal techniques based on your patients skin condition and your own personal preference:
  • Gently grasp one edge and slowly peel the dressing from the skin in the direction of hair growth. Try to peel the dressing back over itself, rather than pulling it up from the skin.
  • Grasp one edge of the dressing and gently pull it straight out to stretch and release adhesion.
  • Apply an adhesive remover suitable for use on skin to the adhesive edge while gently peeling from the skin.
To aid in lifting a dressing edge, secure a piece of surgical tape to one corner and rub firmly. Use the tape as a tab to help you slowly peel back the dressing.

3M 1626 Tegaderm Transparent Film Dressing Frame Style Specifications

Applications

Catheters Fixation

Border

Yes

Brands

Tegaderm

Cladimed Code

F51CA01

Clinical Sub-Area

Orthopedics

Condition

Dressing & Device Securement, I.V. Related, Pressure Ulcer, Skin Care, Wound Care

Department

Cardiovascular, Dialysis Center, Emergency, I.V. Therapy, Intensive Care Unit, Medical-Surgical, Oncology, Operating Room-Surgery, Pediatrics, Radiology, Urgent Care, Wound Care

Dressing Type

Film

Dressing and Device Securement Condition Type

Adhesive Trauma, Skin Injuries-Mechanical, Tube & Device Securement-Lightweight Tubes & Devices

Hypoallergenic

Yes

IV Related Condition Type

Arterial Catheter, CVC Dialysis, CVC Implanted Port, CVC PICC, CVC Short-Term, CVC Tunneled, Epidural Catheter, PICC, PIV

Latex

No

Product Type

Standard Dressing

Therapeutic Area and Conditions

Autolytic Debridement, Partial Thickness Wounds, Pressure Ulcers, Secondary Dressing, Surgical Incisions

Units per Pack

50

Waterproof

Yes

Dimensions and Classifications of 3M 1626 Tegaderm Transparent Film Dressing Frame Style

Overall Length (Metric)

12 cm

Overall Width (Metric)

10 cm

3M 1626 Tegaderm Transparent Film Dressing Frame Style Device Characteristics

What MRI safety information does the labeling contain?Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437):No
Device labeled as "Not made with natural rubber latex":Yes
For Single-Use:Yes
Prescription Use (Rx):No
Over the Counter (OTC):Yes
Kit:No
Combination Product:No
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P):No


Related Products