Baxter #2C6546 - Interlink Continu Flo Set 3-Sites 48/Ca

Baxter #2C6546 - Interlink Continu Flo Set 3-Sites 48/Ca
CIA1087609
CASE
Special Order
$283.04

Allow C.I.A. to white-glove your request for this item

Not buying today? Need a volume discount, Net 30 terms, or a government quote? Got a backorder, and need immediate stock? That’s exactly what we do best. Let us solve your problem.

Product Description

Baxter Part #2C6546 - Interlink Continu Flo Set 3-Sites 48/Ca

CONTINU-FLO Solution Set, Non-Vented, 3 INTERLINK Injection Sites, Backcheck Valve, Retractable Collar, 60 drops/mL, 106" (2.7 m)

Minidrip Continu-Flo Solution Sets

CONTINU-FLO Solution Set with Non-Vented Spike, 3 INTERLINK Injection Site, Backcheck Valve and Male Luer Lock Adapter with Retractable Collar. Approximately 60 drops/mL. Approximate Length 106" (2.7 m). Contains DEHP. Fluid path is sterile, nonpyrogenic.

Device Characteristics

What MRI safety information does the labeling contain?Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437):No
Device labeled as "Not made with natural rubber latex":Yes
For Single-Use:Yes
Prescription Use (Rx):Yes
Over the Counter (OTC):No
Kit:No
Combination Product:No
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P):No

Sterilization

Device Packaged as Sterile:Yes
Requires Sterilization Prior to Use:No

Pyrogen-free

Pyrogen is any substance that causes a fever. The most commonly thought of pyrogens are bacterial endotoxins and exotoxins, although the host body (human or animal) can also produce pyrogens. The most commonly assayed for pyrogen is lipopolysaccharide, or LPS. It is a component of the bacterial wall of Gram-negative bacteria and is released upon breakdown of the cell wall or bacterial cell lysis. Pyrogen-free products are manufactured in settings that prevent the deposition of bacteria and other agents on the products.

Contains DEHP

Diethyl hexyl Phthalate, A chemical commonly used in PVC tubing; used to yield clarity and soft pliable tubing.

Product Specifications

Manufacturer No.2C6546
ManufacturerBaxter
ApplicationAdministration Set
Length106 IN
Priming Volume16.6 ML
Drops per mL60
SpikeNon-Vented
Backcheck ValveYes
Type of Injection SiteINTERLINK
Number of Y-Sites3
Tubing ConfigurationStraight
Collar TypeRetractable
SterilitySterile Fluid Path
Rx OnlyYes

Packing Information

Length: 12.7 IN
Width: 10.9 IN
Height:8.5 IN
Volume: 0.68 FC
Weight: 5.4 LB
Pack Factor: 48