(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 21-6300-51 - CADD-LEGACY PCA Infusion Pump, Each

Smiths Medical # 21-6300-51 - CADD-LEGACY PCA Infusion Pump, Each
Part Number Smiths Medical 21-6300-51
SKU Number CIA1071822
Sell Unit EACH
Ships Within Special Order
List Price $3,272.39
Enter a valid quantity
Product Description

Smiths Medical 21-6300-51 - CADD-LEGACY PCA Infusion Pump, Each

Smiths Medical 21-6300-51 CADD-LEGACY PCA Infusion Pump

CADD-Legacy PCA Ambulatory Infusion Pump, Model 6300 for continuous clinician-activated bolus and patient-activated bolus infusions. The CADD-Legacy PCA pump is for pain management therapies because performance runs in the family.

  • Includes pump, single-use 50-/100-mL pump pouch, 2 AA batteries, non-sterile demo cassette, operators manual, patient information guide, and carrying case.

Smiths Medical 21-6300-51 CADD-LEGACY PCA Infusion Pump Benefits

  • Easy to Read Display
    • Easy to read and understand display screen provides information for programming adjustments and troubleshooting. New display messages, such as
  • Cassette Detection
    • Cassette detection sensor is designed to detect cassette attachment
  • Occlusion Detection
    • Upstream and downstream occlusion sensors are designed to alert the patient and clinician if interruption of fluid delivery occurs
  • Air-in-Line Detection
    • Air-in-line detector with Off, High- and Low-sensitivity settings is designed to alert the patient and clinician if air is present in the administration set tubing
  • ON/OFF Key
    • ON/OFF key allows pump to be placed in low-power state and is designed to save battery life
  • Event Memory
    • The last 1,000 events in the pump's history can be downloaded either directly or remotely (using a modem) to a PC using the CADD-DIPLOMATPC Communications System
  • Reliability
    • CADD pump reliability and durability can mean less down time and fewer interruptions to therapy
  • Programming Flexibility
    • Convenient programming in milliliters, milligrams or micrograms and expanded concentration ranges

Device Characteristics of Smiths Medical 21-6300-51 CADD-LEGACY PCA Infusion Pump

What MRI safety information does the labeling contain?Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry
natural rubber (21 CFR 801.437):
No
Device labeled as "Not made with natural rubber latex":No
For Single-Use:No
Prescription Use (Rx):Yes
Over the Counter (OTC):No
Kit:No
Combination Product:No
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P):No
Related Products