(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 305215 - Needle 18Gx1-1/2 Admx PrecisionGlide Nokor Strl Shlf Pk, 100/BX, 10 BX/CA

BD  # 305215 - Needle 18Gx1-1/2 Admx PrecisionGlide Nokor Strl Shlf Pk, 100/BX, 10 BX/CA
Part Number BD 305215
SKU Number CIA2288292
Sell Unit CASE
Ships Within Special Order
List Price $269.50
Enter a valid quantity
Product Description

BD 305215 - Needle 18Gx1-1/2 Admx PrecisionGlide Nokor Strl Shlf Pk, 100/BX, 10 BX/CA

TheBD 305215 PrecisionGlide Nokor Needleis asterile, single-use 18-gauge x 1.5-inch hypodermic needle, specifically designed foraspiration of fluids, biopsy material, and withdrawal of viscous substances. Featuring aNokor beveled tipand BD's trustedPrecisionGlide stainless steel technology, this needle ensurescontrolled access, reduced coring, and clean cutsfor high-precision medical applications.

Packaged in ashelf pack for efficient storage and access, this needle is ideal for clinical professionals who require dependable, sterile instruments for procedures involvingtough tissue penetration or large fluid extractions.

Key Product Features

Hub ColorPink
Hub MaterialPolypropylene
Hub TypeLuer
Needle Gauge18 G
Needle Gauge (m)1.20 mm
Needle Length (in.)1-1/2 in.
Needle Length (m)38.10 mm
Needle Tip TypeBD Nokor
Needle TypeFill
Needle Wall TypeThin wall
Total Shelf Life1825
SterileSterilized product
Type Of BevelBD Nokor
Sterilization MethodRadiation
BPA FreeNot made with BPA
DEHP FreeNot made with DEHP
Latex StatementNot made with natural rubber latex
PVC FreeNot made with PVC
DisposableDisposable product
Single UseProduct is for single use only

Key Benefits:

  • 18 Gauge Diameter and 1.5" Length: Ideal for penetrating dense tissues and withdrawing thick fluids.

  • Nokor Beveled Tip: Designed to minimize tissue trauma and reduce sample contamination.

  • BD PrecisionGlide Stainless Steel: Provides durability, sharpness, and smooth insertion with minimal resistance.

  • Sterile, Single-Use Design: Ensures patient safety and compliance with infection control standards.

  • Shelf Pack Configuration: Enhances efficiency for high-volume clinical environments.

  • Latex-Free and DEHP-Free: Safe for use in sensitive patients or allergy-prone environments.

Compatibility and Applications:
Compatible with:

  • Luer-Lok and slip-tip syringes

  • Biopsy systems or manual aspiration setups

Common medical applications include:

  • Aspirating thick fluids (e.g., abscesses, cystic fluids, fat)

  • Sampling soft tissue for diagnostic testing

  • Withdrawing medication from multi-dose vials with minimal coring

  • Fine-needle aspiration (FNA) in cytology and pathology

  • Procedures in interventional radiology, surgery, or primary care settings

Usage Guidelines:

  • Inspect packaging for damage prior to use.

  • Attach securely to a compatible syringe using a Luer-Lok or slip-tip fitting.

  • Use aseptic technique to perform aspiration or withdrawal.

  • Do not reuse the needle. Dispose of immediately in a designated sharps container.

  • Use with caution when aspirating near nerves or arteriesfollow clinical protocols.

Certifications, Safety Standards, and Regulatory Approvals:

  • FDA Approvedfor aspiration and hypodermic procedures

  • CE Markedfor compliance with European medical device standards

  • ISO 7864 and ISO 9626 Certifiedfor sterile single-use needles and cannulae

  • Manufactured in an ISO 13485 Certified Facility

  • CDC- and OSHA-Compliantfor clinical safety and sharps disposal

These approvals reflect the BD 305215s adherence to global safety, quality, and performance standards in demanding healthcare environments.

Comparison with Competitor Products:
Compared to other 18G aspiration needles, theBD 305215stands out due to:

  • Nokor specialty tip, engineered to reduce core displacement and preserve sample integrity

  • PrecisionGlide sharpness, reducing insertion force and patient discomfort

  • Consistent manufacturing quality from BD, a trusted name in sterile needle technology

  • Shelf pack format, preferred in high-usage clinical settings for quick access and reduced handling

Generic alternatives may not offer the same needle sharpness, structural integrity, or tip precision, potentially increasing sample damage or patient discomfort.

Typical User Profile and Application Scenarios:
Used by:

  • Physicians, nurses, and interventional specialists

  • Radiologists and cytologists

  • Clinical lab and pathology professionals

  • Primary care physicians and minor procedure clinics

Common scenarios include:

  • Fine-needle aspiration (FNA) for biopsy sample collection

  • Drainage of cysts or localized abscesses

  • Withdrawal of viscous medications from vials

  • Use in diagnostic imaging support procedures

  • Collection of fat or fluid for research or testing purposes

Best Practices for Use and Maintenance:

  • Store in a clean, dry, room-temperature environment

  • Maintain a sterile field when opening and attaching the needle

  • Use only once and dispose of properly to prevent needle-stick injuries

  • Select the correct gauge and length for the procedure based on fluid viscosity and tissue depth

  • Ensure proper training before use in aspiration or biopsy procedures

Regulatory and Safety Information:
The BD 305215 meets or exceeds regulatory requirements for sterile hypodermic needles, with full compliance withFDA,CE,ISO,CDC, andOSHAstandards. It is aClass II medical device, engineered to ensure bothperformance and patient safetyduring fluid aspiration procedures.

Device Characteristics

What MRI safety information does the labeling contain?Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437)No
Device labeled as "Not made with natural rubber latex"No
For Single-UseYes
Prescription Use (Rx)Yes
Over the Counter (OTC)No
KitNo
Combination ProductNo
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P)No

Product Packaging Information

Packaging LevelShelfpackEachCase
Quantity10011000
Length116.0 mm451.0 mm
Width88.0 mm206.0 mm
Height98.0 mm129.0 mm
Weight141.9 g1.419 g1.419 kg

How to Order:
To order theBD 305215 18G x 1.5" PrecisionGlide Nokor Needle, simply:

  • Select the required quantity on the CIA Medical product page

  • Click Add to Cart and follow the secure checkout process

Forbulk inquiries, product guidance, or additional information, contactCIA Medical customer service at (312) 275-5850or use the contact form on this page. Our knowledgeable team is ready to support your clinical supply needs.

Related Products