B Braun 352895 - IV Administration Set, Standard Bore Extension Set with Female Luer Lock Connector & Two Needle-Free Access Ports - Reliable and Flexible Solution for Safe Fluid Delivery, 50/CS (Rx)

B Braun # 352895 - IV Administration Set, Standard Bore Extension Set with Female Luer Lock Connector & Two Needle-Free Access Ports - Reliable and Flexible Solution for Safe Fluid Delivery, 50/CS (Rx)
Part Number B Braun 352895
SKU Number CIA8039627
Sell Unit CASE
Ships Within Special Order
List Price $223.41
Enter a valid quantity
Product Description

B Braun 352895 - IV Administration Set, Standard Bore Extension Set with Female Luer Lock Connector & Two Needle-Free Access Ports - Reliable and Flexible Solution for Safe Fluid Delivery, 50/CS (Rx)

The B Braun 352895 IV Administration Set is a high-quality, standard bore extension set designed to facilitate precise and safe intravenous (IV) fluid delivery. It features a female Luer lock connector and two needle-free access ports, which help minimize the risk of needlestick injuries by allowing safe access to the IV line without using needles. With a 35-inch (88.9 cm) length, the set is versatile, providing flexibility and ease of use in various medical environments, including hospitals, outpatient clinics, and surgical units.

This extension set is equipped with a sliding SPIN-LOCK connector, providing secure and leak-proof connections to infusion pumps and other medical devices. Made from DEHP-free and latex-free materials, the set is designed to be safe for patients with sensitivities to these substances. The set has a priming volume of 5.5 mL, ensuring that it can effectively handle fluid administration while maintaining a sterile environment. Pre-sterilized and ready for use, this IV administration set is a reliable tool for healthcare professionals to ensure efficient and controlled fluid and medication delivery.

Key Benefits

The B Braun 352895 IV Administration Set offers several key benefits for healthcare professionals and patients:

  • Precise Fluid Delivery: With a standard bore design and a 5.5mL priming volume, this extension set ensures accurate fluid infusion, making it suitable for a wide range of medical treatments, including fluid replacement and medication administration.
  • Needle-Free Access Ports: The two needle-free access ports allow for the safe and easy addition of fluids or medications without the need for needles, reducing the risk of contamination and needlestick injuries.
  • Female Luer Lock Connector: The female Luer lock connector provides a secure, leak-proof connection to IV lines, reducing the risk of fluid leakage or disconnections during the infusion process.
  • Sliding SPIN-LOCK Connector: The SPIN-LOCK connector ensures a firm and secure connection to infusion pumps and other medical devices, minimizing the risk of accidental disconnections during fluid administration.
  • DEHP-Free and Latex-Free: The set is made from materials that are both DEHP-free and latex-free, reducing the risk of allergic reactions and making it a safer option for patients with sensitivities to these substances.
  • Versatile Length and Flexibility: With a 35-inch (88.9 cm) length, the extension set provides flexibility in positioning and usage, making it ideal for use in a variety of healthcare settings.
  • Sterile and Ready to Use: The set is pre-sterilized, ensuring a sterile environment for patient care and reducing preparation time.

Compatibility and Applications

The B Braun 352895 IV Administration Set is compatible with a wide range of intravenous fluids, medications, and infusion devices. It is ideal for use in:

  • IV Fluid Administration: Used for the delivery of IV fluids such as saline, glucose, and electrolyte solutions, ensuring hydration and fluid balance in patients.
  • Medication Infusion: Ideal for administering medications such as antibiotics, chemotherapy, or pain management drugs, ensuring accurate and controlled infusion.
  • Surgical and Postoperative Care: Commonly used during and after surgical procedures to maintain fluid balance and administer postoperative medications.
  • Critical Care: Often used in intensive care units (ICUs) and emergency departments (EDs) where continuous infusion of fluids and medications is required to stabilize patients.
  • Outpatient Clinics: Suitable for outpatient infusion centers where patients may need ongoing or long-term intravenous treatments, such as chemotherapy or IV antibiotics.

Usage Guidelines

To ensure the proper and safe use of the B Braun 352895 IV Administration Set, healthcare professionals should follow these guidelines:

  • Priming the Set: Before use, prime the extension set with the appropriate fluid to remove any air bubbles and ensure smooth fluid flow. This step also prevents air embolism during the infusion process.
  • Check Secure Connections: Ensure that the female Luer lock connector and SPIN-LOCK connector are tightly secured before starting the infusion. A loose connection can result in leaks or disconnections during the infusion.
  • Needle-Free Access Ports: The set features two needle-free access ports, which should be used to add medications or fluids without the need for a needle. These ports reduce the risk of contamination and improve workflow efficiency.
  • Single Use Only: The extension set is designed for single use only. After the infusion is complete, dispose of the set properly in accordance with medical waste disposal protocols to ensure patient safety and prevent contamination.
  • Monitor the Infusion: During the infusion, continuously monitor the patient for any adverse reactions such as swelling, infection, or infiltration at the IV site.
  • Sterile Handling: Always handle the extension set using sterile techniques to minimize the risk of infection or contamination.

Certifications, Safety Standards, and Regulatory Approvals

The B Braun 352895 IV Administration Set complies with all relevant FDA and CE certification standards, ensuring that it meets rigorous safety, quality, and performance requirements for medical devices. These certifications provide healthcare professionals with confidence in the safety and efficacy of the set for patient care.

Comparison with Competitor Products

Compared to other IV extension sets on the market, the B Braun 352895 stands out for its combination of features, including the two needle-free access ports, DEHP- and latex-free materials, and the sliding SPIN-LOCK connector. These features ensure safer, more efficient fluid administration and reduce the risk of complications.

Many competitor products may only offer a single access port or less secure connections, which could compromise the fluid delivery process. Additionally, the DEHP- and latex-free materials make the B Braun 352895 extension set a safer choice for patients with sensitivities to these substances.

Typical User Profile and Application Scenarios

The B Braun 352895 IV Administration Set is commonly used by healthcare professionals such as nurses, physicians, infusion specialists, and medical technicians. It is ideal for use in the following scenarios:

  • Critical Care Units (ICUs): Used in ICUs to ensure safe and continuous fluid and medication administration to critically ill patients.
  • Surgical and Recovery Rooms: Ideal for managing IV fluid and medication infusions during and after surgery, maintaining patient hydration and medication levels.
  • Emergency Departments (EDs): Commonly used in emergency settings to rapidly deliver fluids and medications to stabilize patients in urgent situations.
  • Outpatient Clinics: Suitable for use in outpatient infusion centers where patients require long-term IV treatments such as chemotherapy or pain management.
  • Trauma Centers: Used in trauma care for quick and efficient fluid and medication delivery to stabilize patients with critical injuries.

Best Practices for Use and Maintenance

To ensure optimal performance and patient safety, healthcare professionals should follow these best practices:

  • Monitor Patient Response: Regularly monitor the patient for any signs of adverse reactions, such as swelling, infection, or discomfort at the infusion site.
  • Secure All Connections: Double-check that all connections, including the SPIN-LOCK and Luer lock connectors, are securely attached before starting the infusion.
  • Dispose of Properly After Use: After completing the infusion, safely dispose of the extension set according to medical waste disposal protocols.
  • Sterile Handling: Handle the set using sterile techniques to ensure that the infusion is delivered in a sterile and safe environment.

Regulatory and Safety Information

The B Braun 352895 IV Administration Set is FDA-approved and CE-certified, ensuring that it meets the highest international standards for safety and performance. This certification provides healthcare professionals with the assurance that the product is safe and reliable for use in clinical environments.

How to Order

Ordering the B Braun 352895 IV Administration Set is simple. Add the product to your cart and proceed through the secure checkout process. For bulk orders or additional inquiries, please contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page. Our team is happy to assist you with any questions or special requests regarding this product.