Baxter 2N8395 - VIAL, CLEAR, LINK, ADPT-ALLOCATION REQ, EACH

Baxter # 2N8395 - VIAL, CLEAR, LINK, ADPT-ALLOCATION REQ, EACH
Part Number Baxter 2N8395
SKU Number CIA2036381
Sell Unit EACH
Ships Within 24 Hours
List Price Call for Pricing
Product Description

Baxter 2N8395 - VIAL, CLEAR, LINK, ADPT-ALLOCATION REQ, EACH

Universal Vial Adapter, CLEARLINK Luer Activated

Universal Vial Adapter, CLEARLINK Luer Activated , Non-DEHP, Non-PVC. Sterile package, Nonpyrogenic.

Directions for Use: Use Aseptic Technique

Prepare vial closure and stopper using approved technique. Remove tip protector. Locate spike at center of vial stopper (Figure1) and firmly push and twist until spike is fully inserted and flange rests on top of vial. Swab Luer activated surface with preferred antiseptic prior to first use and before every subsequent connection. To connect syringe, grasp flange of vital adapter. Firmly push male Luer syringe directly against Luer activated surface and rotate until connection is secure (Figure 2). Inject a volume of air into the vial equal to the amount of drug to be withdrawn. Reconstitute drug if required and withdraw desired amount of solution using approved technique. To disconnect syringe from vial adapter, grasp flange of vial adapter and rotate syringe counterclockwise (Figure 2).

Repeat swabbing steps for subsequent dose withdrawals.

Cautions

Do not access Luer activated valve with needles or cannula. Attempting such access will render the product damaged, discard adapter and vial immediately. Grasp flange and drug vial wile injecting air, withdrawing drug, connecting and removing syringe to ensure spike remains fully seated in vial (Figure2). If spike does not remain fully seated, contamination may occur. Always inject air before withdrawing drug to ease withdrawal and ensure Luer activated surface returns to a swabable position. Otherwise this surface may recess, and ineffective swabbing may result. Use of Luer lock connection is recommended. If Luer slip syringe is used, insert into septum using a firm push and twist motion.

For Dosage and Administration

  • See drug package insert. Discard vial/adapter assembly on or before expiration of drug or within 72 hours, whichever comes first.

Notes

  • This product does not contain natural rubber latex. This product does not contain DEHP. Flush Luer activated valve after injection to prevent inadvertent of incompatible medications/fluids.