-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
BD 228171 - Salmonella O Antiserum Factor 8 for Serological Identification of Salmonella O Antigen 8
The BD 228171 Salmonella O Antiserum Factor 8 is a high-specificity diagnostic reagent developed for the serological identification of Salmonella strains expressing O antigen factor 8. Manufactured by BD, a globally trusted leader in microbiology diagnostics, this antiserum is designed to produce clear and reliable agglutination reactions when used in standard laboratory testing protocols.
This reagent plays a critical role in the detailed serotyping of Salmonella isolates following primary culture. By targeting a specific somatic antigen factor, it enables laboratories to refine identification beyond broad serogroup classification. The formulation ensures consistent sensitivity and specificity, supporting accurate differentiation of Salmonella strains in clinical, food safety, and public health laboratories.
Key Benefits
The BD 228171 antiserum delivers precise identification of Salmonella O antigen factor 8, supporting accurate serotyping and improved diagnostic confidence. Its high specificity minimizes cross-reactivity, ensuring reliable results even in complex bacterial samples.
The ready-to-use liquid formulation simplifies laboratory workflows and reduces preparation time. Strong and distinct agglutination reactions enhance visual interpretation, allowing technicians to quickly confirm results.
By enabling detailed pathogen identification, this product contributes to effective infection control, epidemiological tracking, and targeted public health responses.
Compatibility and Applications
The BD 228171 Salmonella O Antiserum is fully compatible with standard slide agglutination techniques used in microbiology laboratories. It works effectively with isolates cultured on commonly used selective media such as MacConkey agar, Hektoen enteric agar, or similar enteric culture media.
Typical applications include clinical microbiology laboratories, hospital diagnostic centers, food safety testing facilities, and public health laboratories. It is widely used for confirmatory serotyping of Salmonella isolates and for epidemiological investigations.
Usage Guidelines
Ensure the reagent is stored under recommended conditions and brought to room temperature before use. Gently mix the antiserum to achieve uniform consistency without introducing bubbles.
Place a small portion of the bacterial colony onto a clean glass slide, add a drop of the antiserum, and mix gently. Observe for visible agglutination within the recommended time frame. A positive reaction indicates the presence of O antigen factor 8.
Always include appropriate positive and negative controls to validate test performance. Refer to the manufacturers instructions for detailed procedures and interpretation guidelines.
Certifications and Safety Standards
The BD 228171 antiserum is manufactured under strict quality control systems that comply with internationally recognized standards such as ISO certification and Good Manufacturing Practices. These standards ensure consistent product quality, safety, and performance.
The product is intended for in vitro diagnostic use and aligns with regulatory requirements such as FDA clearance and CE marking where applicable. These certifications confirm adherence to stringent safety and performance criteria.
Comparison with Competitor Products
Compared to other Salmonella antisera, the BD 228171 stands out for its high specificity and consistent agglutination clarity. Generic or lower-quality alternatives may exhibit variability in reactivity, leading to less reliable results.
BDs extensive expertise in microbiology diagnostics ensures rigorous validation and dependable performance. The products ability to target a specific antigen factor provides an advantage in detailed serotyping compared to broader antisera.
Its reliability and compatibility with standard protocols make it a preferred choice for laboratories requiring precise identification.
Typical User Profile and Application Scenarios
The BD 228171 Salmonella O Antiserum is used by microbiologists, laboratory technicians, and clinical diagnosticians involved in bacterial identification and serotyping. It is also utilized by public health professionals and researchers studying infectious disease patterns.
Common scenarios include confirmatory testing of Salmonella isolates, outbreak investigations, and surveillance programs. Laboratories rely on this product to achieve accurate and detailed pathogen classification.
Best Practices for Use and Maintenance
Store the antiserum at recommended temperatures and avoid exposure to extreme conditions. Do not freeze unless specified by the manufacturer.
Check the expiration date before use and discard any reagent that shows signs of contamination or degradation. Use clean slides and sterile tools to prevent cross-contamination.
Minimize repeated exposure to air by closing the container promptly after use. Proper handling ensures consistent performance and reliable results.
Regulatory and Safety Information
The BD 228171 Salmonella O Antiserum Factor 8 is intended for professional laboratory use only. Users should follow all biosafety protocols when handling bacterial cultures and diagnostic reagents.
The product complies with regulatory standards for in vitro diagnostic reagents, ensuring safe and reliable use in clinical and research environments. Dispose of used materials according to biohazard waste regulations.
How to Order
Ordering the BD 228171 Salmonella O Antiserum Factor 8 is simple through CIA Medical. Locate the product on the website, add it to your cart, and proceed through the secure checkout process.
For bulk orders, pricing inquiries, or additional assistance, contact CIA Medical customer service at (312) 275-5850. Their team is available to support your laboratory supply needs with expert guidance.