(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 23275-560 - Neuro Patties, 1" x 3", Strung Rayon, Sterile, X-Ray Detectable, 10/PK, 2 PK/CS (Temp Sensitive; Non-Returnable)

BD  # 23275-560 - Neuro Patties, 1
Part Number BD 23275-560
SKU Number CIA8042430
Sell Unit CASE
Ships Within Special Order
List Price $462.91
Enter a valid quantity
Product Description

BD 23275-560 - Neuro Patties, 1" x 3", Strung Rayon, Sterile, X-Ray Detectable, 10/PK, 2 PK/CS (Temp Sensitive; Non-Returnable)

The BD 23275-560 Neuro Patties are sterile surgical patties designed for controlled fluid management, tissue protection, and precise handling during neurosurgical and other delicate surgical procedures. Each patty measures 1 inch by 3 inches, or 2.5 cm by 7.6 cm, and features strung rayon construction for controlled placement and enhanced visibility within the operative field.

The rayon material becomes highly pliable when wet, allowing the neuro patty to conform closely to anatomical contours. This flexibility supports careful positioning around delicate tissues and structures where conventional surgical sponges may be too bulky or less adaptable.

The elongated 1" x 3" configuration provides broader coverage across a longer procedural area while maintaining a relatively thin surgical profile. The BD 23275-560 is X-ray detectable, supplied sterile, and not made with natural rubber latex. It is packaged 10 patties per pack and 20 packs per case, providing a total of 200 neuro patties for hospitals, neurosurgical departments, operating rooms, and specialty surgical facilities.

Key Benefits

  • 1" x 3" elongated profile supports controlled coverage of larger or extended neurosurgical areas.
  • Rayon construction becomes highly pliable when wet, helping the patty conform to anatomical contours.
  • Attached thread improves visibility and supports identification within the operative field.
  • X-ray detectable construction supports retained surgical item prevention procedures.
  • Sterile presentation supports established aseptic surgical technique and infection-control protocols.
  • Helps manage localized blood and other procedural fluids during appropriate surgical procedures.
  • Can support protection, separation, and cushioning of delicate anatomical structures.
  • Not made with natural rubber latex for facilities managing latex-related product requirements.
  • Ten patties per pack support organized procedural preparation and surgical item accountability.
  • Twenty packs per case provide 200 patties for efficient institutional inventory management.

Compatibility and Applications

The BD 23275-560 Neuro Patties are designed for integration into established neurosurgical and precision surgical workflows. They may be positioned and handled with appropriate surgical forceps or other compatible instruments when instrument-assisted placement, adjustment, or retrieval is required.

Typical applications may include cranial surgery, spinal procedures, neurosurgery, microsurgery, localized fluid absorption, protection of delicate tissues, and controlled separation or cushioning of anatomical structures during appropriate surgical techniques.

The 1" x 3" configuration may be particularly useful when a longer surgical patty is required to cover or protect an extended anatomical area while maintaining a relatively slim and conformable profile.

The product is suitable for hospital operating rooms, neurosurgical departments, specialty surgical centers, and other controlled healthcare environments. Suitability for a particular anatomical application or surgical technique should be determined by the qualified healthcare professional performing the procedure.

Usage Guidelines

Before use, confirm the BD 23275-560 catalog number, 1" x 3" dimensions, strung rayon construction, sterile package integrity, and suitability for the intended procedure. Do not use the product if the sterile packaging is opened, damaged, wet, punctured, or otherwise compromised.

  • Use appropriate aseptic technique when opening the package and introducing the patties into the sterile field.
  • Maintain the attached thread in a visible and accessible position whenever clinically appropriate.
  • Use suitable surgical instruments when instrument-assisted placement or retrieval is required.
  • Moisten the patty only when appropriate for the surgical technique and consistent with clinical requirements.
  • Apply controlled handling around delicate neurological tissues and anatomical structures.
  • Follow established surgical item counting procedures before, during, and after the procedure.
  • Account for every neuro patty introduced into the operative field before completing the procedure.
  • Dispose of used patties according to institutional infection-control and regulated medical waste procedures.

Healthcare professionals should review current manufacturer labeling and applicable institutional protocols for complete product-specific handling, warnings, storage, and disposal information.

Certifications and Safety Standards

The BD 23275-560 Neuro Patties are intended for professional healthcare use and should be handled in accordance with applicable medical device regulations, infection-prevention procedures, surgical safety protocols, and current manufacturer documentation.

The sterile presentation supports use within controlled surgical environments when package integrity and appropriate aseptic technique are maintained. The X-ray detectable design provides an additional identification feature for retained surgical item prevention procedures.

The attached thread enhances visibility and assists with identification within the operative field. These safety features should complement established manual counting, visual inspection, count reconciliation, and institutional retained surgical item prevention procedures rather than replace them.

Healthcare facilities and procurement teams should verify current manufacturer documentation for applicable regulatory status, UDI information, sterilization details, expiration dating, material specifications, and other product-specific requirements.

Comparison with Competitors

Compared with conventional gauze sponges, the BD 23275-560 Neuro Patties provide a thinner and more conformable profile for delicate neurosurgical applications. Standard gauze products are generally better suited for broad-area absorption, while neuro patties are designed for precise placement around sensitive anatomical structures.

Compared with cotton neuro patties, the rayon construction of the BD 23275-560 is designed to become highly pliable when wet, allowing it to conform closely to anatomical contours. Selection between rayon and cotton patties should be based on the surgical technique, desired handling characteristics, absorbency requirements, and clinician preference.

Compared with shorter neuro patties, the 3-inch length provides broader longitudinal coverage for extended procedural areas. The 1-inch width also provides a larger contact surface than narrower configurations while maintaining a manageable profile for precision surgical use.

Similar competitor products may vary in material, dimensions, string configuration, flexibility, X-ray detectability, sterility, and packaging quantity. The BD 23275-560 combines a 1" x 3" rayon profile, attached visibility thread, sterile presentation, and X-ray detectability for professional neurosurgical use.

Typical User Profile and Application Scenarios

The BD 23275-560 Neuro Patties are intended for use by trained healthcare professionals involved in neurosurgical and precision surgical procedures. Typical users may include neurosurgeons, spine surgeons, specialty surgeons, operating room nurses, surgical technologists, and other qualified clinical personnel responsible for surgical field management.

Typical application scenarios include procedures requiring localized fluid absorption, protection of delicate neurological tissue, controlled separation of anatomical structures, cushioning of sensitive areas, or placement of a conformable surgical patty within a confined operative field.

The 1" x 3" configuration is particularly relevant when a longer and wider patty is required for extended localized coverage. The product is well suited for hospitals, neurosurgical operating rooms, specialty surgical centers, and healthcare facilities that maintain formal surgical item accountability procedures.

Best Practices for Use and Maintenance

The BD 23275-560 is a sterile surgical consumable and should be stored, handled, used, and disposed of according to current manufacturer labeling and healthcare facility procedures. It is not intended to be maintained as reusable surgical equipment.

  • Store unopened products according to manufacturer-recommended environmental conditions.
  • Protect sterile packaging from moisture, contamination, excessive heat, crushing, and physical damage.
  • Rotate inventory according to expiration dates when applicable.
  • Verify the correct catalog number and 1" x 3" dimensions before opening the package.
  • Inspect the sterile barrier and product condition before use.
  • Keep the attached thread visible and accessible according to the surgical technique.
  • Maintain accurate counts of all neuro patties introduced into the operative field.
  • Do not rely solely on the visibility thread or X-ray detectability as a substitute for established counting procedures.
  • Do not reuse or reprocess the product when designated for single use.
  • Dispose of used products according to applicable infection-control and medical waste requirements.

Regulatory and Safety Information

The BD 23275-560 Neuro Patties should be used only by appropriately trained healthcare professionals and only for applications consistent with current manufacturer labeling, professional clinical judgment, and institutional policy.

Before use, verify the product identity, 1" x 3" dimensions, rayon construction, attached thread, sterile package integrity, expiration information when applicable, and suitability for the intended procedure.

Every neuro patty introduced into an operative field should be incorporated into the healthcare facility's established surgical item counting and retained item prevention procedures. The attached thread supports visibility, while X-ray detectability provides an additional identification feature when clinically necessary. Neither feature replaces manual counting, visual inspection, count reconciliation, or other established surgical safety protocols.

The product is supplied sterile and is not made with natural rubber latex. Specific FDA status, UDI information, sterilization method, expiration requirements, and other regulatory characteristics should be confirmed from current manufacturer documentation when required for purchasing, facility approval, or clinical use.

How to Order

Select the BD 23275-560 - Neuro Patties, 1" x 3", Sterile and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products