(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 260661 - Sensi-Disc Dispenser, 6-Place Manual Cartridge Dispenser for Antibiotic Susceptibility Testing, EA

BD  # 260661 - Sensi-Disc Dispenser, 6-Place Manual Cartridge Dispenser for Antibiotic Susceptibility Testing, EA
Part Number BD 260661
SKU Number CIA1087907
Sell Unit EACH
Ships Within Special Order
List Price $1,676.07
Enter a valid quantity
Product Description

BD 260661 - Sensi-Disc Dispenser, 6-Place Manual Cartridge Dispenser for Antibiotic Susceptibility Testing, EA

The BD 260661 - BD Sensi-Disc 6-Place Dispenser is a precision-engineered manual disc dispenser designed for use in antimicrobial susceptibility testing (AST) using the Kirby-Bauer disc diffusion method. Manufactured by Becton Dickinson (BD), this dispenser accommodates up to six antibiotic cartridges, allowing simultaneous placement of six Sensi-Discs on an inoculated agar plate with one smooth, even motion. The design ensures consistent disc spacing and accurate placement, reducing handling errors and maintaining the integrity of antibiotic susceptibility tests.

Constructed from durable, chemical-resistant materials, the BD 6-Place Dispenser is easy to operate, clean, and maintain. It supports efficient laboratory workflows by improving accuracy, speed, and reproducibility in antimicrobial testing procedures.

Key Benefits

The BD Sensi-Disc 6-Place Dispenser provides multiple advantages for clinical and research microbiology laboratories:

  • High precision and consistency: Ensures uniform placement and spacing of antibiotic discs for reproducible inhibition zones.
  • Simultaneous dispensing: Places up to six discs at once, improving efficiency and reducing operator time.
  • Reduced contamination risk: Minimizes direct handling of antibiotic discs, maintaining sterility and accuracy.
  • Durable and easy to maintain: Made from long-lasting, chemical-resistant materials suitable for repeated use.
  • Compatible with BD Sensi-Disc cartridges: Designed for seamless integration with BDs antibiotic susceptibility testing line.

Compatibility and Applications

The BD 260661 Dispenser is fully compatible with BD Sensi-Disc antibiotic cartridges and works with standard 90100 mm agar plates used in the Kirby-Bauer disc diffusion test. It is ideal for use in:

  • Clinical microbiology laboratories conducting routine antimicrobial susceptibility testing.
  • Hospital laboratories performing antibiotic resistance surveillance.
  • Pharmaceutical and academic research labs evaluating antibiotic efficacy.
  • Public health laboratories engaged in antimicrobial resistance monitoring.

The dispenser supports use across a wide range of bacterial isolates and antibiotic combinations, providing standardized placement for accurate zone diameter measurement.

Usage Guidelines

To operate, insert up to six BD Sensi-Disc cartridges into the dispenser. Hold the dispenser perpendicular to the agar plate and press the release mechanism to simultaneously dispense the discs onto the inoculated surface. Ensure even contact between the dispenser and the agar surface to maintain consistent spacing and placement accuracy. After dispensing, replace cartridge caps promptly to preserve disc potency. Clean the dispenser regularly with a mild disinfectant and ensure it is fully dry before reuse. Avoid immersing the device in liquid or exposing it to excessive heat.

Certifications, Safety Standards, and Regulatory Approvals

The BD Sensi-Disc 6-Place Dispenser is manufactured under ISO 13485:2016-certified quality management systems and complies with CLSI (Clinical and Laboratory Standards Institute) and FDA standards for antimicrobial susceptibility testing devices. It is CE-marked for in vitro diagnostic (IVD) use in laboratories worldwide. Each unit is quality tested for mechanical precision, alignment accuracy, and compatibility with BD Sensi-Disc cartridges to ensure reliable, reproducible operation in diagnostic testing environments.

Comparison with Competitor Products

Compared to manual or single-disc placement methods, the BD 260661 Dispenser offers faster operation and superior accuracy. While competitor models may vary in disc alignment or mechanical reliability, BDs dispenser ensures precise placement with minimal disc overlap or misalignment. Its ergonomic design and sturdy build outperform low-cost alternatives that may cause uneven dispensing. Additionally, BDs dispenser integrates perfectly with BDs proprietary Sensi-Disc cartridges, ensuring dependable performance and consistent antibiotic delivery in AST testing.

Typical User Profile and Application Scenarios

This product is designed for laboratory professionals, microbiologists, and technicians conducting antibiotic susceptibility testing. Typical users and scenarios include:

  • Clinical labs performing daily susceptibility tests on bacterial isolates.
  • Public health labs conducting resistance trend analyses.
  • Research facilities evaluating novel antibiotics or bacterial strains.
  • Academic institutions teaching microbiology laboratory techniques.

The BD 260661 Dispenser is a standard tool in microbiology labs focused on accuracy, speed, and reproducibility in disc diffusion testing.

Best Practices for Use and Maintenance

Store the dispenser in a clean, dry environment when not in use. Always handle with clean gloves to maintain sterility. Avoid exposing the device to corrosive chemicals or high temperatures. Periodically inspect mechanical parts for smooth function and alignment. Clean external surfaces with a soft cloth and mild detergentdo not autoclave or immerse. Ensure all cartridges are stored in airtight containers with desiccants to preserve antibiotic potency. Replace the dispenser if dispensing pressure or alignment becomes inconsistent over time.

Regulatory and Safety Information

The BD 260661 - BD Sensi-Disc 6-Place Dispenser complies with FDA, CE, and ISO regulations for in vitro diagnostic laboratory accessories. It is made of non-toxic, non-pyrogenic materials suitable for clinical use. The device contains no hazardous substances and requires no special disposal procedures. A product specification sheet and user manual are available from BD upon request. Use only with compatible BD Sensi-Disc cartridges to ensure optimal performance and test validity.

How to Order

To order the BD 260661 - BD Sensi-Disc 6-Place Dispenser, add the item to your cart and complete checkout through CIA Medical. We offer competitive pricing, fast delivery, and full customer support for hospitals, laboratories, and re