BD 2652034 - PowerLoc PAK Safety Infusion Set, 20G x 0.75", Without Y-Injection Site, 5/CS (Temp Sensitive; Non-Returnable) (Continental US Only)

BD  # 2652034 - PowerLoc PAK Safety Infusion Set, 20G x 0.75
Part Number BD 2652034
SKU Number CIA8043490
Sell Unit CASE
Ships Within Special Order
List Price $235.43
Enter a valid quantity
Product Description

BD 2652034 - PowerLoc PAK Safety Infusion Set, 20G x 0.75", Without Y-Injection Site, 5/CS (Temp Sensitive; Non-Returnable) (Continental US Only)

The BD 2652034 PowerLoc PAK Safety Infusion Set is a sterile, single-use port-access solution designed for accessing compatible surgically implanted vascular ports. The set features a 20-gauge non-coring needle with a 0.75-inch length and is configured without a Y-injection site, providing a streamlined direct fluid pathway for compatible infusion and vascular-access procedures.

The PowerLoc system supports administration of compatible fluids and medications, blood specimen collection, implanted port flushing, and power injection through appropriately rated vascular access systems. The 20-gauge configuration offers a practical balance between needle diameter and flow capability for a broad range of infusion therapy and diagnostic imaging applications.

The 0.75-inch needle length is designed for implanted ports positioned relatively close to the skin surface. Proper needle-length selection helps ensure complete septum access while supporting stable positioning, a low access profile, effective dressing application, and patient comfort.

The corresponding 20-gauge x 0.75-inch PowerLoc configuration without a Y-site has an approximate priming volume of 0.3 mL. The absence of a Y-injection site creates a direct tubing pathway that may be preferred when secondary medication or fluid access through the infusion set is not required.

An integrated safety mechanism is designed to help reduce accidental needlestick exposure during port deaccessing. The safety design helps shield and secure the needle point after removal, supporting safer handling and disposal practices.

The PowerLoc platform features a small footprint, low-profile construction, lightweight design, good access-site visibility, and compatibility with appropriate dual-lumen implanted ports. The PAK presentation provides an organized solution intended to simplify the multi-step sterile preparation process for implanted port access. BD 2652034 is supplied five sets per case.

Key Benefits

  • 20-gauge non-coring needle supports access to compatible surgically implanted vascular ports.
  • 0.75-inch needle length accommodates appropriately positioned superficial implanted ports.
  • Power-injectable design supports compatible contrast-enhanced diagnostic imaging procedures.
  • Compatible 20-gauge PowerLoc configurations support power-injection flow rates up to 5 mL per second when the complete system is appropriately rated.
  • Configuration without a Y-injection site provides a streamlined direct fluid pathway.
  • Approximate 0.3 mL priming volume helps support fluid-management planning.
  • Non-coring needle design helps minimize unnecessary damage to the implanted port septum during appropriate access.
  • Integrated safety mechanism helps protect the needle following port deaccessing.
  • Safety design supports occupational needlestick-prevention practices.
  • Low-profile construction helps facilitate dressing application and access-site management.
  • Small footprint supports visibility around the implanted port access site.
  • Lightweight design helps reduce unnecessary bulk at the access site.
  • Compatible with appropriate dual-lumen implanted port applications.
  • Suitable for compatible infusion therapy, blood sampling, port maintenance, and power-injection workflows.
  • PAK configuration helps organize components used during sterile port-access preparation.
  • Five-per-case packaging supports efficient clinical inventory management.

Compatibility and Applications

The BD 2652034 PowerLoc PAK Safety Infusion Set is intended for use with compatible surgically implanted vascular access ports designed to accept non-coring port-access needles.

Potential clinical applications include chemotherapy administration, antibiotic therapy, hydration, parenteral nutrition, blood product administration, long-term infusion therapy, blood specimen collection, implanted port flushing, and contrast-media delivery during compatible diagnostic imaging procedures.

The 20-gauge configuration may be selected when moderate-to-high flow capability is required while maintaining a smaller needle diameter than a 19-gauge access device. Selection should consider the prescribed medication or solution, viscosity, desired flow rate, implanted port specifications, infusion equipment, imaging requirements, and professional clinical judgment.

The 0.75-inch needle length is generally suitable for implanted ports located relatively close to the skin surface. A needle that is too short may not completely enter the port septum, while unnecessary additional needle length may affect stability, securement, and dressing placement.

Because BD 2652034 does not include a Y-injection site, it provides a direct fluid pathway without an integrated secondary access point. This configuration may be appropriate when the planned therapy uses a single primary connection and does not require intermittent access through a Y-site.

For power injection, the implanted port, access needle, tubing, connectors, extension components, and every other device within the complete fluid pathway must be specifically rated for the intended procedure. The lowest-rated component determines the maximum allowable pressure and flow rate.

Compatibility should be confirmed with the exact implanted port model, septum design, tissue depth, prescribed therapy, infusion pump, power injector, connector system, dressing materials, and institutional vascular-access procedures.

Usage Guidelines

The BD 2652034 should be used only by healthcare professionals trained and authorized to access implanted vascular ports. Current manufacturer instructions, aseptic technique, institutional procedures, and the implanted port manufacturer's directions should be followed throughout the procedure.

  • Confirm the patient's identity, prescribed therapy, implanted port type, and power-injection status when applicable.
  • Assess the location and depth of the implanted port before selecting the 0.75-inch needle.
  • Verify that the 20-gauge configuration is appropriate for the intended infusion or imaging procedure.
  • Confirm that a configuration without a Y-injection site is suitable for the planned clinical workflow.
  • Inspect the sterile package for punctures, moisture, damage, contamination, or compromised integrity.
  • Prepare the implanted port site according to institutional skin-antisepsis and sterile-access procedures.
  • Prime the complete infusion pathway with an approved solution before accessing the port.
  • Remove air from the fluid pathway before connection to the implanted vascular port.
  • Stabilize the implanted port and insert the non-coring needle perpendicular to the septum using an approved technique.
  • Advance the needle carefully until appropriate access to the port reservoir is achieved.
  • Verify correct placement according to institutional policy, including aspiration for blood return when clinically appropriate.
  • Flush the implanted port according to current manufacturer instructions and facility protocol.
  • Position and secure the tubing to minimize pulling, twisting, pressure, and dressing disruption.
  • Apply an approved sterile dressing while maintaining appropriate access-site visibility.
  • Monitor the site for pain, swelling, redness, leakage, displacement, or other abnormalities throughout therapy.
  • Confirm power-injection eligibility before connecting the access system to a power injector.
  • Do not exceed 5 mL per second or the lower operating limit of any component within the complete system.
  • After therapy, flush and lock the implanted port according to the prescribed protocol.
  • Stabilize the port while withdrawing the needle and activating the integrated safety mechanism.
  • Confirm that the needle is fully secured in the protective position before further handling.
  • Dispose of the used device immediately in an approved sharps container.

Stop the procedure and assess the vascular-access system if unexpected resistance occurs during flushing, appropriate blood return cannot be obtained when expected, the patient experiences unusual discomfort, or swelling, leakage, displacement, or another abnormality develops at the port site.

Certifications and Safety Standards

The BD 2652034 PowerLoc PAK Safety Infusion Set is intended for professional medical use within established vascular-access, infusion-therapy, diagnostic imaging, infection-prevention, and occupational safety programs.

The device should be incorporated into facility procedures addressing implanted port assessment, hand hygiene, sterile-field preparation, skin antisepsis, port access, infusion administration, dressing management, power injection, deaccessing, and sharps disposal.

The integrated safety mechanism is designed to help protect the needle point following removal from the implanted port. This safety feature supports needlestick-prevention practices but does not replace appropriate clinician training, personal protective equipment, safe sharps handling, exposure-control procedures, or immediate disposal in an approved sharps container.

The non-coring needle is designed for accessing compatible implanted vascular port septa while helping minimize unnecessary septum damage during appropriate use. Needle gauge and length should be selected according to patient anatomy, port depth, prescribed therapy, required flow characteristics, and current manufacturer instructions.

Manufacturer information for the corresponding 20-gauge x 0.75-inch PowerLoc configuration without a Y-site lists ethylene oxide sterilization and indicates that natural rubber latex and DEHP are not part of the material formulation. Healthcare facilities should verify the current packaging, labeling, and product-specific documentation for BD 2652034 before relying on these characteristics for procurement or clinical decisions.

Healthcare organizations should review current manufacturer documentation for applicable FDA status, UDI information, sterilization details, material composition, shelf life, pressure limitations, flow-rate specifications, contraindications, warnings, precautions, and other regulatory or technical requirements.

Comparison with Competitors

Compared with conventional implanted port needles without integrated safety technology, the BD PowerLoc platform incorporates a safety mechanism designed to help shield the needle after deaccessing. This can help reduce accidental needlestick exposure between needle removal and final sharps disposal.

Compared with PowerLoc configurations containing a Y-injection site, BD 2652034 provides a direct fluid pathway without an additional secondary access point. This may simplify the tubing configuration when secondary medication or fluid administration through a Y-site is not required.

Compared with non-power-injectable port-access needles, the PowerLoc platform supports compatible power-injection procedures when used with an appropriately rated implanted port and complete fluid pathway.

Compared with a 19-gauge PowerLoc needle, the 20-gauge configuration provides a smaller external diameter while retaining power-injection capability up to 5 mL per second under applicable conditions. Compared with a 22-gauge configuration, the 20-gauge option provides greater maximum flow capability for procedures requiring higher flow rates.

Compared with 1-inch and 1.5-inch access needles, the 0.75-inch configuration offers a lower access profile for implanted ports positioned closer to the skin surface. Correct needle-length selection supports complete septum access, stability, securement, and effective dressing placement.

Compared with loose individual port-access supplies, the PAK presentation provides an organized solution for the multi-step sterile preparation process. This can help simplify supply preparation and support procedural consistency across clinical teams.

Alternative safety infusion sets may vary in gauge, needle length, power-injection capability, safety activation method, tubing design, Y-site availability, priming volume, included kit components, and packaging quantity. BD 2652034 combines a 20-gauge, 0.75-inch non-coring needle with a direct no-Y-site configuration, power-injection capability, integrated safety technology, and organized PAK presentation.

Typical User Profile and Application Scenarios

The BD 2652034 PowerLoc PAK Safety Infusion Set is intended for trained healthcare professionals responsible for accessing and managing implanted vascular ports. Typical users include infusion nurses, oncology nurses, radiology nurses, vascular-access specialists, physicians, advanced practice clinicians, and other qualified healthcare personnel.

Common use environments include hospitals, oncology centers, outpatient infusion clinics, diagnostic imaging departments, ambulatory treatment centers, emergency departments, specialty practices, and other healthcare facilities where implanted vascular ports are routinely accessed.

The product may be selected for patients whose implanted port can be appropriately accessed with a 0.75-inch needle and whose prescribed therapy or diagnostic procedure is compatible with a 20-gauge access device.

Typical application scenarios include chemotherapy administration, antibiotic infusion, hydration, parenteral nutrition, blood product administration, blood specimen collection, routine implanted port maintenance, and power injection of contrast media during compatible imaging procedures.

The configuration without a Y-injection site is particularly relevant for clinical workflows using a direct primary connection that do not require a secondary access point within the infusion tubing.

Best Practices for Use and Maintenance

The BD 2652034 is a sterile, single-use medical device and does not require maintenance as reusable equipment. Best practices focus on proper storage, accurate product selection, sterile preparation, implanted port access, site monitoring, power-injection verification, safety activation, and disposal.

  • Store unopened sets according to manufacturer-recommended environmental conditions.
  • Protect packages from moisture, excessive temperature, crushing, punctures, and contamination.
  • Rotate inventory according to expiration dates and facility stock-control procedures.
  • Verify the BD 2652034 catalog number before opening the package.
  • Confirm the 20-gauge size, 0.75-inch needle length, and configuration without a Y-injection site.
  • Assess the patient's tissue depth and implanted port position before selecting the needle length.
  • Confirm that the prescribed therapy, fluid characteristics, and required flow rate are appropriate for a 20-gauge access device.
  • Use strict aseptic technique during preparation, priming, insertion, connection, and dressing application.
  • Prime the complete fluid pathway before accessing the implanted vascular port.
  • Consider the approximately 0.3 mL priming volume when managing fluid volume in clinically sensitive situations.
  • Stabilize the implanted port during both needle insertion and removal.
  • Position the tubing to minimize pulling, twisting, or pressure at the access site.
  • Monitor the implanted port site and tubing connections throughout therapy.
  • Verify that the entire vascular-access system is approved for power injection before any powered procedure.
  • Never exceed the lowest pressure or flow-rate limit of any component within the complete system.
  • Do not bend, cut, modify, repair, or otherwise alter the infusion set.
  • Do not reuse, clean, resterilize, or reprocess the single-use device.
  • Confirm complete safety activation immediately after needle withdrawal.
  • Place the protected device directly into an approved sharps container.

Regulatory and Safety Information

The BD 2652034 PowerLoc PAK Safety Infusion Set should be used only by appropriately trained healthcare professionals and only for applications consistent with current manufacturer labeling, implanted port instructions, professional clinical judgment, and institutional policy.

Before use, verify the product identity, 20-gauge size, 0.75-inch needle length, no-Y-site configuration, sterile package integrity, expiration date, and compatibility with the implanted vascular port. Do not use a device that is expired, damaged, contaminated, or supplied in compromised packaging.

The set should not be used for power injection unless the implanted port and every component within the complete fluid pathway are specifically rated for the intended procedure. Permitted pressure, flow rate, contrast-media characteristics, and other operating conditions must be confirmed before use.

Compatible 20-gauge PowerLoc configurations support power injection up to 5 mL per second under applicable manufacturer-specified conditions. The lowest-rated component within the complete vascular-access system determines the maximum allowable operating limit.

Incorrect needle-length selection, incomplete septum access, excessive pressure, needle displacement, or improper securement may contribute to infiltration, extravasation, leakage, tissue injury, implanted port damage, interrupted therapy, or other complications.

Because BD 2652034 does not include a Y-injection site, it does not provide a secondary access point within the tubing. Clinical teams should confirm that a direct fluid pathway meets the requirements of the planned therapy before opening the package.

The integrated safety mechanism should be activated according to current manufacturer instructions. The device remains a contaminated sharp following deaccessing and should be discarded immediately in an approved sharps container.

BD 2652034 is supplied five sets per case with a minimum order quantity of one case according to the manufacturer listing. Purchasing personnel should confirm current availability, storage requirements, shipping eligibility, order quantity, and applicable return conditions before purchasing.

How to Order

Select the BD 2652034 - PowerLoc PAK Safety Infusion Set without Y-Injection Site, 20G x 0.75" and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.