BD 305214 - Needle, 18G x 1", Admixture Nokor Vented, Sterile Shelf Pack, 100/BX, 10BX/CASE

BD  # 305214 - Needle, 18G x 1
Part Number BD 305214
SKU Number CIA7023424
Sell Unit CASE
Ships Within Special Order
List Price $960.38
Enter a valid quantity
Product Description

BD 305214 - Needle, 18G x 1", Admixture Nokor Vented, Sterile Shelf Pack, 100/BX, 10BX/CASE

The BD 305214 Admixture Nokor Vented Needle is a sterile 18G x 1" needle designed specifically for safe and efficient medication admixture, vial access, and solution transfer. Featuring BDs Nokor vented technology, this needle includes an integrated air filter that allows air to enter the vial while preventing aerosolized drug or contaminants from escaping. This improves safety during reconstitution and medication withdrawal, especially with powdered or volatile drugs. The 18G diameter supports rapid fluid transfer while the beveled design ensures smooth vial penetration.

Manufacturer305214
ApplicationVented Needle
Gauge18 Gauge
Length1 Inch
Needle Point StyleAnti-Coring Bevel
TypeVented

Key Benefits

The vented design helps equalize vial pressure, reducing splashback and aerosolization risks during withdrawal or reconstitution. This enhances safety for clinicians, particularly when handling hazardous or high-pressure medications. The 18G bore allows efficient aspiration and transfer of thicker solutions. The needles rugged Nokor construction prevents coring, preserving vial integrity and reducing particulate contamination. As a sterile, single-use needle, it supports infection prevention and consistent medication preparation quality.

Compatibility and Applications

This vented admixture needle is compatible with standard Luer-Lok and Luer-slip syringes. It is commonly used for:

  • Medication reconstitution
  • Transferring solutions from vials to syringes or IV bags
  • Withdrawing powdered medications requiring pressure equalization
  • Compounding in pharmacy clean rooms
  • Preparing hazardous drugs under USPcontainment procedures

It is commonly used in hospital pharmacies, infusion centers, operating rooms, and oncology medication preparation environments.

Usage Guidelines

Attach the needle securely to a sterile syringe. Insert the needle into the medication vial, ensuring the vented portion remains unobstructed. Allow filtered air to enter the vial naturally to equalize pressure and prevent spray-back. Withdraw or reconstitute medication as needed. Do not use for direct patient injectionthis needle is intended for admixture only. Dispose of immediately in a sharps container after use.

Certifications, Safety Standards, and Regulatory Approvals

The BD 305214 needle meets ISO and FDA standards for sterile single-use medical needles. The integrated venting filter supports USPandsterile compounding safety practices. BDs quality control ensures consistent needle sharpness, vent functionality, and sterility throughout shelf-pack storage.

Comparison with Competitor Products

Competitor admixture needles often lack specialized venting systems or rely on less effective air-access mechanisms. The Nokor vented design provides superior aerosol protection and more reliable pressure equalization. BDs anti-coring bevel and consistent manufacturing quality help reduce particulate contamination compared to lower-cost alternatives.

Typical User Profile and Application Scenarios

This product is widely used by pharmacists, pharmacy technicians, anesthesiologists, nurses, and compounding specialists. It is ideal for environments where medication safety, contamination control, and precise solution handling are essential, including sterile compounding clean rooms, infusion pharmacies, and hospital medication preparation areas.

Best Practices for Use and Maintenance

Use only for vial access, not for patient injection. Ensure the vent is not blocked during use. Follow aseptic technique throughout medication preparation. Always verify vial contents and compatibility before reconstitution. Dispose of used needles immediately in approved sharps containers to prevent injury and contamination.

Regulatory and Safety Information

This needle is intended for single-use only and must not be reprocessed or reused. It complies with OSHA and CDC guidelines for safe handling of sharps and hazardous drugs. The integrated filter reduces exposure risk from aerosolized drug particles.

How to Order

To order the BD 305214 Admixture Nokor Vented Needle (18G x 1", Sterile Shelf Pack), add the product to your cart and complete checkout on the CIA Medical website. For bulk orders, pharmacy supply planning, or assistance selecting compatible admixture tools, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page.