Product Description

BD 305541 - Allergist Tray, 1mL Syringe with Permanently Attached Needle, 27G x 3/8", Intradermal Bevel, 25/TRAH, 40 TRAYS/CS (80 cs/plt) (Continental US Only)

The BD 305541 Allergist Tray features a sterile, single-use 1mL syringe equipped with a permanently attached 27G x 3/8" intradermal bevel needle designed for high-precision allergen testing and intradermal injections. This tray is engineered to support accurate dosing, controlled delivery, and consistent skin-test placementcritical requirements for allergy specialists, dermatologists, and clinicians performing diagnostic intradermal procedures. The permanently attached needle minimizes dead space and enhances dose accuracy, while BDs fine-gauge, sharp intradermal bevel ensures smooth penetration and reliable wheal formation.

Manufacturer305541
ApplicationStandard Allergy Tray
Gauge27 Gauge
Needle Length3/8 Inch
Needle StyleAttached Needle
UsageDisposable

Key Benefits

The BD 305541 syringe and needle combination provides exceptional control and accuracy for allergen extracts and intradermal medications. The ultra-fine 27G needle reduces discomfort during superficial skin injections and supports consistent intradermal placement. The permanently attached needle eliminates Luer connection variability, reducing dead space and ensuring precise dosingvital in allergy testing where minute volumes must be controlled. The 1mL syringe barrel includes clear, bold graduations for accurate measurement, supporting reliable, repeatable clinical results.

Compatibility and Applications

This allergist tray is compatible with standard skin testing workflows and allergen extract vials. It is widely used for intradermal allergy testing, tuberculin testing, local anesthetic infiltration, and small-volume diagnostic injections. The product is a preferred tool in allergist practices, dermatology clinics, primary care settings, pulmonary labs, and immunology departments where controlled intradermal delivery is essential.

Usage Guidelines

Draw the required allergen extract or medication using aseptic technique. Hold the syringe at a low angle and insert the needle bevel-up into the superficial dermis. Deliver the precise volume needed to create an appropriate wheal for testing purposes. Avoid injecting too deeply to maintain intradermal placement. Dispose of the syringe immediately after use in an approved sharps container; the device is single-use only and not designed for reuse or detachment of the needle.

Certifications, Safety Standards, and Regulatory Approvals

The BD 305541 tray is produced under strict quality controls and complies with regulatory requirements for sterile, single-use injection devices. The permanently attached needle meets safety and sterility standards for intradermal applications. BDs manufacturing process ensures consistent sharpness, structural integrity, and dose accuracy to support safe allergy testing and diagnostic procedures.

Comparison with Competitor Products

Compared to generic intradermal syringes, the BD 305541 offers superior bevel sharpness, clearer graduations, and more consistent dosing due to its fixed-needle design. Competitor products may introduce dead-space variability or lack the precision needed for allergen testing. BDs long-standing reputation for high-quality needles and syringes makes this tray a trusted choice for clinicians requiring reliable intradermal performance.

Typical User Profile and Application Scenarios

This product is used by allergists, dermatologists, immunologists, nurses, and primary care clinicians trained in intradermal injection techniques. It is ideal for allergy testing panels, vaccine sensitivity testing, tuberculin screening, and specialty diagnostic injections requiring precise, low-volume delivery. Its fine-gauge design makes it suitable for pediatric and adult patients.

Best Practices for Use and Maintenance

Maintain aseptic handling when preparing allergen extracts. Verify proper bevel orientation for correct intradermal placement. Inject slowly to ensure accurate wheal formation. Never attempt to detach or reuse the needle. Dispose of the unit immediately in a sharps container after use. Store trays in a clean, dry environment and inspect packaging integrity before opening.

Regulatory and Safety Information

The BD 305541 complies with OSHA sharps handling guidelines and sterile injection safety standards. Its single-piece construction reduces the risk of needle detachment or medication dosing error. Clinicians must follow institutional protocols for intradermal injections, biohazard disposal, and allergy testing documentation.

How to Order

To order the BD 305541 Allergist Tray with 1mL syringe and permanently attached 27G x 3/8" intradermal needle, add the item to your cart and complete the secure checkout process on the CIA Medical website. For bulk allergy clinic orders, supply chain planning, or product selection support, contact CIA Medical customer service at (312) 275-5850 or submit an inquiry through the contact form on this page. Our team is ready to assist with high-volume procurement for allergy and immunology practices.