-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
BD 365992 - Vacutainer Glucose Tube (NGMBT) Sodium Fluoride/Potassium Oxalate Tube for Accurate Blood Glucose Testing, 50/BX, 4 BX/CS (Temp Sensitive; Non-Returnable) (Continental US Only)
The BD 365992 Vacutainer Glucose Tube (NGMBT) is a high-precision blood collection tube specifically designed for glucose determination and other glycolysis-inhibited assays. Manufactured by BD (Becton Dickinson), this sterile tube contains a combination of sodium fluoride and potassium oxalate additives that effectively preserve glucose levels in collected blood by inhibiting glycolytic enzyme activity. The NGMBT (No Gel, Manual Blood Tube) format is ideal for laboratory professionals requiring precise and reliable glucose measurements in clinical chemistry testing. The BD 365992 tube ensures optimal sample stability and accuracy from collection to analysis, supporting consistent diagnostic outcomes.
| Manufacturer | 365992 |
| Application | Capillary Blood Collection Tube |
| Material | Plastic Tube |
| Tube Color | Translucent Tube |
| Tube Material | Plastic |
Key Benefits
The BD 365992 Glucose Tube provides accurate glucose results by preventing post-collection glycolysis, which can otherwise reduce glucose concentrations in the specimen. Sodium fluoride acts as a glycolytic inhibitor, while potassium oxalate functions as an anticoagulant, preserving sample integrity during handling and transport. The tubes precision-engineered vacuum ensures consistent fill volumes, while the BD Hemogard closure enhances safety by minimizing the risk of exposure to bloodborne pathogens. The clear tube body allows easy visual inspection of the sample, and the stable additive formulation supports extended storage before testing.
Compatibility and Applications
The BD 365992 Glucose Tube is compatible with standard BD Vacutainer needles, holders, and centrifugation systems. It is primarily used in clinical chemistry laboratories for glucose analysis and lactate determination. Common applications include fasting blood glucose testing, glucose tolerance tests (GTT), diabetes screening, and monitoring of hypoglycemic or hyperglycemic conditions. The tube is suitable for both hospital-based and outpatient laboratory settings where accurate blood glucose measurement is critical.
Usage Guidelines
Perform venipuncture using standard collection procedures and allow the tube to fill to the designated volume. Immediately after collection, gently invert the tube 810 times to ensure complete mixing of blood with the sodium fluoride/potassium oxalate additives. Do not shake vigorously to avoid hemolysis. Centrifuge the sample according to laboratory protocol (typically within 30 minutes of collection) to separate plasma or serum for analysis. The stabilized sample can be stored refrigerated at 28C if testing is delayed. Always use aseptic technique and handle all specimens as potentially infectious materials.
Certifications, Safety Standards, and Regulatory Approvals
The BD 365992 Vacutainer Glucose Tube complies with ISO 13485 and ISO 9001 quality management standards and meets FDA and CE regulatory requirements for in vitro diagnostic (IVD) devices. It is manufactured under Good Manufacturing Practices (GMP) and validated for consistent vacuum draw, additive concentration, and glucose preservation efficiency. BDs rigorous quality control processes ensure accurate performance, reproducibility, and safety for clinical diagnostic use.
Comparison with Competitor Products
Compared to standard blood collection tubes without glycolytic inhibitors, the BD 365992 Glucose Tube provides superior stability and reliability for glucose assays. While competitor tubes may allow glycolysis to continue post-collection, leading to falsely low glucose readings, BDs sodium fluoride/potassium oxalate formulation ensures accurate, time-independent glucose measurement. The Hemogard closure offers enhanced user safety compared to conventional rubber stoppers, and BDs precision vacuum system ensures reproducible sample volumes for dependable testing outcomes.
Typical User Profile and Application Scenarios
This product is intended for use by clinical laboratory technologists, phlebotomists, and healthcare professionals performing blood glucose or lactate testing. It is ideal for use in hospitals, outpatient clinics, reference laboratories, and research facilities conducting metabolic and biochemical analyses. The BD 365992 tube is also suitable for use in endocrinology studies and diabetes management programs requiring consistent and reliable blood glucose evaluation.
Best Practices for Use and Maintenance
Store the tubes at 425C in a dry, stable environment. Avoid exposure to direct sunlight or excessive heat that could affect vacuum performance. Always check the tube for cracks, leaks, or loss of vacuum prior to use. After blood collection, ensure proper mixing of additives to prevent clotting or sample degradation. Label tubes immediately to maintain patient identification accuracy. Dispose of used tubes in accordance with institutional biosafety and sharps waste regulations. Never attempt to reuse or reseal used tubes.
Regulatory and Safety Information
This device is intended for professional use only. Handle all blood specimens under Biosafety Level 2 (BSL-2) protocols. Use appropriate personal protective equipment (PPE), including gloves, lab coats, and face protection, during collection and handling. Avoid recapping, bending, or breaking tubes manually. Refer to the products Instructions for Use (IFU) and Safety Data Sheet (SDS) for detailed handling and disposal information. BD ensures compliance with global safety, environmental, and quality regulations for clinical consumables.
How to Order
To purchase the BD 365992 Vacutainer Glucose Tube (NGMBT), add the product to your cart and complete the secure checkout process on the CIA Medical website. For institutional or bulk orders, contact CIA Medical customer service at (312) 275-5850 or use the online inquiry form. CIA Medical provides competitive pricing, fast shipping, and expert support for all BD Vacutainer blood collection and clinical chemistry products.