(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 366704 - Plastic Serum Tube, BD Vacutainer Plus, 13mm x 75mm, 3.0mL, Red/Gray Conventional Closure, No Additive, 100/BX, 10 BX/CS (Temp Sensitive; Non-Returnable) (Continental US Only)

BD  # 366704 - Plastic Serum Tube, BD Vacutainer Plus, 13mm x 75mm, 3.0mL, Red/Gray Conventional Closure, No Additive, 100/BX, 10 BX/CS (Temp Sensitive; Non-Returnable) (Continental US Only)
Part Number BD 366704
SKU Number CIA8041290
Sell Unit CASE
Ships Within Special Order
List Price $371.61
Enter a valid quantity
Product Description

BD 366704 - Plastic Serum Tube, BD Vacutainer Plus, 13mm x 75mm, 3.0mL, Red/Gray Conventional Closure, No Additive, 100/BX, 10 BX/CS (Temp Sensitive; Non-Returnable) (Continental US Only)

The BD 366704 Plastic Serum Tube is a 13mm x 75mm, 3.0mL BD Vacutainer Plus tube designed for serum collection and routine laboratory testing. Featuring a red/gray conventional closure and no additive, this tube supports natural clot formation for clear serum separation. The plastic construction provides durability and reduced breakage risk compared to traditional glass tubes, making it a safer option for clinical environments. The paper label allows accurate sample identification, supporting traceability throughout the testing process. Its reliable, additive-free design makes it ideal for a wide range of chemistry, immunology, and serology assays.

Manufacturer366704
ApplicationSecondary Tube
Dimensions13 X 75 mm
MaterialPlastic Tube
SterilitySterile
Tube MaterialPlastic

Key Benefits

This serum tube offers several advantages for general laboratory use. The absence of additives allows blood to clot naturally, producing a clean serum specimen ideal for routine tests. The red/gray closure provides a secure seal to maintain sample integrity during handling and centrifugation. Plastic construction reduces the risk of sharps injuries and breakage while improving transport safety. The 3.0mL volume is suitable for both pediatric and adult collections where smaller sample sizes are acceptable, improving patient comfort during venipuncture.

Compatibility and Applications

The BD 366704 tube is compatible with standard BD Vacutainer blood collection systems and laboratory centrifuges. It is commonly used for serum-based testing including general chemistry panels, liver function tests, metabolic panels, immunoassays, infectious disease screening, hormone testing, and other diagnostic assays requiring serum. Clinical settings include hospital laboratories, outpatient clinics, physician offices, emergency departments, and reference laboratories.

Usage Guidelines

Collect the sample using standard venipuncture technique. Allow the blood to clot fully before centrifugation; recommended clot time is typically 30 minutes unless otherwise specified by your laboratory. Do not invert the tube excessively, as no additive is present. After clot formation, centrifuge according to laboratory protocols to obtain clear serum. Ensure the closure is fully seated during transport to prevent leakage or contamination.

Certifications, Safety Standards, and Regulatory Approvals

The BD 366704 serum tube meets regulatory requirements for sterile, single-use blood collection devices. BDs manufacturing process ensures consistent tube performance, closure integrity, and label quality. The product complies with laboratory safety guidelines for specimen integrity, material strength, and reliable centrifugation performance.

Comparison with Competitor Products

Compared to generic no-additive serum tubes, BDs Vacutainer Plus line offers superior durability, more consistent specimen quality, and better closure performance. Competitor tubes may demonstrate variable clotting behavior, inconsistent cap integrity, or increased risk of breakage. BDs strong global reputation in specimen collection makes this tube a preferred choice for high-volume and precision-driven laboratory environments.

Typical User Profile and Application Scenarios

This tube is used by phlebotomists, laboratory technicians, nurses, and clinical assistants involved in routine blood collection. It is ideal for general chemistry testing, serologic screening, endocrine evaluations, and diagnostic panels requiring clear serum. Its smaller volume is well suited for pediatric draws, geriatric patients, or situations requiring minimal blood collection.

Best Practices for Use and Maintenance

Inspect each tube for cracks or defects before use. Fill to the recommended volume to maintain proper serum-to-cell ratio. Allow sufficient clotting time to ensure sample clarity. Handle with care during centrifugation to protect tube integrity. Store tubes at room temperature and avoid prolonged exposure to heat or cold. Dispose of used tubes as biohazard waste according to facility protocols.

Regulatory and Safety Information

The BD 366704 tube complies with OSHA and laboratory biosafety standards for blood specimen handling. The plastic material reduces injury risk, and the conventional closure helps maintain a clean, secure sample environment. Users must follow institutional guidelines for blood collection, transport, centrifugation, and disposal.

How to Order

To order the BD 366704 Plastic Serum Tube, BD Vacutainer Plus, 3.0mL Red/Gray Conventional Closure, add the item to your cart and proceed through the secure checkout on the CIA Medical website. For bulk laboratory orders, supply chain guidance, or product comparison support, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page. Our team is ready to support high-volume diagnostic laboratories and clinical testing facilities.