(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 369741 - Glass Blood Collection Tube 2.4 mL Buffered Sodium Citrate 3.8%, 13 x 75 mm, Black Hemogard Closure, 100/PK, 10 PK/CS (Minimum Expiry Lead is 90 days) (Temp Sensitive; Non-Returnable) (Continental US Only)

BD  # 369741 - Glass Blood Collection Tube 2.4 mL Buffered Sodium Citrate 3.8%, 13 x 75 mm, Black Hemogard Closure, 100/PK, 10 PK/CS (Minimum Expiry Lead is 90 days) (Temp Sensitive; Non-Returnable) (Continental US Only)
Part Number BD 369741
SKU Number CIA8041304
Sell Unit CASE
Ships Within Special Order
List Price $1,150.45
Enter a valid quantity
Product Description

BD 369741 - Glass Blood Collection Tube 2.4 mL Buffered Sodium Citrate 3.8%, 13 x 75 mm, Black Hemogard Closure, 100/PK, 10 PK/CS (Minimum Expiry Lead is 90 days) (Temp Sensitive; Non-Returnable) (Continental US Only)

The BD 369741 Glass Blood Collection Tube is a specialized venous blood collection tube designed for coagulation-related and erythrocyte sedimentation rate (ESR) testing applications requiring buffered sodium citrate anticoagulant. The tube features a 2.4 mL draw volume, black Hemogard closure, glass construction, and a paper label for specimen identification and laboratory processing.

Each tube contains 0.6 mL of 0.125M (3.8%) buffered sodium citrate solution, which functions as an anticoagulant by binding calcium ions and preventing blood clot formation. This controlled blood-to-additive ratio is essential for maintaining specimen integrity and supporting accurate laboratory testing results.

The Hemogard closure is designed to help minimize blood exposure during handling and processing, while the glass tube construction supports specimen stability and compatibility with validated laboratory workflows.

Manufacturer369741
ApplicationVenous Blood Collection Tube
Closure ColorBlack
Dimensions13 X 75 mm
Tube MaterialGlass

Key Benefits

The BD 369741 provides a precisely measured sodium citrate concentration that supports accurate anticoagulation and specimen preservation for specialized laboratory testing. This helps improve testing reliability and supports consistent diagnostic outcomes.

The black stopper color allows laboratory personnel to quickly identify the tube type and intended application, helping improve workflow efficiency and reduce specimen handling errors.

The Hemogard closure contributes to laboratory safety by helping reduce exposure to blood specimens during collection, transportation, and processing. The paper label provides a reliable surface for patient identification and specimen tracking.

Compatibility and Applications

The BD 369741 is compatible with standard venipuncture equipment, blood collection holders, needles, and laboratory processing systems designed for BD Vacutainer blood collection tubes.

Typical applications include erythrocyte sedimentation rate testing, coagulation-related laboratory procedures, hematology workflows, diagnostic testing, and research applications that require buffered sodium citrate anticoagulated blood specimens.

This product is commonly used in hospitals, clinical laboratories, physician offices, outpatient diagnostic centers, research facilities, and specialty testing laboratories.

Usage Guidelines

Use the BD 369741 according to established blood collection procedures and laboratory protocols. Prior to collection, verify the correct tube selection, expiration date, and specimen requirements.

After blood collection, gently invert the tube according to laboratory guidelines to ensure proper mixing of the blood specimen with the buffered sodium citrate additive. Avoid vigorous shaking, which may affect specimen quality and testing results.

Ensure the tube is filled to the designated draw volume to maintain the proper blood-to-anticoagulant ratio. Underfilling or overfilling may compromise test accuracy.

Label the specimen appropriately and transport it according to facility and laboratory requirements.

Certifications and Safety Standards

The BD 369741 is manufactured under established quality management systems and designed to meet applicable medical device and laboratory specimen collection standards. It is intended to support accurate specimen collection, laboratory performance, and healthcare safety practices.

The Hemogard closure supports workplace safety initiatives by helping reduce blood exposure risks during specimen handling. Healthcare facilities should review current product specifications, labeling, and regulatory documentation before use.

Comparison with Competitor Products

Compared with standard blood collection tubes, the BD 369741 is specifically formulated with buffered sodium citrate for specialized coagulation and ESR-related testing applications. The precisely controlled additive concentration helps support reliable laboratory performance.

Compared with plastic collection tubes, the glass construction may be preferred in certain validated laboratory workflows where glass tubes are specified by protocol or testing requirements.

Compared with conventional closures, the Hemogard closure provides an added safety feature designed to help reduce blood exposure during specimen handling and processing. BD's established reputation in blood collection products further supports confidence in specimen quality and consistency.

Typical User Profile and Application Scenarios

The BD 369741 is commonly used by phlebotomists, nurses, laboratory technicians, clinical laboratory scientists, physicians, hematology specialists, and diagnostic testing personnel involved in blood specimen collection and analysis.

Typical applications include erythrocyte sedimentation rate testing, coagulation studies, hematology laboratory procedures, diagnostic blood collection, hospital laboratory workflows, outpatient testing services, and research projects requiring citrate-anticoagulated specimens.

Best Practices for Use and Maintenance

Store the BD 369741 according to manufacturer recommendations and laboratory inventory procedures. Maintain appropriate environmental conditions and rotate inventory to ensure tubes are used before expiration.

Verify patient identification, specimen requirements, and tube selection before collection. Follow standard venipuncture techniques and laboratory protocols to help maintain specimen integrity.

Ensure proper tube filling and additive mixing immediately after collection. Follow laboratory guidelines for specimen transport, storage, and testing to support accurate results.

Dispose of used tubes and biological materials according to facility policies, bloodborne pathogen regulations, and biomedical waste management requirements.

Regulatory and Safety Information

The BD 369741 is intended for professional healthcare and laboratory use only. Blood collection and specimen handling should be performed by trained personnel following institutional protocols, infection prevention procedures, and applicable healthcare regulations.

Healthcare personnel should use appropriate personal protective equipment, follow bloodborne pathogen safety precautions, and treat all biological specimens as potentially infectious. Proper specimen handling and disposal procedures should always be followed.

How to Order

Select the BD 369741 Glass Tube Hemogard Closure 13 x 75 mm 2.4 mL Buffered Sodium Citrate 0.125M 3.8% Solution Black Stopper and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page.