(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 382612 - Insyte Autoguard IV Catheter 24 Gauge x 3/4 Inch Winged with Blood Control,EACH

BD  # 382612 - Insyte Autoguard IV Catheter 24 Gauge x 3/4 Inch Winged with Blood Control,EACH
Part Number BD 382612
SKU Number CIA7027963
Sell Unit EACH
Ships Within 3-5 Days
List Price Call for Pricing
Product Description

BD 382612 - Insyte Autoguard IV Catheter 24 Gauge x 3/4 Inch Winged with Blood Control,EACH

BD Insyte Autoguard BC Shielded IV Catheter With Blood Control Technology

The BD 382612 Insyte Autoguard IV Catheter 24G x 3/4 Inch with wings and blood control is a safety-engineered peripheral IV catheter designed to support reliable vascular access while helping reduce needlestick injuries and blood exposure. Manufactured byBecton, Dickinson and Company, this catheter integrates BD Autoguard shielding technology with a blood control feature to promote safer, cleaner insertions.

The 24-gauge, 3/4-inch catheter is well suited for patients with small or fragile veins, offering controlled insertion, improved comfort, and dependable performance in routine peripheral IV therapy.

Blood leakage prevention septum

Increased safety

First-stick success

Minimized phlebitis

You do not need to worry about stopping blood during initial insertion with the BD Insyte Autoguard BC catheter.BD Insyte Autoguard IV catheters demonstrated a statistically significant 95% reduction in needlesticks.BD Instaflash needle technology on the 20-G, 22-G and 24-G sizes incorporates a notched needle to improve first-stick success and reduce painful hit-and-miss insertions.BD Vialon biomaterial softens up to 70% in the vein, enabling longer dwell times3 and reducing the chance of mechanical phlebitis by up to 50%
Catalog No. (Non Winged | Winged)
ColorGaugeLength (in)
382512 | 382612Yellow240.75 in.
Catheter ID (mm)Catheter OD(mm)Gravity Flow Rate (mL/min)High Pressure Rating (psi)
0.4826 - 0.55880.6604 - 0.736620N/A

Clean, easy and efficient for clinicians and patients

You strive for a clean IV placement every time, but when you have to apply pressure while activating the devices safety mechanism and connecting the extension, blood spills can happen.

The BD Insyte Autoguard BC shielded IV catheter with blood control technology addresses these challenges:

  • No venous compression required during insertion
  • Less mess and minimized healthcare worker risk resulting from blood leakage
  • Needlestick injury protection
  • Less blood leakage means less disruption during the patients care

Built-in blood leakage prevention

No need to worry about stopping blood during insertion with BD Insyte Autoguard BC catheters.

Stop blood leakage without the need for venous compression - the unique design allows a one-handed insertion technique with blood flow resuming when an add-on device is connected.

Clinically demonstrated to reduce the risk of blood exposure by 95% - reducing staff exposure to blood as well as surface contamination.


Safety at the push of a button

The BD Insyte Autoguard BC catheter is tailored for the clinicians safety and insertion success, leaving you feeling confident in each insertion, and your patients feeling confident in you.

Demonstrated to reduce needlestick injuries by 95%

  • Push-button needle shielding technology
  • Fully encapsulated needle

The right IV catheters, right from the start

BD Vialon Biomaterial

The catheter material is designed to resist kinking and softens up to 70% in the vein, enabling longer dwell times and reducing the chance of mechanical phlebitis by up to 50%.

BD382612 Insyte Autoguard BC Shielded IV Catheter Device Characteristics

What MRI safety information does the labeling contain?Labeling does not contain MRI Safety Information
Device required to be labeled as containing natural rubber latex or dry natural rubber (21 CFR 801.437):No
Device labeled as "Not made with natural rubber latex":No
For Single-Use:Yes
Prescription Use (Rx):Yes
Over the Counter (OTC):No
Kit:No
Combination Product:No
Human Cell, Tissue or Cellular or Tissue-Based Product (HCT/P):No

Key Benefits

The Autoguard safety mechanism automatically shields the needle upon catheter advancement, helping protect clinicians from accidental needlesticks. Integrated blood control technology helps limit blood exposure during insertion, supporting a cleaner work area and improved infection control.

The winged design enhances stabilization and handling during placement, supporting first-attempt success and reducing catheter movement at the site. The 24-gauge size supports gentle access for delicate vasculature while maintaining adequate flow for appropriate therapies.

Compatibility and Applications

The BD Insyte Autoguard catheter is compatible with standard IV administration sets and needleless connectors commonly used in peripheral IV therapy. It integrates easily into established IV insertion and maintenance protocols.

Typical applications include peripheral IV access for medication administration, hydration, and maintenance fluids in pediatric, geriatric, and patients with compromised veins. It is widely used in hospitals, emergency departments, outpatient clinics, and infusion centers.

Usage Guidelines

The catheter should be inserted by trained clinicians using aseptic technique and in accordance with institutional peripheral IV protocols. Proper vein selection and stabilization are important to support successful placement.

After advancement of the catheter, the needle safety mechanism activates automatically. The catheter should be secured and maintained according to facility IV care guidelines. The device is intended for single-patient use.

Certifications, Safety Standards, and Regulatory Approvals

The BD 382612 Insyte Autoguard IV Catheter is manufactured under quality management systems aligned with FDA medical device regulations and internationally recognized manufacturing standards. These controls help ensure sterility, material integrity, and consistent safety mechanism performance.

Regulatory compliance supports use in regulated healthcare environments and reinforces confidence in both patient and clinician safety.

Comparison with Competitor Products

Compared with conventional IV catheters without automatic shielding, the BD Insyte Autoguard offers enhanced sharps protection and reduced blood exposure. While some competitor products rely on manual activation or lack blood control features, this integrated design supports safer, more efficient insertions.

Healthcare facilities often choose BD Insyte Autoguard catheters for their proven safety performance, consistent quality, and alignment with modern IV therapy best practices.

Typical User Profile and Application Scenarios

Typical users include nurses, vascular access specialists, emergency clinicians, and trained healthcare professionals responsible for peripheral IV placement.

The catheter is particularly effective in acute care hospitals, emergency departments, pediatric units, outpatient clinics, and infusion centers where patient comfort and clinician safety are priorities.

Best Practices for Use and Maintenance

Best practice includes confirming the appropriate catheter gauge and length before insertion, maintaining aseptic technique, and ensuring proper stabilization after placement. Routine site assessment and dressing changes help maintain patency and reduce complications.

The catheter should be removed according to institutional guidelines or at the first sign of infiltration, phlebitis, or other complications.

Regulatory and Safety Information

The BD 382612 Insyte Autoguard IV Catheter is classified as a regulated medical device and complies with applicable FDA requirements. Its safety-engineered design supports adherence to OSHA sharps safety guidelines and institutional infection control policies.

Proper training, handling, and ongoing site monitoring are essential to ensure safe, compliant use throughout therapy.

How to Order

The BD 382612 Insyte Autoguard IV Catheter 24 Gauge x 3/4 Inch Winged with Blood Control is available through the CIA Medical website. Add the product to your cart and proceed through the secure checkout process.

For bulk purchasing, vascular access program support, or additional assistance, contact CIA Medical customer service at 312 275 5850 or use the contact form available on this page for prompt support.

Related Products