BD 405140 - Whitacre Spinal Needle 25G x 5", Long Length Pencil-Point for Atraumatic Spinal Access, 50/CASE

BD  # 405140 - Whitacre Spinal Needle 25G x 5
Part Number BD 405140
SKU Number CIA7025655
Sell Unit CASE
Ships Within Special Order
List Price Call for Pricing
Product Description

BD 405140 - Whitacre Spinal Needle 25G x 5", Long Length Pencil-Point for Atraumatic Spinal Access, 50/CASE

The BD 405140 Whitacre Spinal Needle is a 25-gauge, 5-inch (127 mm) single-use spinal access device featuring a pencil-point tip. Designed to provide reliable intrathecal access with minimal trauma, this needle supports atraumatic lumbar punctures and spinal anesthesia procedures. Its extended length is ideal for patients with deeper anatomical landmarks or increased adipose tissue, allowing precision and control during challenging spinal access.

Key Product Features

Hub ColorBlue
Hub MaterialPolypropylene
Hub TypeLuer
Needle Gauge25 G
Needle Gauge (m)0.50 mm
Needle Length (in.)5 in.
Needle Length (m)127.00 mm
Needle Tip TypeWhitacre high-flow pencil point
Needle TypeSpinal
Needle Wall TypeRegular
Total Shelf Life1825
Type Of BevelRegular
SterileSterilized product
Sterilization MethodEO
BPA FreeNot made with BPA
DEHP FreeNot made with DEHP
Latex StatementNot made with natural rubber latex
PVC FreeNot made with PVC
DisposableDisposable product
Single UseProduct is for single use only

Product Packaging Information

Packaging LevelShelfpackCaseEach
Quantity10501
Length293.0 mm305.0 mm
Width58.0 mm302.0 mm
Height58.0 mm77.0 mm
Weight154.8 g774.0 g15.48 g

Key Benefits

  • Whitacre-style pencil-point tip reduces cutting of dura fibers, lowering the risk of post-dural puncture headaches (PDPH)

  • 5" length enables deeper access without compromising rigidity or control

  • 25G diameter provides a balance of minimal invasiveness and stable handling

  • Clear hub for accurate visualization of cerebrospinal fluid (CSF) return

  • Designed for single-use sterile applications, reducing cross-contamination risk

Compatibility and Applications
The BD Whitacre Spinal Needle is compatible with standard luer-lock syringes and introducer needles. It is widely used across various specialties, including:

  • Spinal anesthesia for general, orthopedic, and obstetric surgeries

  • Diagnostic lumbar punctures

  • Intrathecal administration of medications

  • Combined spinal-epidural (CSE) procedures

Usage Guidelines
Use aseptic technique when handling the needle. After positioning the patient (e.g., lateral decubitus or sitting), insert the needle using a controlled, rotational motion. Confirmation of placement is typically achieved by observing CSF flow through the clear hub. Dispose of the needle immediately after use in an approved sharps container.

Certifications, Safety Standards, and Regulatory Approvals
This product is FDA-cleared for spinal use and CE-marked, manufactured under ISO 13485-compliant quality systems. It adheres to AAMI and OSHA standards for safety and sterility and is individually packaged in sterile, latex-free packaging.

Comparison with Competitor Products
Compared to Quincke-type cutting-tip needles, the BD Whitacre needles pencil-point design minimizes trauma to the dura mater. The 5" length provides a significant advantage over standard-length needles in patients with higher BMI or complex spinal anatomy, making this needle a reliable option for clinicians seeking both reach and safety.

Typical User Profile and Application Scenarios
This product is commonly used by anesthesiologists, nurse anesthetists, pain management specialists, and neurologists. It is ideal for use in operating rooms, labor and delivery units, pain clinics, and diagnostic settings where atraumatic spinal access is required.

Best Practices for Use and Maintenance
Store the needle in its original packaging in a cool, dry place. Always check the integrity of the packaging and expiration date before use. Train staff in atraumatic spinal techniques to maximize the clinical benefits of the Whitacre tip. Never reuse the needle; dispose of it immediately after use according to institutional protocol.

Regulatory and Safety Information
The BD 405140 is clearly labeled as single-use, sterile, and latex-free. It is non-pyrogenic and compliant with all required safety and regulatory labeling for use in U.S. and international markets.

How to Order
To purchase the BD 405140 Whitacre Spinal Needle 25G x 5", add the product to your cart and complete checkout through CIA Medicals secure platform. For volume pricing or additional support, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page. Our product experts are available to assist with any clinical or purchasing inquiries.

Related Products