(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD 7617405 - PICC Catheter Tray, Basic, Groshong, Single, 4 FR, 5/cs (Continental US Only)

BD  # 7617405 - PICC Catheter Tray, Basic, Groshong, Single, 4 FR, 5/cs (Continental US Only)
Part Number BD 7617405
SKU Number CIA8043518
Sell Unit CASE
Ships Within Special Order
List Price $1,263.53
Enter a valid quantity
Product Description

BD 7617405 - PICC Catheter Tray, Basic, Groshong, Single, 4 FR, 5/cs (Continental US Only)

The BD 7617405 PICC Catheter Tray is a professional vascular-access system featuring a 4 Fr single-lumen Groshong NXT ClearVue peripherally inserted central catheter in a basic procedural tray configuration. Designed for patients requiring intermediate- to long-term central venous access, the catheter supports compatible infusion therapy, medication administration, nutritional therapy, blood sampling, and other prescribed vascular-access applications.

The catheter is constructed from silicone and incorporates a radiopaque stripe to support visualization during appropriate imaging and placement-confirmation procedures. Its single-lumen configuration provides one dedicated pathway for prescribed intravenous therapy while maintaining a relatively streamlined 4 Fr catheter profile.

A three-way Groshong valve at the distal end is designed to help control fluid movement through the catheter. The valve responds to pressure changes during infusion and aspiration while remaining closed under neutral pressure, helping reduce unintended blood reflux into the catheter lumen.

The catheter also features a rounded, radiopaque atraumatic distal tip designed to support vascular placement while minimizing unnecessary mechanical trauma when appropriately positioned.

The exact BD 7617405 configuration is a basic tray without a microintroducer. It has a listed gravity flow rate of approximately 540 mL per hour, a priming volume of approximately 0.45 mL, an 18-gauge equivalent lumen, and an internal diameter of approximately 0.033 inch.

BD 7617405 is supplied five PICC catheter trays per case for professional hospital, infusion, oncology, and vascular-access applications.

Key Benefits

  • 4 Fr single-lumen PICC provides dedicated central venous access for compatible prescribed therapies.
  • Groshong three-way valve is designed to help regulate fluid flow and reduce blood reflux.
  • Silicone catheter construction supports flexibility and extended vascular-access applications.
  • Radiopaque stripe supports visualization during appropriate catheter-placement assessment.
  • Rounded radiopaque atraumatic tip supports controlled vascular positioning.
  • Single-lumen configuration provides a streamlined option when one central infusion pathway is sufficient.
  • Approximately 540 mL per hour gravity flow capability supports compatible infusion applications.
  • Approximate 0.45 mL priming volume assists with fluid-volume planning.
  • 18-gauge equivalent lumen provides a defined internal flow pathway.
  • Approximately 0.033-inch internal diameter supports compatible infusion and aspiration procedures.
  • Proximal Luer connector supports connection with compatible vascular-access components.
  • Anti-kink design features help support catheter integrity near the connector assembly.
  • Groshong valve technology can support simplified catheter-maintenance protocols when used according to current manufacturer instructions.
  • Basic tray configuration supports facilities that maintain separate preferred PICC insertion supplies.
  • Five-per-case packaging supports professional vascular-access inventory management.

Compatibility and Applications

The BD 7617405 Groshong NXT ClearVue PICC is intended for appropriate central venous access applications performed by trained healthcare professionals.

Potential applications include compatible intravenous medication administration, antibiotic therapy, chemotherapy, hydration, parenteral nutrition, blood specimen collection, and other prescribed therapies requiring reliable central vascular access.

The 4 Fr single-lumen configuration may be appropriate when one infusion pathway meets the patient's treatment requirements. Clinicians should consider therapy type, anticipated duration, prescribed medications, infusion characteristics, vessel size, patient anatomy, and institutional vascular-access policies before selecting the catheter.

The Groshong valve is designed to remain closed at neutral pressure and respond appropriately during positive-pressure infusion or negative-pressure aspiration. This valve configuration is intended to help reduce blood reflux while supporting infusion and blood-withdrawal procedures according to current manufacturer instructions.

The basic tray configuration does not include the same procedural components as a full nursing tray or a basic tray specifically supplied with a microintroducer. Facilities should verify that all required insertion, guidewire, introducer, sterile preparation, securement, dressing, and connection components are available before beginning the procedure.

BD 7617405 should not be assumed to be suitable for power injection. Clinicians should verify the exact product labeling, implanted catheter specifications, and complete system compatibility before any pressure-injection procedure. When power injection is required, a catheter specifically labeled for the intended pressure and flow conditions should be selected.

Usage Guidelines

The BD 7617405 PICC Catheter Tray should be used only by healthcare professionals trained and authorized in PICC placement, central venous access, sterile insertion technique, catheter-tip positioning, maintenance, and complication management.

  • Confirm the clinical indication for PICC placement and the prescribed vascular-access plan.
  • Review patient history for relevant contraindications, vascular conditions, allergies, and procedural risks.
  • Assess the intended vein and insertion site using appropriate clinical techniques.
  • Verify that a 4 Fr single-lumen catheter meets the patient's therapy and vascular-access requirements.
  • Confirm the exact BD 7617405 product identity before opening the tray.
  • Inspect the package for damage, moisture, punctures, contamination, or compromised integrity.
  • Confirm that all additional supplies required for the planned insertion technique are available because this is a basic tray configuration.
  • Perform hand hygiene and establish an appropriate sterile field according to institutional protocol.
  • Prepare the insertion site using approved skin-antisepsis procedures.
  • Use ultrasound guidance and other placement technologies when required by institutional policy and clinical practice.
  • Insert and advance the catheter using the approved technique and current manufacturer instructions.
  • Avoid excessive force if resistance is encountered during catheter advancement.
  • Position the catheter tip according to current central venous access standards and institutional protocol.
  • Confirm catheter-tip location using an approved placement-confirmation method before initiating therapies that require confirmed central positioning.
  • Assemble and secure the proximal connector according to current manufacturer instructions.
  • Verify catheter patency before use.
  • Apply an appropriate stabilization device and sterile dressing.
  • Document external catheter length to assist with monitoring for migration.
  • Flush and maintain the catheter according to current Groshong catheter instructions and institutional policy.
  • Assess the insertion site and catheter function regularly throughout therapy.

Do not force flushing or infusion against unexplained resistance. If the catheter does not flush or aspirate as expected, assess for mechanical obstruction, malposition, thrombosis, catheter migration, or other potential causes according to institutional protocol.

Certifications and Safety Standards

The BD 7617405 Groshong NXT ClearVue PICC is a prescription vascular-access device intended for professional clinical use. PICC placement and maintenance should follow current manufacturer labeling, institutional policies, central-line infection-prevention standards, and applicable professional guidelines.

The catheter incorporates a radiopaque stripe and rounded radiopaque tip to support appropriate visualization and placement assessment.

The product is intended for single use. Devices intended for single use should not be reused or reprocessed unless specifically permitted by applicable manufacturer labeling and regulatory requirements.

The exact US product information indicates that the device is labeled as not made with natural rubber latex.

Healthcare organizations should maintain procedures addressing maximal sterile barrier precautions, skin antisepsis, catheter-tip confirmation, dressing management, connector disinfection, catheter securement, flushing, occlusion management, infection surveillance, and catheter removal.

Facilities should review current BD documentation for applicable FDA status, UDI information, sterilization details, shelf life, storage requirements, warnings, precautions, contraindications, and all other product-specific regulatory requirements before clinical use.

Comparison with Competitors

Compared with open-ended PICC designs, the Groshong catheter incorporates a three-way distal valve designed to control fluid movement and help reduce blood reflux under neutral conditions.

Compared with dual- or multi-lumen PICCs, the BD 7617405 single-lumen configuration provides one dedicated infusion pathway and a smaller overall catheter profile than many comparable multi-lumen configurations. Multi-lumen devices may be more appropriate when simultaneous incompatible therapies require separate pathways.

Compared with polyurethane PICCs, the Groshong NXT ClearVue catheter uses silicone construction. Catheter material selection should consider therapy requirements, clinician preference, institutional protocols, flow requirements, and patient-specific factors.

Compared with a full nursing tray, the BD 7617405 basic tray provides a more focused configuration for facilities that already stock preferred sterile procedural supplies separately.

Compared with Groshong basic trays supplied with a microintroducer, the exact BD 7617405 configuration is identified as a basic tray without a microintroducer. Facilities should ensure that the appropriate introducer and other required insertion components are available separately when needed.

Compared with power-injectable PICCs, BD 7617405 should not be selected on the assumption that it supports high-pressure contrast injection. A catheter specifically labeled for power injection should be selected when that capability is required.

Alternative PICC systems may differ in catheter material, French size, lumen count, valve technology, flow capability, pressure rating, insertion components, securement compatibility, and tray configuration. Product selection should reflect the patient's therapy plan and institutional vascular-access standards.

Typical User Profile and Application Scenarios

The BD 7617405 PICC Catheter Tray is intended for trained healthcare professionals responsible for central vascular-access placement and management. Typical users may include vascular-access nurses, interventional radiology teams, physicians, advanced practice clinicians, oncology professionals, infusion specialists, and other appropriately trained healthcare personnel.

Common use environments include hospitals, oncology centers, infusion centers, interventional radiology departments, vascular-access services, specialty treatment centers, and other clinical environments where peripherally inserted central catheters are routinely placed and managed.

The 4 Fr single-lumen configuration may be selected for patients requiring one central venous pathway for extended antibiotic therapy, chemotherapy, hydration, nutritional support, repeated medication administration, blood sampling, or other compatible treatments.

The Groshong valve design may be beneficial in clinical programs seeking a valved PICC platform with reduced blood-reflux characteristics and maintenance protocols based on current manufacturer recommendations.

Best Practices for Use and Maintenance

Best practices for BD 7617405 focus on appropriate patient selection, sterile insertion, accurate catheter-tip positioning, securement, infection prevention, routine assessment, flushing, and prompt management of complications.

  • Verify catalog number 7617405 before opening the package.
  • Confirm the 4 Fr single-lumen Groshong configuration and basic tray contents.
  • Ensure all required supplemental insertion supplies are available before starting the procedure.
  • Use maximal sterile barrier precautions during PICC insertion.
  • Use appropriate skin antisepsis and allow antiseptic solution to dry according to protocol.
  • Select a vein appropriate for the catheter size and prescribed therapy.
  • Minimize unnecessary catheter-to-vein ratio when selecting the access vessel.
  • Avoid excessive force during insertion or advancement.
  • Confirm final catheter-tip position using an approved technique.
  • Secure the catheter using an appropriate stabilization method.
  • Record and monitor external catheter length for evidence of migration.
  • Maintain a clean, dry, intact dressing and replace it according to institutional policy.
  • Disinfect access connectors before every connection or manipulation.
  • Flush the catheter according to current Groshong instructions and facility protocol.
  • For intermittent use, follow manufacturer guidance regarding saline flushing frequency and volume.
  • Do not flush against unexplained resistance.
  • Assess for occlusion, migration, infection, thrombosis, leakage, catheter damage, or other complications when function changes.
  • Do not use for power injection unless the exact applicable manufacturer labeling specifically authorizes the complete system for the intended procedure.
  • Remove the PICC when it is no longer clinically necessary or when removal is indicated by a complication.

Regulatory and Safety Information

The BD 7617405 Groshong NXT ClearVue PICC is a prescription medical device intended for placement and management by appropriately trained healthcare professionals.

The exact CIA Medical product configuration is a 4 Fr single-lumen Groshong NXT ClearVue PICC supplied in a basic tray without a microintroducer. It is listed with a gravity flow rate of approximately 540 mL per hour, a priming volume of approximately 0.45 mL, an 18-gauge equivalent lumen, and an internal diameter of approximately 0.033 inch.

The catheter is constructed from silicone rubber with a radiopaque stripe and incorporates a three-way Groshong valve, proximal Luer connector, anti-kink features, and a rounded radiopaque atraumatic distal tip.

Incorrect placement or inadequate catheter management may contribute to complications including catheter malposition, migration, occlusion, thrombosis, infection, phlebitis, bleeding, air embolism, catheter damage, extravasation, or other vascular-access complications.

Catheter-tip location should be confirmed according to institutional protocol before therapies requiring confirmed central venous placement are initiated.

Do not force infusion or flushing against resistance. Resistance may indicate occlusion, mechanical obstruction, malposition, catheter damage, or another condition requiring clinical evaluation.

This product should not be assumed to be power injectable. Verify the exact applicable product labeling before any pressure-injection procedure and use only devices specifically approved for the intended pressure and flow conditions.

BD 7617405 is supplied five units per case. Purchasing personnel should confirm current availability, tray configuration, product labeling, storage requirements, and ordering information before procurement.

How to Order

Select the BD 7617405 - PICC Catheter Tray, Basic, Groshong, Single, 4 FR and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.