(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD BCAT4511 - Standard Tray, 11G x 4" T-Handle Jamshidi Needle, 15G x 3" T-Handle Illinois Needle, (Rx), 10/cs (Temp Sensitive; Non-Returnable) (Continental US Only, Excluding IN and ND)

BD  # BCAT4511 - Standard Tray, 11G x 4
Part Number BD BCAT4511
SKU Number CIA8042180
Sell Unit CASE
Ships Within Special Order
List Price $1,659.81
Enter a valid quantity
Product Description

BD BCAT4511 - Standard Tray, 11G x 4" T-Handle Jamshidi Needle, 15G x 3" T-Handle Illinois Needle, (Rx), 10/cs (Temp Sensitive; Non-Returnable) (Continental US Only, Excluding IN and ND)

The BD BCAT4511SP Safe-T PLUS Tray is a sterile procedural tray designed to support bone marrow aspiration and biopsy procedures in professional healthcare settings. This tray includes an 11G x 4 inch T-Handle Jamshidi needle and a 15G T-Handle Illinois needle, providing clinicians with essential instruments for obtaining bone marrow core biopsy and aspiration specimens.

The Safe-T PLUS tray configuration is designed to streamline procedural preparation by organizing critical components into a convenient sterile package. The T-handle needle design supports controlled advancement, enhanced grip, and precise handling during bone marrow sampling procedures.

This prescription-only tray is intended for use by qualified healthcare professionals performing diagnostic and monitoring procedures related to hematologic and oncologic conditions.

Key Benefits

The BD BCAT4511SP provides a comprehensive procedural solution that helps improve workflow efficiency by reducing setup time and consolidating essential biopsy components into a single sterile tray.

The included 11G x 4 inch T-Handle Jamshidi needle supports the collection of high-quality bone marrow core biopsy specimens, while the 15G T-Handle Illinois needle is commonly used for bone marrow aspiration procedures.

The ergonomic T-handle design helps support clinician control during needle placement and specimen collection.

The sterile, single-use tray helps support infection prevention initiatives and reduces the risk of cross-contamination between patients.

Compatibility and Applications

The BD BCAT4511SP is intended for use in bone marrow biopsy and aspiration procedures performed by trained healthcare professionals. The tray may be used alongside compatible syringes, specimen collection containers, pathology supplies, local anesthetics, and other procedural accessories selected according to institutional protocols.

Typical applications include bone marrow biopsy, bone marrow aspiration, hematology diagnostics, oncology evaluations, disease staging, treatment monitoring, pathology specimen collection, and laboratory analysis.

This tray is commonly used in hospitals, cancer treatment centers, hematology clinics, oncology departments, pathology laboratories, and outpatient procedural facilities.

Usage Guidelines

The BD BCAT4511SP should be used only by clinicians trained in bone marrow aspiration and biopsy techniques. Prior to use, verify package integrity, sterility, expiration date, patient identity, and procedural requirements.

Prepare the procedural site according to institutional aseptic protocols and applicable clinical guidelines. Use the Jamshidi and Illinois needles in accordance with manufacturer instructions, professional standards of care, and clinical judgment.

After specimen collection, ensure proper labeling and handling of samples according to laboratory requirements. Dispose of all used sharps and tray components in accordance with facility policies and applicable regulations.

Certifications and Safety Standards

The BD BCAT4511SP Safe-T PLUS Tray is manufactured under established medical device quality management systems and is designed to support safe procedural practices in healthcare environments.

The sterile, single-use configuration aligns with infection prevention standards and helps support compliance with institutional safety protocols. Healthcare facilities should review current product labeling and regulatory documentation before use.

Comparison with Competitor Products

Compared with individually sourced procedural components, the BD BCAT4511SP provides a convenient all-in-one tray configuration that can help improve procedural consistency and reduce setup complexity.

Compared with basic biopsy trays, the Safe-T PLUS configuration includes both T-Handle Jamshidi and T-Handle Illinois needles, supporting both biopsy and aspiration procedures within a single package.

The recognized Jamshidi and Illinois needle designs provide clinicians with trusted instruments commonly used in bone marrow sampling procedures.

Typical User Profile and Application Scenarios

The BD BCAT4511SP is commonly used by hematologists, oncologists, pathologists, interventional physicians, physician assistants, nurse practitioners, and other healthcare professionals trained in bone marrow sampling procedures.

Typical applications include evaluation of hematologic disorders, cancer diagnosis and staging, bone marrow monitoring, treatment response assessment, pathology specimen collection, and diagnostic laboratory testing.

Best Practices for Use and Maintenance

Store the BD BCAT4511SP in a clean, dry environment according to manufacturer recommendations. Maintain the tray in its original sterile packaging until immediately before use.

Use strict aseptic technique throughout the procedure. Verify specimen collection requirements before beginning the procedure and ensure all samples are properly identified and transported according to laboratory protocols.

The tray and all included components are intended for single use only and should not be reused, reprocessed, or resterilized.

Regulatory and Safety Information

The BD BCAT4511SP Safe-T PLUS Tray is intended for professional healthcare use only and is available by prescription. Bone marrow aspiration and biopsy procedures should be performed only by qualified healthcare professionals following manufacturer instructions, institutional policies, and applicable healthcare regulations.

Healthcare personnel should follow standard precautions, sharps safety procedures, infection prevention protocols, and specimen handling guidelines throughout the procedure.

All used sharps and biohazardous materials should be disposed of according to facility policies and biomedical waste regulations.

How to Order

Select the BD BCAT4511SP Safe-T PLUS Tray with 11G x 4 Inch T-Handle Jamshidi Needle and 15G T-Handle Illinois Needle and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, pricing information, product availability, or further assistance, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page.

Related Products