(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

BD CH114 - Vascular Maxi Loop, Blue, 0.10" x 14.75" x 0.04", Radiopaque Silicone, Sterile, 10/BX (Temp Sensitive; Non-Returnable) (Continental US Only)

BD  # CH114 - Vascular Maxi Loop, Blue, 0.10
Part Number BD CH114
SKU Number CIA8042443
Sell Unit BOX
Ships Within Special Order
List Price $102.92
Enter a valid quantity
Product Description

BD CH114 - Vascular Maxi Loop, Blue, 0.10" x 14.75" x 0.04", Radiopaque Silicone, Sterile, 10/BX (Temp Sensitive; Non-Returnable) (Continental US Only)

The BD CH114 Vascular Maxi Loop is a sterile, single-use surgical loop designed to support the identification, retraction, and temporary control of anatomical structures during vascular and other surgical procedures. The blue Maxi loop measures 0.10 inch wide by 14.75 inches long by 0.04 inch deep, or approximately 2.5 mm x 375 mm x 1 mm, providing a flexible profile for controlled surgical handling.

Made from medical-grade radiopaque silicone, the BD CH114 is designed for use with arteries, veins, tendons, nerves, and other appropriate anatomical structures. The flexible silicone construction allows the loop to conform around structures while the blue color provides clear visual differentiation within the surgical field.

The radiopaque construction provides an additional identification feature during surgical procedures, while the sterile, single-use design supports established infection-control and operating room protocols. The product is not made with natural rubber latex and is packaged two loops per pack with 10 packs per box.

Key Benefits

  • Maxi-size vascular loop supports identification, retraction, and temporary control of appropriate anatomical structures.
  • Blue color provides clear visual contrast and supports differentiation within the operative field.
  • Medical-grade silicone construction provides flexibility for controlled surgical placement.
  • Radiopaque material supports identification when radiographic detection is clinically required.
  • Suitable for use with arteries, veins, tendons, nerves, and other appropriate structures.
  • Sterile presentation supports established aseptic surgical workflows.
  • Single-use design eliminates the need for reprocessing between procedures.
  • Not made with natural rubber latex for facilities managing latex-related product requirements.
  • Long 14.75-inch configuration provides ample length for handling and positioning during surgical procedures.

Compatibility and Applications

The BD CH114 Vascular Maxi Loop is designed for use within established vascular, general, orthopedic, and other surgical workflows where temporary identification, isolation, retraction, or control of anatomical structures is required.

Typical applications may include identifying arteries and veins, retracting vessels or other structures from the operative field, temporarily controlling vascular structures, and distinguishing tendons or nerves during appropriate surgical procedures.

The Maxi configuration is appropriate when a larger vascular loop profile is preferred compared with smaller Mini loop options. Selection should be based on the anatomical structure, surgical technique, clinician preference, and current manufacturer instructions.

The product is suitable for hospital operating rooms, ambulatory surgery centers, vascular surgery departments, specialty surgical facilities, and other controlled procedural environments. It may be used with compatible surgical instruments and vessel-management techniques when clinically appropriate.

Usage Guidelines

Before use, confirm the BD CH114 catalog number, blue color, Maxi dimensions, sterile package integrity, and suitability for the intended surgical procedure. Do not use the product if the sterile packaging is opened, damaged, wet, punctured, or otherwise compromised.

  • Use appropriate aseptic technique when opening the package and introducing the vascular loop into the sterile field.
  • Select the loop only when the Maxi size is appropriate for the anatomical structure and intended surgical technique.
  • Position the loop carefully around the intended vessel, tendon, nerve, or other anatomical structure.
  • Apply only the amount of tension necessary for the intended identification, retraction, or temporary control.
  • Avoid excessive force that could damage or compress delicate tissue.
  • Maintain clear visual identification of the blue loop throughout the procedure.
  • Account for all surgical loops introduced into the operative field according to institutional procedures.
  • Dispose of the product after use according to applicable infection-control and medical waste requirements.

Healthcare professionals should consult current manufacturer labeling and institutional surgical protocols for complete product-specific handling, warnings, contraindications, and disposal information.

Certifications and Safety Standards

The BD CH114 Vascular Maxi Loop is intended for professional surgical use and should be handled in accordance with applicable medical device regulations, infection-prevention procedures, surgical safety protocols, and current manufacturer instructions.

The product is supplied sterile and is intended for single use. Maintaining package integrity and appropriate aseptic technique is essential for preserving the sterile condition before use.

The medical-grade radiopaque silicone construction provides an additional identification feature when radiographic detection is clinically required. Radiopacity should complement established surgical item accountability procedures rather than replace manual counts, visual inspection, or other institutional safety practices.

The product is not made with natural rubber latex. Healthcare facilities and procurement teams should verify current manufacturer documentation for applicable regulatory status, UDI information, sterilization details, expiration dating, and other product-specific requirements.

Comparison with Competitors

Compared with Mini vascular loops, the BD CH114 Maxi Loop provides a larger 0.10-inch width and 0.04-inch depth. This larger profile may be preferred when greater visibility or a more substantial loop configuration is required for the surgical procedure.

Compared with non-radiopaque vessel loops, the radiopaque silicone construction of the BD CH114 provides an additional detection feature that can support surgical safety procedures when radiographic identification is required.

Compared with reusable vessel-control accessories, the sterile single-use design eliminates the need for cleaning and reprocessing between procedures. This can simplify workflow and support standardized single-use surgical practices.

Competing vascular loops may vary in dimensions, color, material, radiopacity, sterility, and packaging configuration. The BD CH114 combines a blue Maxi profile, medical-grade radiopaque silicone, sterile single-use presentation, and a 14.75-inch length for professional surgical use.

Typical User Profile and Application Scenarios

The BD CH114 Vascular Maxi Loop is intended for trained healthcare professionals involved in vascular and other surgical procedures. Typical users may include vascular surgeons, general surgeons, orthopedic surgeons, physicians, operating room nurses, surgical technologists, and other qualified clinical personnel.

Typical application scenarios include vascular procedures requiring temporary vessel control, identification of arteries or veins, retraction of anatomical structures, and visual differentiation of tendons or nerves during surgery.

The blue color may be incorporated into a surgeon's or facility's color-based identification approach when multiple structures or loops are used during a procedure. The specific meaning assigned to each color should remain consistent within the surgical team and procedure.

The product is particularly relevant for hospitals, operating rooms, ambulatory surgery centers, vascular surgery facilities, and other healthcare environments that require sterile single-use surgical accessories.

Best Practices for Use and Maintenance

The BD CH114 is a sterile, single-use surgical product and should be stored, handled, used, and disposed of according to current manufacturer labeling and healthcare facility procedures. It is not intended to be maintained or reprocessed as reusable equipment.

  • Store unopened products according to manufacturer-recommended environmental conditions.
  • Protect sterile packaging from moisture, contamination, excessive heat, crushing, and physical damage.
  • Rotate inventory according to expiration dates when applicable.
  • Verify the correct catalog number, blue color, and Maxi size before opening the package.
  • Inspect the sterile barrier and loop condition before use.
  • Avoid cutting, modifying, excessively stretching, or otherwise altering the loop.
  • Use only the amount of tension required for the intended surgical purpose.
  • Maintain accountability for all loops introduced into the operative field.
  • Do not reuse or reprocess the single-use product.
  • Dispose of used loops according to applicable infection-control and regulated medical waste procedures.

Regulatory and Safety Information

The BD CH114 Vascular Maxi Loop should be used only by appropriately trained healthcare professionals and only for applications consistent with current manufacturer labeling, professional clinical judgment, and institutional policy.

Before use, verify the product identity, dimensions, blue color, sterile package integrity, expiration information when applicable, and suitability for the intended procedure. A damaged, contaminated, or compromised product should not be used.

Excessive tension or inappropriate application may damage delicate anatomical structures. The loop should be positioned and manipulated using accepted surgical technique and only under the direction of a qualified healthcare professional.

The product is made from medical-grade radiopaque silicone, supplied sterile, intended for single use, and not made with natural rubber latex. All vascular loops introduced into the operative field should be managed according to applicable surgical item accountability procedures.

Specific FDA status, UDI information, sterilization method, expiration requirements, and other regulatory characteristics should be confirmed from current manufacturer documentation when required for purchasing, facility approval, or clinical use.

How to Order

Select the BD CH114 - Vascular Maxi Loop, Blue, Single Use, Sterile and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products