Carefusion 019-400500 - Disposable Ground Plate Electrode 40 x 50 mm Ag/AgCl with 1.0 m Lead Wire and Touchproof Connector, Latex-Free, 24/BX

Carefusion # 019-400500 - Disposable Ground Plate Electrode  40 x 50 mm Ag/AgCl with 1.0 m Lead Wire and Touchproof Connector, Latex-Free, 24/BX
Part Number Carefusion 019-400500
SKU Number CIA1015994
Sell Unit BOX
Ships Within Special Order
List Price $99.56
Enter a valid quantity
Product Description

Carefusion 019-400500 - Disposable Ground Plate Electrode 40 x 50 mm Ag/AgCl with 1.0 m Lead Wire and Touchproof Connector, Latex-Free, 24/BX

The Carefusion 019-400500 Disposable Ground Plate Electrode is a single-use, pre-gelled electrode designed to provide a stable ground reference during neurodiagnostic procedures such as electromyography (EMG), nerve conduction studies (NCS), and evoked potential recordings. Measuring 40 x 50 mm, this self-adhesive electrode features a silver/silver chloride (Ag/AgCl) sensor for consistent signal quality and a 1.0-meter (39-inch) green lead wire terminating in a 1.5 mm touchproof female connector, ensuring universal compatibility with most diagnostic systems.

Its disposable design eliminates cleaning and reprocessing, while latex-free materials make it safe for use with sensitive patient populations.

Manufacturer019-400500
ApplicationEMG Adhesive Ground Plate Electrode with Leadwire
Dimensions40 X 50 mm Contact Area X 36 Inch Lead Length
MaterialSilver / Silver Chloride
SterilityNonSterile
Tip TypeTab Tip
UsageDisposable

Key Benefits

  • Reliable Signal Quality: The Ag/AgCl sensor provides low impedance and stable signals for accurate diagnostic output.

  • Pre-Gelled Adhesive Backing: Ensures quick, secure placement and strong skin contact without additional preparation.

  • 1.0 m Lead Wire: Offers extended reach and flexibility in setup across different patient positions.

  • Touchproof Connector: The 1.5 mm female touchproof end is universally compatible with standard EMG and neurodiagnostic equipment.

  • Latex-Free & Hypoallergenic: Safe for use with patients who have latex sensitivities or skin allergies.

  • Disposable for Infection Control: Single-use design supports clinical hygiene protocols and eliminates the need for disinfection or sterilization.

Product Specifications

  • Electrode Size: 40 mm x 50 mm

  • Sensor Type: Silver/Silver Chloride (Ag/AgCl)

  • Lead Wire Length: 1.0 meter (39 inches)

  • Connector: 1.5 mm female touchproof

  • Sterility: Non-sterile

  • Latex-Free: Yes

  • Packaging: 24 individually packaged electrodes per box

  • Shelf Life: Up to 24 months from date of manufacture

Compatibility and Applications
This electrode is compatible with most leading EMG, EEG, and intraoperative monitoring systems. Ideal for use in:

  • Neurology departments for standard EMG and NCS procedures

  • Surgical suites during intraoperative neuromonitoring (IONM)

  • Rehabilitation clinics for biofeedback and electrical stimulation grounding

  • Outpatient diagnostic centers conducting evoked potential testing and reflex studies

Usage Guidelines

  1. Inspect Packaging: Verify that the product packaging is intact and not expired.

  2. Skin Prep: Clean and dry the skin at the application site.

  3. Apply Electrode: Remove the backing and firmly press the electrode onto the skin.

  4. Connect Lead: Plug the 1.5 mm connector into the diagnostic systems ground port.

  5. Remove and Dispose: After the procedure, carefully remove the electrode and discard it in appropriate medical waste containers.

Certifications and Compliance

  • FDA Registered for use in medical diagnostics

  • ISO 13485 Certified for quality and safety in medical device manufacturing

  • CE Marked to meet European Union regulatory standards

  • Latex-Free Construction for maximum patient safety

Comparison with Competitor Products
The Carefusion 019-400500 outperforms generic ground electrodes with:

  • Superior signal stability from high-quality Ag/AgCl material

  • Universally compatible touchproof connector

  • Pre-gelled convenience for faster application and strong adhesion

  • Disposable, hygienic design for reduced cross-contamination risks

Most competing electrodes require manual gel application or offer shorter lead wires that limit placement flexibility.

Typical Users and Clinical Scenarios

  • Neurologists and EMG technicians conducting electrodiagnostic evaluations

  • Intraoperative monitoring teams requiring secure and stable grounding

  • Rehab therapists integrating biofeedback into treatment protocols

Ideal for use in hospitals, surgical centers, and outpatient diagnostic environments.

Best Practices for Use and Maintenance

  • Storage: Keep in a cool, dry place; avoid excessive heat or humidity.

  • Pre-Use Inspection: Check for intact gel and insulation before connecting.

  • Application: Ensure strong skin contact for optimal performance.

  • Disposal: Follow all medical waste handling protocols for single-use items.

Regulatory and Safety Information
For use by trained medical professionals only. Ensure proper application technique and connection to compatible systems to ensure accurate test results and patient safety.

How to Order
To purchase the Carefusion 019-400500 Disposable Ground Plate Electrode:

  • Add the product to your cart and complete your purchase through the CIA Medical platform.

  • For bulk orders or inquiries, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page.