(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Carefusion 2426-0500 - IV Admin Set 20Drp 127" Chkvlv 3 Vlv M-LL Pump Module,20/CA

Carefusion # 2426-0500 - IV Admin Set 20Drp 127
Part Number Carefusion 2426-0500
SKU Number CIA1129291
Sell Unit CASE
Ships Within 24 Hours
List Price Call for Pricing
Product Description

Carefusion 2426-0500 - IV Admin Set 20Drp 127" Chkvlv 3 Vlv M-LL Pump Module,20/CA

The Carefusion 2426-0500 IV Administration Set is an essential medical device designed to deliver fluids and medications intravenously. This product is characterized by its 20-drop per milliliter flow rate, which ensures controlled and precise fluid administration. The set is 127 inches in length, providing adequate reach for various medical setups, including both short-term and extended infusions. The integrated check valve and three-valve configuration ensure optimal control over the fluid delivery, preventing backflow and ensuring a smooth and accurate infusion process. This product is commonly used in hospitals, clinics, and outpatient care centers where precise fluid administration is crucial.

Manufacturer2426-0500
Administration MethodPump
ApplicationIV Pump Set
Back Check ValveBack Check Valve
Connection TypeMale Luer Lock Connector
DEHP IndicatorDEHP Tubing
Drip Rate20 Drops / mL Drip Rate
FilterWithout Filter
Flow Control TypeRoller Clamp / Slide Clamp
For Use WithFor use with Alaris LVP Infusion Pumps
Injection Port Type GroupingNeedle-Free Port
Number of Ports3 Ports
Priming Volume26 mL Priming Volume
Spike TypeUniversal Spike
SterilitySterile Fluid Path
Tubing Length126 Inch Tubing
TypeSolution

Key Features

  • 20-Drop Flow Rate: Ensures controlled and accurate fluid administration, allowing healthcare professionals to administer specific volumes of fluids or medications.
  • 127-Inch Length: Provides flexibility in use, ideal for a wide range of patient positions and infusion needs.
  • Three-Valve System: Features a check valve to prevent backflow and two additional valves to enhance flow control, improving the precision of fluid delivery.
  • Sterile, Single-Use Design: Reduces the risk of cross-contamination, promoting patient safety by ensuring each set is used only once.

Key Benefits
The Carefusion 2426-0500 IV Admin Set is designed with safety and efficiency in mind. The sterile, single-use design minimizes the risk of infection by preventing contamination from reused sets. The 20-drop flow rate is ideal for precise fluid and medication administration, reducing the likelihood of under or over-infusion, which can lead to adverse patient outcomes. The check valve system ensures that fluids flow in the right direction, further enhancing patient safety. The three-valve configuration allows for greater flexibility and control in diverse medical scenarios, improving the overall efficiency of medical procedures.

Compatibility and Applications
This IV administration set is compatible with most infusion pumps and standard IV catheter setups. Its design ensures seamless integration into a variety of medical applications, including emergency care, routine hospital infusions, surgery, and home healthcare settings. The extended tubing length (127 inches) makes it particularly useful for patients in various positions or situations where shorter tubing might be limiting. The sets ability to support various medications and fluids, such as saline, antibiotics, or chemotherapy drugs, makes it versatile for use in different departments like ICU, oncology, and surgical units.

Usage Guidelines
Proper usage of the Carefusion 2426-0500 IV Admin Set is critical to ensure patient safety and effective treatment.

  • Preparation: Before connecting the IV set, check the packaging for any signs of damage or contamination.
  • Sterile Setup: Maintain sterile technique during setup and ensure the IV set is properly connected to the patients catheter.
  • Monitoring: While infusing fluids, closely monitor the patients response and the IV site for any complications, such as swelling or infiltration.
  • Disposal: Once the infusion is complete, safely dispose of the IV administration set in accordance with hospital protocols to prevent infection.

Certifications, Safety Standards, and Regulatory Approvals
The Carefusion 2426-0500 IV Admin Set meets several important safety and regulatory standards. It is FDA-approved and has received the CE Mark, ensuring it complies with stringent medical device safety regulations in both the United States and Europe. Additionally, this product meets ISO 13485 standards for quality management systems in the design and manufacture of medical devices, reinforcing its reliability and safety for use in patient care environments.

Comparison with Competitor Products
When comparing the Carefusion 2426-0500 to other IV administration sets on the market, it stands out for its advanced valve system and longer tubing length. Many competitor products may not offer a three-valve configuration, potentially leading to less control over fluid flow. Furthermore, the longer tubing (127 inches) gives healthcare professionals more flexibility in setting up the IV administration, especially in emergency situations or when a patient requires a specific positioning. Additionally, the Carefusion sets 20-drop flow rate is a standard used by most hospitals, making it a preferred choice for medical professionals who need reliable, standardized fluid delivery.

Typical User Profile and Application Scenarios
The typical users of the Carefusion 2426-0500 IV Admin Set are healthcare professionals, including nurses, medical technicians, and caregivers who are involved in the delivery of intravenous fluids and medications. These sets are commonly used in various settings, including emergency rooms, intensive care units (ICU), oncology wards, surgical recovery areas, and outpatient clinics. Additionally, this product is beneficial for home healthcare providers who need reliable and efficient tools for managing long-term IV therapy, ensuring patients receive the appropriate fluids and medications at home.

Best Practices for Use and Maintenance
To ensure optimal performance, follow these best practices:

  • Inspect the Set: Before use, verify that all parts of the IV set are intact, and check that the valves are functioning properly.
  • Proper Placement: Ensure the IV set is securely attached to the catheter and that there is no kinking or bending of the tubing during fluid administration.
  • Sterile Disposal: Dispose of the set immediately after use, following hospital or healthcare facility protocols to maintain hygiene and prevent contamination.
  • Prevent Backflow: Ensure that the check valve is functioning properly to prevent any backflow of fluids that could compromise the patients safety.

Regulatory and Safety Information
The Carefusion 2426-0500 IV Admin Set is certified to meet the highest safety standards. Its FDA approval and CE Mark provide confidence that the product adheres to rigorous health, safety, and environmental protection standards. Additionally, the product meets ISO 13485 quality management standards, which govern the design and manufacturing process for medical devices, ensuring it is built to deliver reliable and safe performance in healthcare environments.

How to Order
To order the Carefusion 2426-0500 IV Admin Set, visit the CIA Medical website. Simply search for the product by name and add it to your cart. Afterward, proceed to checkout and select your preferred payment and shipping methods. For bulk orders, special pricing, or more information, contact CIA Medical customer service at (312) 275-5850 or use the contact form on the website. Our customer service team will be happy to assist you with any inquiries or custom orders.