(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Carefusion 28293E - Infusion Set Alaris 20 Drop 18" 50/CS

Carefusion # 28293E - Infusion Set Alaris 20 Drop 18
Part Number Carefusion 28293E
SKU Number CIA7003418
Sell Unit CASE
Ships Within 24 Hours
List Price Call for Pricing
Product Description

Carefusion 28293E - Infusion Set Alaris 20 Drop 18" 50/CS

The Carefusion 28293E Alaris Infusion Set is designed for precise and efficient fluid delivery in clinical settings. Featuring a 20-drop per milliliter drip rate and 18 inches of tubing, this set is tailored for use with Alaris MedSystem III infusion pumps. It includes essential components such as a roller clamp for flow rate control, a check valve to prevent backflow, and two SmartSite needle-free valves to enhance safety and reduce the risk of contamination. The set is latex-free and comes in a case of 50, ensuring a reliable supply for healthcare facilities.

Key Benefits:
This infusion set offers several advantages:

  • Precision Flow Control: The 20-drop per milliliter drip rate ensures accurate fluid administration, crucial for patient safety.

  • Enhanced Safety Features: The inclusion of SmartSite needle-free valves minimizes the risk of needlestick injuries and cross-contamination.

  • Convenient and Efficient: The 18-inch tubing length provides flexibility in patient positioning, while the roller clamp allows for easy flow rate adjustments.

  • Reliable Performance: Designed for use with Alaris MedSystem III pumps, ensuring compatibility and optimal performance.

Drip Chamber

Pump Cassette for MSII

Rollar

Compatibility and Applications:
The Carefusion 28293E Infusion Set is compatible with Alaris MedSystem III infusion pumps, making it suitable for various medical environments, including hospitals and clinics. It is ideal for administering medications, fluids, and blood products to patients requiring precise and controlled infusion therapy.

Usage Guidelines:
To ensure optimal performance:

  • Inspect the set for any damage before use.

  • Connect the set securely to the infusion pump and patient access port.

  • Adjust the roller clamp to achieve the desired flow rate.

  • After use, dispose of the set according to your facility's safety protocols.

Preparing the Administration Set

Prime the IVAC 28 or 25 Series administration set in accordance with Administration Set Directions for Use. It is important to prime the set properly to eliminate air bubbles. Ensure the cassette slide clamp is pushed in completely so tubing is not occluded. Invert the cassette so tubing is up. Slowly open the regulating clamp and establish fluid flow to fully prime the set. Gently tap the cassette and 'Y' sites as necessary to remove all air. Gently massage the pressure dome to ensure no air bubbles are trapped.

Product Specifications

Certifications, Safety Standards, and Regulatory Approvals:
The Carefusion 28293E Infusion Set complies with relevant medical device regulations and standards, ensuring its safety and effectiveness in clinical applications.

Comparison with Competitor Products:
Compared to other infusion sets, the Carefusion 28293E offers:

  • Enhanced Safety: The SmartSite needle-free valves provide an added layer of protection against needlestick injuries.

  • Optimized Design: The 20-drop per milliliter drip rate and 18-inch tubing length are tailored for precise and flexible fluid administration.

  • Compatibility: Specifically designed for use with Alaris MedSystem III pumps, ensuring seamless integration and performance.

Typical User Profile and Application Scenarios:
This infusion set is commonly used by healthcare professionals, including nurses and clinicians, in settings where precise and controlled fluid administration is required. Typical scenarios include:

  • Medication Administration: Delivering intravenous medications to patients.

  • Fluid Therapy: Managing patients' fluid balance through intravenous fluids.

  • Blood Product Infusion: Administering blood and blood products under controlled conditions.

Best Practices for Use and Maintenance:
To maintain the integrity and safety of the infusion set:

  • Always handle the set with clean hands or gloves.

  • Ensure all connections are secure before starting the infusion.

  • Regularly monitor the infusion site for signs of complications.

  • Follow your facility's protocols for disposal and infection control.

Regulatory and Safety Information:
The Carefusion 28293E Infusion Set meets applicable safety standards and regulatory requirements, providing assurance of its quality and reliability in clinical use.

How to Order:
To order the Carefusion 28293E Infusion Set:

  1. Visit the product page on CIA Medical.

  2. Add the desired quantity to your cart.

  3. Proceed to checkout and complete your purchase.

For bulk orders or inquiries, contact CIA Medical customer service at (312) 275-5850 or use the contact form on their website.