Carefusion 7183-HS7 - Universal Breathing Circuit Single-Use, High-Efficiency Ventilator Circuit for Adult Respiratory Care, 20/CS

The Carefusion 7183-HS7 Universal Breathing Circuit is a high-performance, single-use respiratory circuit engineered for compatibility with a wide range of ventilators and anesthesia machines. Designed for adult patients, this universal circuit supports both pressure- and volume-controlled ventilation, delivering consistent airflow and optimal humidification in critical care, anesthesia, and respiratory therapy settings.

Constructed with premium-grade, latex-free materials, the circuit includes preassembled components for efficient setup and safe operation. Its universal design reduces the need to stock multiple circuit types, streamlining inventory while maintaining flexibility in patient care environments.

Key Benefits:

  • Universal Compatibility: Designed to fit most adult ventilators and anesthesia machines, eliminating the need for circuit-specific inventory.

  • Single-Use for Infection Control: Disposable construction reduces the risk of cross-contamination and supports infection prevention protocols.

  • Preassembled and Ready to Use: Speeds up setup time and reduces clinician workload during emergencies or high-turnover situations.

  • Flexible and Kink-Resistant Tubing: Ensures reliable airflow with minimal resistance or interruption.

  • Latex-Free & DEHP-Free Materials: Safe for patients with material sensitivities or respiratory compromise.

These features support efficient workflow, enhance safety, and improve patient comfort during respiratory interventions.

Compatibility and Applications:
The 7183-HS7 circuit is compatible with most adult mechanical ventilators and anesthesia machines, including:

  • ICU ventilators (e.g., Carefusion, Drger, GE, Puritan Bennett)

  • Portable transport ventilators

  • Anesthesia delivery systems

  • Continuous or intermittent positive pressure ventilation setups (IPPV/IMV/CMV)

Applications include:

  • Invasive and non-invasive ventilation

  • Surgical procedures requiring general anesthesia

  • Emergency airway management

  • Long-term ventilator support in ICUs or step-down units

Usage Guidelines:

  • Unpack and visually inspect the circuit before use.

  • Connect proximal ends to the ventilators inspiratory and expiratory ports.

  • Attach the patient interface (e.g., mask, ET tube) and secure all connections.

  • Ensure the circuit is properly supported to avoid drag on the patient airway.

  • Dispose of the entire circuit after a single patient use, following facility protocols.

Do not attempt to sterilize or reuse, as this product is intended for single-use only.

Certifications, Safety Standards, and Regulatory Approvals:
The Carefusion 7183-HS7 breathing circuit is:

  • FDA-registered as a Class II medical device

  • CE Marked under EU MDR for global compliance

  • Manufactured under ISO 13485 quality management systems

  • Latex-free and DEHP-free to support patient safety

  • Compliant with ISO 5367 standards for breathing system components

These certifications ensure high standards of product safety, traceability, and clinical performance.

Comparison with Competitor Products:
Compared to other universal circuits from brands like Hudson RCI, Medline, or Teleflex, the Carefusion 7183-HS7 stands out for its preassembled convenience, broad ventilator compatibility, and reliable construction. While some competitor circuits require additional components or adapters, this all-in-one system reduces complexity and potential failure points.

Carefusions trusted respiratory engineering offers consistent performance even under demanding conditions, making it a preferred choice among respiratory and critical care teams.

Typical User Profile and Application Scenarios:
Used by:

  • Respiratory therapists

  • Anesthesiologists

  • ICU and operating room nurses

  • Emergency and trauma care teams

  • Transport team clinicians

Typical scenarios:

  • Ventilation in critical care units

  • General anesthesia procedures

  • Emergency resuscitation during transport

  • Short- and long-term mechanical ventilation in hospital settings

Best Practices for Use and Maintenance:

  • Always inspect for damage, contamination, or occlusions before use.

  • Use in conjunction with appropriate humidification systems to prevent airway dryness.

  • Secure circuit tubing to minimize strain on airway devices.

  • Do not modify or extend the circuit, as it may compromise performance.

  • Dispose of after each use to maintain infection control compliance.

Regulatory and Safety Information:
The Carefusion 7183-HS7 is a single-use medical device designed to meet U.S. and international safety regulations. It contains no natural rubber latex and is manufactured using biocompatible materials tested under ISO 10993. The product is clearly marked for single patient use and includes batch and lot identifiers for traceability.

How to Order:
To order the Carefusion 7183-HS7 Universal Breathing Circuit, add the item to your cart and complete your purchase through CIA Medicals secure checkout.

For bulk orders, institutional quotes, or product selection assistance, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page. Our knowledgeable team is ready to support your facilitys respiratory care needs with trusted, compliant solutions.

Related Products