(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Carefusion CHI1815 - Chiba Fine Needle Aspiration Needle 18G x 15cm, Single-Use, 10/CS

Carefusion # CHI1815 - Chiba Fine Needle Aspiration Needle  18G x 15cm, Single-Use, 10/CS
Part Number Carefusion CHI1815
SKU Number CIA2211894
Sell Unit CASE
Ships Within Call for Availability
List Price $187.62
Product Description

Carefusion CHI1815 - Chiba Fine Needle Aspiration Needle 18G x 15cm, Single-Use, 10/CS

The CareFusion CHI1815 Chiba Fine Needle Aspiration (FNA) Needle is a precision medical tool designed for the collection of tissue samples for diagnostic and therapeutic procedures. With an 18G gauge and a 15cm length, this needle is suitable for performing fine needle aspirations of soft tissue masses, including organs such as the liver, lungs, kidneys, and lymph nodes. It features a Chiba-style tip, which is specifically designed to facilitate efficient tissue sampling with minimal damage to surrounding structures.

The CareFusion CHI1815 is ideal for use in ultrasound-guided procedures, where accuracy is critical for obtaining quality tissue samples. Each needle is individually sterilized and packaged to maintain aseptic conditions until use. It is a single-use device to ensure hygiene and prevent the risk of infection or cross-contamination between patients.

Key Features:

  • 18G Gauge: The 18G size strikes an ideal balance between strength and precision for adult tissue sampling, providing sufficient rigidity for aspiration without causing unnecessary trauma to surrounding tissue.

  • 15cm Length: This length is suitable for reaching soft tissue masses in deeper anatomical locations, providing an adequate reach for various biopsy sites.

  • Chiba-Style Tip: The sharp, tapered Chiba-style needle tip is designed to make clean, precise incisions, helping to minimize tissue damage and improve the quality of the samples collected.

  • Single-Use Design: The single-use nature of the needle ensures that each procedure is conducted with a sterile, new device, reducing the risk of infection and cross-contamination.

  • Stainless Steel Construction: The needle is made from high-quality stainless steel, ensuring durability and sharpness for accurate tissue sampling.

  • Individually Sterilized and Packaged: Each needle is individually sealed in sterile packaging, ensuring that it is free from contaminants and safe to use in sensitive medical environments.

  • 10 Units per Box: Each box contains 10 individually packaged needles, making it a cost-effective solution for healthcare facilities requiring a consistent supply of FNA needles.

Applications:

The CareFusion CHI1815 Chiba FNA Needle is used in various medical and diagnostic procedures, including:

  • Fine Needle Aspiration (FNA): The needle is ideal for aspirating small tissue samples for cytological analysis. This can be used for diagnosing a range of conditions, such as cancer, infections, or benign growths.

  • Ultrasound-Guided Biopsy Procedures: The needle is frequently used in conjunction with ultrasound imaging to guide accurate needle placement for obtaining tissue samples from deep organs or hard-to-reach areas.

  • Liver Biopsy: For sampling liver tissue to diagnose conditions like cirrhosis, hepatitis, or liver tumors.

  • Lymph Node Biopsy: For assessing lymph nodes for signs of lymphoma or metastatic cancer.

  • Thyroid Biopsy: Collecting thyroid tissue samples for diagnosing thyroid disorders or thyroid cancer.

  • Lung Biopsy: Aspiration of lung tissue in cases of suspected lung cancer or interstitial lung disease.

Usage Guidelines:

  1. Preparation: Prior to use, ensure the needle packaging is intact, and all other necessary equipment (such as gloves, local anesthetic, and suction devices) is available and sterile.

  2. Aseptic Technique: Open the sterile packaging and handle the needle using sterile techniques to maintain the sterility of the device.

  3. Needle Insertion: Insert the needle with the Chiba-style tip at the appropriate angle and depth, as guided by imaging, such as ultrasound or CT scan.

  4. Tissue Aspiration: Apply gentle suction to the needle to aspirate tissue samples. Ensure proper collection of the tissue for pathological examination.

  5. Post-Procedure Care: After the biopsy, remove the needle carefully and apply appropriate pressure to the biopsy site to prevent bleeding.

  6. Disposal: Dispose of the needle and any other single-use components according to the healthcare facilitys protocols for biohazardous waste.

Certifications and Safety Standards:

The CareFusion CHI1815 Chiba FNA Needle is manufactured to meet global medical device regulations, including FDA approval, ensuring it is safe for clinical use. It is made from biocompatible, high-grade stainless steel and meets the necessary quality standards for use in sterile environments.

Comparison with Competitor Products:

Compared to other fine needle aspiration products, the CareFusion CHI1815 stands out for:

  • Chiba-Style Needle Tip: The sharp, tapered Chiba-style tip allows for precise, minimally invasive tissue sampling, reducing trauma to surrounding tissue and improving the quality of the sample.

  • Stainless Steel Durability: The needles stainless steel construction ensures both sharpness and durability, preventing bending or dulling during the aspiration process.

  • Single-Use and Sterile: Unlike reusable biopsy needles, this needle is single-use, eliminating the need for cleaning or reprocessing and ensuring the highest level of infection control.

  • Sterile, Individually Packaged: The individual sterile packaging ensures that each needle is free of contaminants until it is used, guaranteeing maximum safety for both the patient and healthcare provider.

Typical User Profile and Application Scenarios:

The CareFusion CHI1815 Chiba FNA Needle is typically used by healthcare professionals, including:

  • Interventional Radiologists: For performing biopsies of deep tissues using ultrasound or CT guidance.

  • Pathologists: To collect tissue samples for cytology and histology.

  • Surgeons: In situations requiring biopsies of hard-to-reach areas or for minimally invasive tissue collection.

  • Oncologists: For diagnosing and staging cancers by obtaining tissue from suspected tumor sites.

  • Respiratory Therapists: For lung tissue biopsy when dealing with interstitial lung disease or cancer.

Best Practices for Use and Maintenance:

  • Proper Handling: Ensure that the needle is handled in a sterile manner, and aseptic technique is maintained at all times.

  • Regular Monitoring: Observe the patient during the procedure for any signs of complications such as excessive bleeding, pneumothorax (in lung biopsies), or infection.

  • Follow Infection Control Protocols: Use appropriate infection control procedures to ensure the safety of the patient and healthcare staff.

  • Safe Disposal: Ensure that the needle and all other single-use components are disposed of in accordance with institutional or national biohazard waste guidelines.

Regulatory and Safety Information:

The CareFusion CHI1815 Chiba FNA Needle is intended for single use only. The needle is pre-sterilized and should be disposed of immediately after use to prevent contamination. Reuse of the needle is prohibited and can pose risks to patient safety.

How to Order:

To order the CareFusion CHI1815 Chiba FNA Needle:

  1. Contact your preferred medical supply distributor.

  2. Specify the product code CHI1815 and the desired quantity.

  3. Complete the order process to receive the product.

For Bulk Orders or Inquiries:

For bulk orders or further assistance, contact CIA Medical customer service at (312) 275-5850 or use the contact form available on the CIA Medical website.

Related Products