Carefusion DST-2 - Genesis Non-Cellulose Sterilization Filter, 15.2 x 22.9 cm (6" x 9"), 500/BX

Carefusion # DST-2 - Genesis Non-Cellulose Sterilization Filter, 15.2 x 22.9 cm (6
Part Number Carefusion DST-2
SKU Number CIA1088982
Sell Unit BOX
Ships Within Special Order
List Price $157.29
Enter a valid quantity
Product Description

Carefusion DST-2 - Genesis Non-Cellulose Sterilization Filter, 15.2 x 22.9 cm (6" x 9"), 500/BX

The CareFusion DST-2 Genesis Non-Cellulose Sterilization Filter is a high-performance filter designed for use with Genesis sterilization containers. Measuring 15.2 x 22.9 cm (6" x 9"), this single-use filter is constructed from non-cellulose material, ensuring compatibility with various sterilization methods, including steam, ethylene oxide (EO), and STERRAD systems. Its design facilitates effective sterilant penetration while maintaining a robust microbial barrier, crucial for maintaining instrument sterility during storage and transport.

Cat. NoSizeQty/Box
DST-29in x 6in (23cm x 15.2cm)500

Key Benefits

  • Versatile Sterilization Compatibility: Suitable for steam, EO, and STERRAD sterilization processes, offering flexibility across different sterilization protocols.

  • Enhanced Microbial Barrier: Provides a reliable barrier against microorganisms, ensuring the sterility of surgical instruments post-sterilization.

  • Non-Cellulose Construction: Reduces the risk of particulate contamination and is compatible with a wide range of sterilization methods.

  • Single-Use Design: Minimizes cross-contamination risks and supports infection control practices.

  • Standardized Sizing: The 15.2 x 22.9 cm (6" x 9") dimensions are compatible with standard Genesis sterilization containers, facilitating easy integration into existing systems.

Compatibility and Applications
The DST-2 filter is specifically designed for use with Genesis sterilization containers. Its compatibility with multiple sterilization methods makes it suitable for various healthcare settings, including hospitals, surgical centers, and clinics, where maintaining instrument sterility is paramount.

Usage Guidelines

  1. Preparation: Ensure the Genesis sterilization container is clean and dry before filter application.

  2. Filter Placement: Place the DST-2 filter in the designated area within the container, ensuring full coverage of the vent area.

  3. Sterilization: Proceed with the chosen sterilization method (steam, EO, or STERRAD), following standard operating procedures.

  4. Post-Sterilization: After the sterilization cycle, inspect the filter for integrity before storage or transport of the container.

  5. Disposal: Dispose of the used filter according to institutional guidelines for medical waste.

Certifications, Safety Standards, and Regulatory Approvals
The CareFusion DST-2 filter complies with industry standards for sterilization accessories. Its non-cellulose composition aligns with best practices for sterilization processes, ensuring safety and efficacy in maintaining instrument sterility.

Comparison with Competitor Products
Compared to cellulose-based filters, the DST-2's non-cellulose construction offers superior resistance to moisture and reduces the risk of particulate contamination. Its compatibility with multiple sterilization methods provides an advantage over filters limited to a single sterilization process.

Typical User Profile and Application Scenarios
This product is intended for use by sterile processing department personnel, surgical technologists, and other healthcare professionals responsible for instrument sterilization. It is particularly beneficial in high-volume surgical settings where maintaining sterility and preventing cross-contamination are critical.

Best Practices for Use and Maintenance

  • Single Use: Do not reuse filters; always replace with a new filter for each sterilization cycle.

  • Storage: Store filters in a clean, dry environment to maintain their integrity until use.

  • Inspection: Regularly inspect filters for damage or contamination before use.

  • Training: Ensure all personnel are trained in proper filter application and disposal procedures.

Regulatory and Safety Information
The DST-2 filter is manufactured by CareFusion, a reputable company known for producing high-quality medical devices. It meets regulatory requirements for sterilization accessories and is designed to support infection control and patient safety initiatives.

How to Order
To purchase the CareFusion DST-2 Genesis Non-Cellulose Sterilization Filter (500 per box), add the product to your cart on the CIA Medical website and proceed to checkout. For bulk orders or inquiries, contact CIA Medical customer service at (312) 275-5850 or use the contact form on the product page. Our team is available to assist with volume pricing, product availability, and any additional information you may require.