(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Carefusion TIN3018 - Bone Marrow Aspiration Needle Sternal/Iliac, Adjustable Length 2679 mm, 18G x 3", 10/CS

Carefusion # TIN3018 - Bone Marrow Aspiration Needle  Sternal/Iliac, Adjustable Length 2679 mm, 18G x 3
Part Number Carefusion TIN3018
SKU Number CIA7014006
Sell Unit CASE
Ships Within Special Order
List Price $415.65
Enter a valid quantity
Product Description

Carefusion TIN3018 - Bone Marrow Aspiration Needle Sternal/Iliac, Adjustable Length 2679 mm, 18G x 3", 10/CS

The Carefusion TIN3018 Bone Marrow Aspiration Needle is a precision-engineered, sterile, single-use device designed for safe and efficient sternal or iliac crest bone marrow aspiration. Featuring an 18-gauge stainless steel cannula and an adjustable depth range of 26 mm to 79 mm, this 3-inch needle offers versatility and controlled penetration for adult diagnostic procedures.

Engineered with an ergonomic handle and depth-adjustable guard, the TIN3018 provides physicians with a high degree of precision, control, and comfort during bone marrow sampling, minimizing patient discomfort and procedural complications.

Key Benefits:

  • Adjustable Penetration Depth (2679 mm): Allows clinicians to fine-tune insertion depth based on patient anatomy and site of access, improving accuracy and safety.

  • Sharp 18G Stainless Steel Cannula: Ensures clean bone entry with reduced resistance, facilitating effective marrow extraction.

  • Ergonomic Handle Design: Provides secure grip and control during aspiration, enhancing user comfort and stability.

  • Single-Use and Sterile: Minimizes infection risk and eliminates reprocessing requirements, supporting infection control protocols.

  • Versatile Application Sites: Suitable for both sternal and iliac crest access, offering procedural flexibility based on clinical need.

Compatibility and Applications:
The Carefusion TIN3018 is compatible with:

  • Standard bone marrow aspiration syringes

  • Sternal and iliac access in adult patients

  • Radiological guidance tools (if needed)

Typical use cases include:

  • Hematologic diagnostics for conditions such as leukemia, lymphoma, anemia, and myeloma

  • Bone marrow donor evaluations

  • Oncology and hematology clinics, hospitals, and specialized diagnostic centers

Usage Guidelines:

  • Use aseptic technique when handling and inserting the needle.

  • Select the appropriate access site (sternal or iliac crest) based on patient assessment.

  • Adjust the depth guard between 26 mm and 79 mm to suit the patients anatomy.

  • Insert the needle using controlled, rotational motion until bone entry is achieved.

  • Aspirate marrow using a compatible syringe, then withdraw and dispose of the needle in a sharps container.

  • For detailed procedural guidance, refer to the product insert or institutional protocol.

Certifications, Safety Standards, and Regulatory Approvals:

  • FDA-cleared for human diagnostic use

  • CE Marked to meet European medical device safety standards

  • Manufactured under ISO 13485-certified quality management system

  • Constructed from biocompatible, latex-free materials

  • Complies with all relevant ASTM standards for bone marrow biopsy devices

These certifications confirm that the product adheres to global standards for safety, sterility, and diagnostic accuracy.

Comparison with Competitor Products:
Unlike generic aspiration needles, the Carefusion TIN3018 offers:

  • Adjustable depth range, enabling use on a broader range of patient anatomies

  • Durable, high-sharpness 18G cannula, which reduces patient discomfort during insertion

  • Trusted Carefusion quality assurance, making it a preferred tool among clinicians

  • Ergonomic grip design not always available in lower-cost alternatives

Its combination of precision, adjustability, and comfort makes it a standout tool for demanding bone marrow procedures.

Typical User Profile and Application Scenarios:
Commonly used by:

  • Hematologists and oncologists

  • Interventional radiologists

  • Internal medicine specialists

  • Hospital diagnostic lab professionals

Scenarios include:

  • Bone marrow aspiration procedures for disease staging, diagnosis, or transplant evaluation

  • Inpatient and outpatient hematology units

  • Oncology and bone marrow transplant centers

Best Practices for Use and Maintenance:

  • Always verify sterility before use and inspect for packaging damage.

  • Select the correct insertion depth based on body type and target site.

  • Ensure proper patient positioning to facilitate access and minimize discomfort.

  • Use gentle, rotational motion for insertion and firm pressure for marrow aspiration.

  • Discard the needle in an approved sharps container immediately after use.

Regulatory and Safety Information:
This product is compliant with all hospital-grade regulatory and safety standards, and is designed for single-patient use only to avoid cross-contamination. Safety markings and depth indicators ensure controlled, precise use during all procedures.

How to Order:
To purchase the Carefusion TIN3018 Bone Marrow Aspiration Needle (18G x 3", 2679 mm adjustable), add the item to your cart and proceed through CIA Medicals secure checkout system.

For questions regarding product compatibility, clinical use, or bulk purchasing, please contact CIA Medicals customer service at (312) 275-5850 or use the contact form on this page. Our experienced team is available to assist with your procedural supply needs.