(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Medline DYND160718 - TRAY, FOLEY, ERASE CAUTI, 100%SILI, 18FR10ML, 10 EA/CS

Medline # DYND160718 - TRAY, FOLEY, ERASE CAUTI, 100%SILI, 18FR10ML, 10 EA/CS
Part Number Medline DYND160718
SKU Number CIA1191482
Sell Unit EACH
Ships Within 24 Hours
List Price Call for Pricing
Product Description

Medline DYND160718 - TRAY, FOLEY, ERASE CAUTI, 100%SILI, 18FR10ML, 10 EA/CS

Trays: One-Layer Tray with Drain Bag and 100% Silicone Foley Catheter, 18 Fr, 10 mL, with 2,000 mL Drain Bag

Medline's patented One Layer Foley catheter tray design intuitively leads healthcare workers through established best practices. This unique design also includes labeling and instructions, making it easier to do the right thing. Maximize safety and comfort with our 100% silicone Foley catheters.

  • Features Medlines One Layer Foley Catheter Tray to help ensure best practices are followed
  • Completely inert for less tissue irritation and encrustation during extended periods of indwelling use
  • Foley catheter has bullet-shaped tip for easier insertion and less buckling
  • Large, smooth eyes for maximum comfort
  • Not made with natural rubber latex

Why Switch to 100% Silicone?

Health care professionals have been using silicone-based medical devices to set patients on the road to recovery. Here are five reasons why silicone is the better way to go when compared to other indwelling urinary catheter material types:

  • Eliminates risk of latex sensitization or reaction
  • Helps reduce swelling and other inflammatory responses
  • Slows bacterial migration
  • Improves urine flow and drainage
  • Helps decrease encrustations and blockages

Safeguard Against Latex Sensitization

Diminish Patient Inflammatory Responses

Lower the Risk of Bacterial Migration

Products made with Natural Rubber Latex (NRL)
contain variable amounts of proteins that can be inhaled
or absorbed by the skin, and may cause reactions
ranging from contact dermatitis to life-threatening
allergic reactions. Moreover, no method or test exists
to show a latex-based product is, in fact, safe.

Data shows the chance of a latex-sensitive patient
coming to a hospitals door escalates daily. An even
greater risk is at hand for the healthcare professional,
as continued exposure to NRL can lead to the development
of latex-related sensitivities that can become so severe
they can affect the clinicians ability to work.

Silicone is one of the most thoroughly tested and
widely-used groups of biomaterials known for its
intrinsic biocompatibility.4 Therefore, Medline 100%
silicone Foley catheters are a smarter alternative
for your patients to reduce instances of:

    • Urethritis
    • Urethral stricture6
    • Swelling
    • Discomfort
    • Other inflammatory reactions

Catheter-associated urinary tract infections (CAUTI)
account for 30% of hospital-acquired infections.7
Many cases of CAUTI are caused by organisms that migrate from
the urethral meatus-catheter interface along the external
surface of the catheter into the bladder.

One study found that 100% silicone Foley catheters,
like the ones available from Medline, had less potential
for bacterial migration when compared to latex catheters,
effectively shielding your patients against these types
of complications.

Increase Drainage

Proper flow through a Foley catheter is necessary to maintaining an empty bladder. Medlines 100% silicone Foley catheter was designed to have a larger drainage lumen than a latex Foley catheter in order to maximize urine flow. Medlines design also allows the clinician to deliver vigorous irrigation without the risk of collapsing the lumen.

A flow rate test was conducted comparing Medlines 16 Fr 100% silicone Foley catheter to the industry-leading 16 Fr latex catheter and 100% silicone catheter. The results speak for themselves.


Designed By Nurses for Nurses, the Patented One Layer Tray Helps Clinicians Consistently Follow Aseptic Insertion Technique

The IUC Standardization Bundle is designed to reinforce the limitation of IUC use to only when necessary, and facilitates best practice insertion technique. The cornerstone of the bundle is a patented one layer tray that helps staff intuitively follow aseptic technique and minimize variance. Designed by nurses for nurses, the tray guides clinicians, left to right, through the insertion process. Components are organized in order of use, minimizing the risk of contamination.

The High Price of CAUTIs

Catheter-associated urinary tract infections (CAUTIs) are one of the most common healthcare-associated infections (HAIs) and account for more than 15% of all HAIs reported by hospitals. They are expensive in both human and financial terms. CAUTIs cause patient discomfort, discharge delays, increased mortality, higher costs and lower hospital reimbursement.

The Human Cost of CAUTIsThe Financial Cost of CAUTIs
1,000,000 estimated number of CAUTIs that occur
annually in hospitals and nursing homes
$7,670 the attributable cost of CAUTI
for Medicare patients
9,000 approximate number of deaths
associated with CAUTI annually
$10,197 the attributable cost of CAUTI
for Medicare patients in the ICU
2.5 million estimated number of catheters placed
without an appropriate indication
$500 million annual cost of CAUTI to
healthcare system

Why CAUTI still happens.

Putting evidence into practice isnt easy. Thats why evidence-based practices arent necessarily implemented right away-even when they substantially reduce infection risk.

Competing priorities.

Initiatives to prevent CAUTI often have to compete with
other priorities that take time and put demands on staff.

"This is how weve always done it."

Caregiver and cultural biases for longstanding care
routines are often resistant to change.

Nursing workload.

Some nurses prefer indwelling urinary catheters (IUCs),
saying its easier to collect a specimen, and the patient
can rest more. Others think catheters save time because
they dont have to assist patients with toileting.

Patient or family request.

A family member may request an IUC because their loved one
cant get up or walk. Incontinent patients will sometimes talk
their doctor or nurse into keeping the catheter in.

Related Products