Carefusion PP1356 - Universal Coaxial Introducer Needle 13G x 6cm, Precision-Guided Access, 10/CS

Carefusion # PP1356 - Universal Coaxial Introducer Needle  13G x 6cm, Precision-Guided Access, 10/CS
Part Number Carefusion PP1356
SKU Number CIA1016231
Sell Unit CASE
Ships Within 24 Hours
List Price $249.79
Enter a valid quantity
Product Description

Carefusion PP1356 - Universal Coaxial Introducer Needle 13G x 6cm, Precision-Guided Access, 10/CS

The Carefusion PP1356 is a Universal Coaxial Introducer Needle measuring 13-gauge by 6 centimeters, designed for secure, precise access during percutaneous procedures. This needle features a sharp beveled tip for smooth tissue penetration and a coaxial design that facilitates the introduction of instruments such as biopsy needles, guidewires, or catheters through a stable pathway. Its universal compatibility allows it to integrate seamlessly with various interventional imaging systems and procedural setups.

Trusted in radiology, oncology, and surgical environments, the PP1356 is engineered to minimize trauma while maintaining alignment accuracy throughout the procedure.

ManufacturerPP1356
ApplicationCoaxial Introducer Needle
Gauge13.5 Gauge
Handle MaterialPlastic
Length6 cm Length
Needle MaterialStainless Steel
Needle StyleUniversal Coaxial
SterilitySterile
UsageSingle Use

Key Benefits

  • Coaxial Design: Allows for multiple instrument insertions through a single access point, reducing patient trauma.

  • Sharp Beveled Tip: Provides clean entry with minimal resistance, enhancing procedural accuracy.

  • 13G Size with 6cm Length: Optimized for intermediate-depth tissue access, balancing control and reach.

  • Radiopaque Markings: Support real-time visualization under fluoroscopy or CT guidance.

  • Sterile, Single-Use Construction: Ensures patient safety and infection control compliance.

Compatibility and Applications
Compatible with:

  • Biopsy needles (e.g., core or fine needle aspiration)

  • Guidewires and dilators

  • Introducer sets and vascular access kits

Used in:

  • CT-guided or ultrasound-guided interventional radiology

  • Oncology procedures for lesion targeting or biopsy

  • Vascular access in surgical and critical care settings

  • Minimally invasive soft tissue interventions

Usage Guidelines

  • Ensure the needle is compatible with the planned device or instrument to be introduced.

  • Use sterile technique when inserting through skin and soft tissue.

  • Confirm placement with appropriate imaging modality before introducing secondary instruments.

  • Once the procedure is completed, remove and discard according to sharps disposal protocol.

Certifications, Safety Standards, and Regulatory Approvals

  • FDA-cleared for use in percutaneous and imaging-guided access procedures

  • CE Marked for international compliance

  • Manufactured under ISO 13485 standards, guaranteeing medical-grade production and traceability

  • Compliant with ASTM F640/F899 for surgical needle materials and safety

These certifications underscore the device's quality, precision, and safety in invasive procedures.

Comparison with Competitor Products
Compared to generic introducer needles, the Carefusion PP1356 offers:

  • More stable coaxial performance, reducing tissue disruption during repeated insertions

  • Broader compatibility with instruments across specialties

  • Improved user confidence through sharpness, build integrity, and imaging visibility

Its universal application makes it a go-to introducer across a wide range of hospital departments.

Typical User Profile and Application Scenarios
Used by:

  • Interventional radiologists

  • Oncologists and biopsy specialists

  • Vascular surgeons and anesthesiologists

  • CT and ultrasound-guided procedure teams

Ideal for:

  • Percutaneous lesion targeting and biopsy

  • Soft tissue mass sampling

  • Placement of guidewires or drainage catheters

  • Image-guided interventions requiring repeat access through a single tract

Best Practices for Use and Maintenance

  • Store in a sterile environment until use.

  • Always confirm needle placement via imaging before proceeding.

  • Avoid reusing; designed for one-time application only.

  • Dispose immediately in sharps container post-procedure.

  • Use appropriate PPE and follow institutional safety protocols for invasive access.

Regulatory and Safety Information
Sterile, single-use device. Latex-free. For use by trained medical professionals under imaging guidance. Complies with global standards for procedural access safety and performance.

How to Order
To order the Carefusion PP1356 Universal Coaxial Introducer Needle (13G x 6cm), add the item to your cart on CIA Medical and follow the secure checkout process.
For procurement inquiries, technical support, or compatibility assistance, contact CIA Medical customer service at (312) 275-5850 or use the contact form on this page.

Related Products