(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Progeny-Midmark 30-08004 - JB-70 POWER PCB ASSEMBLY

JB-70 POWER PCB ASSEMBLY
Part Number Progeny-Midmark 30-08004
SKU Number CIA2431461
Sell Unit EACH
Ships Within Special Order
List Price $527.21
Enter a valid quantity
Product Description

Progeny-Midmark 30-08004 - JB-70 POWER PCB ASSEMBLY

The Midmark 30-08004 JB-70 Power PCB Assembly is a critical internal electrical control component designed for reliable power management within compatible Midmark medical equipment systems. This factory-specified replacement board regulates electrical distribution, stabilizes voltage flow, and ensures consistent device performance during clinical operation.

Medical equipment depends heavily on uninterrupted and properly controlled electrical communication between internal subsystems. The JB-70 power PCB assembly serves as the central electrical routing and protection interface, helping maintain operational integrity while safeguarding sensitive electronic modules from power fluctuations.

Manufactured to precise tolerances, the board integrates circuit protection, controlled output distribution, and device communication functions. It restores equipment functionality when an original board has failed due to wear, voltage surge, age-related degradation, or environmental exposure.

Key Benefits

This replacement assembly provides dependable restoration of power regulation performance and supports safe, stable clinical workflow.

  • Restores original equipment power distribution performance
  • Helps prevent electrical interruptions during patient procedures
  • Protects connected internal components from voltage irregularities
  • Factory-spec fit ensures direct installation compatibility
  • Supports consistent operation across extended clinical schedules
  • Reduces unexpected downtime and service calls
  • Maintains proper communication between electrical subsystems
  • Improves long-term equipment reliability and lifespan

Compatibility and Applications

The Midmark 30-08004 power PCB assembly is intended for use in designated Midmark systems utilizing the JB-70 electrical platform. It functions as a primary internal control board responsible for regulated electrical routing and equipment stability.

Typical applications include:

  • Medical examination tables
  • Procedure chairs
  • Powered patient positioning equipment
  • Motorized clinical furniture systems
  • Diagnostic and treatment room equipment

This component should only be installed in compatible equipment models confirmed through service documentation or qualified technical verification.

Usage Guidelines

Installation must be performed by trained biomedical technicians or qualified service personnel familiar with medical electrical equipment repair procedures.

Before installation:

  • Disconnect all power sources completely
  • Follow lockout and tagout safety procedures
  • Discharge residual stored electrical energy
  • Use anti-static handling precautions

During installation:

  • Handle the board by edges only
  • Avoid contact with circuitry or solder points
  • Verify connector orientation before attachment
  • Ensure proper mounting alignment
  • Secure wiring harness connections firmly

After installation, perform full operational testing to confirm normal device performance and correct electrical response.

Certifications and Safety Standards

The PCB assembly is manufactured to meet medical equipment electrical safety expectations and supports compliance with recognized healthcare equipment performance standards when installed properly.

  • Supports equipment electrical safety operation requirements
  • Designed for controlled clinical environments
  • Manufactured using medical-grade component tolerances
  • Compatible with regulated healthcare facility maintenance protocols

Comparison with Competitors

Unlike generic aftermarket circuit boards, the Midmark specified PCB assembly maintains correct voltage mapping and communication protocols required by proprietary systems. Generic boards may physically fit but often lack calibration precision, leading to intermittent performance issues.

The original replacement assembly ensures:

  • Exact electrical load handling
  • Correct motor control response
  • Proper system communication signals
  • Longer operational stability

Using non-specified boards frequently results in diagnostic errors, unpredictable behavior, or shortened equipment lifespan. This OEM-matched replacement eliminates those risks.

Typical User Profile and Application Scenarios

This component is commonly used by biomedical engineers, clinical equipment maintenance teams, and healthcare service contractors responsible for maintaining operational medical furniture and powered patient equipment.

Typical facilities include:

  • Hospitals
  • Outpatient surgery centers
  • Primary care clinics
  • Specialty treatment practices
  • Diagnostic centers
  • Long-term care facilities

It is particularly important in environments where equipment downtime directly impacts patient scheduling and workflow efficiency.

Best Practices for Use and Maintenance

To maximize performance and longevity, proper installation and preventive maintenance procedures should be followed.

  • Inspect surrounding wiring during replacement
  • Check connectors for corrosion or looseness
  • Maintain stable power supply conditions
  • Avoid exposure to excessive humidity
  • Ensure adequate ventilation within equipment housing
  • Document replacement date for maintenance tracking

Routine equipment inspections help identify early electrical wear and prevent sudden operational failure.

Regulatory and Safety Information

This component is intended solely as a service replacement part within compatible medical equipment systems. It is not a standalone medical device and must be installed within manufacturer design parameters.

Installation by unqualified personnel may result in equipment malfunction, electrical hazard, or voided equipment compliance. Always follow facility maintenance procedures and applicable safety regulations.

How to Order

To purchase the Midmark 30-08004 JB-70 Power PCB Assembly or to confirm compatibility with your equipment, contact CIA Medical customer support at (312) 275-5850. Our specialists can assist with product identification, availability, and technical ordering support.