(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Progeny-Midmark 30-A2071 - HORIZ LONG ARM F/PREVA

HORIZ LONG ARM F/PREVA
Part Number Progeny-Midmark 30-A2071
SKU Number CIA2431519
Sell Unit EACH
Ships Within Special Order
List Price $611.28
Enter a valid quantity
Product Description

Progeny-Midmark 30-A2071 - HORIZ LONG ARM F/PREVA

The Midmark 30-A2071 Horizontal Long Arm is a precision-engineered support component designed specifically for Preva dental delivery systems. This structural arm provides extended reach and stable positioning for mounted delivery equipment, helping clinicians work comfortably while maintaining optimal access to the treatment area. Built to integrate seamlessly with compatible Midmark dental units, the arm allows smooth horizontal movement and dependable support during daily procedures.

Constructed from durable clinical-grade materials, the arm maintains structural integrity even under continuous professional use. Its extended length supports flexible room layouts and operator positioning, enabling dental teams to maintain proper ergonomics without compromising workflow efficiency. The component is manufactured to original equipment specifications, ensuring dependable performance and consistent fit within existing Midmark configurations.

Key Benefits

The extended horizontal reach improves clinician positioning by bringing instruments closer to the working field, reducing unnecessary body movement during procedures. Smooth pivot action enables controlled motion, helping maintain stability while adjusting equipment placement. This supports patient comfort and allows uninterrupted focus during treatment.

The durable metal construction resists wear from daily cleaning and repeated adjustments, contributing to long service life. Proper weight distribution minimizes strain on mounting points, reducing maintenance frequency for the overall delivery system. The components precise engineering also helps maintain alignment of attached instruments, improving usability and reliability.

By supporting ergonomic workflow, the arm contributes to reduced operator fatigue over long clinical sessions. Its dependable movement allows assistants and dentists to quickly reposition tools, increasing treatment efficiency and minimizing downtime between procedures.

Compatibility and Applications

The Midmark 30-A2071 Horizontal Long Arm is designed for use with Preva dental delivery units and compatible Midmark mounting assemblies. It functions as a support extension for delivery heads, instrument trays, and mounted dental equipment that require adjustable horizontal positioning.

Typical applications include general dentistry operatories, hygiene rooms, specialty treatment environments, and teaching clinics where flexible equipment positioning is essential. The arm allows clinicians to adapt to different chair orientations, right or left handed operation, and varied patient positioning requirements.

The component is intended for professional installation into existing compatible systems and is commonly used during replacement, refurbishment, or equipment reconfiguration projects within dental facilities.

Usage Guidelines

Installation should be performed by qualified service personnel familiar with Midmark equipment systems. Proper mounting alignment ensures smooth movement and prevents unnecessary stress on connecting hardware. After installation, verify full range of motion and confirm secure attachment before patient use.

During operation, adjust the arm gradually using controlled movement rather than sudden force. Equipment should remain within recommended weight limits to maintain proper balance and performance. Regular visual inspection should be conducted to confirm stable attachment and consistent movement.

If resistance or misalignment is detected, discontinue use and inspect mounting connections before continuing clinical procedures.

Certifications and Safety Standards

The component is manufactured according to original equipment performance specifications and is designed to support compliance with applicable dental equipment safety requirements. When installed within an approved Preva system, it contributes to maintaining overall equipment safety and operational reliability in clinical environments.

Use within professional dental facilities helps support regulatory compliance for properly maintained patient care equipment. Installation and servicing should follow facility safety protocols and manufacturer service recommendations.

Comparison with Competitors

Unlike generic replacement arms that may offer approximate fit, the Midmark 30-A2071 provides precise compatibility with Preva systems. Accurate alignment reduces wobble, improves stability, and preserves proper instrument positioning. Generic alternatives often require adjustment modifications that may compromise long term performance or mounting safety.

The original equipment design supports consistent motion across the entire horizontal range, whereas non matched components may create uneven movement or premature wear. The balanced structural engineering also distributes load correctly across the mounting assembly, reducing stress on connected components.

Facilities seeking reliability and reduced maintenance cycles benefit from an exact replacement component rather than universal substitutes.

Typical User Profile and Application Scenarios

This component is commonly used by dental clinics upgrading or restoring Preva delivery units. Dental service technicians frequently install the arm during refurbishment projects to restore original functionality of treatment rooms. Educational institutions and group practices also use the part when adapting operatories for ergonomic compliance.

Clinicians who require extended reach for instrument positioning, including orthodontists and general dentists working in multi position environments, benefit from the improved flexibility. High patient volume practices particularly value dependable movement and consistent positioning during repeated daily procedures.

Best Practices for Use and Maintenance

Routine cleaning should be performed using approved surface disinfectants suitable for dental equipment finishes. Avoid excessive liquid exposure near pivot points to maintain smooth mechanical movement. Periodic inspection of mounting hardware helps detect early signs of loosening or wear.

Lubrication should only be performed according to service recommendations and by qualified personnel if required. Overloading attached delivery equipment should be avoided to preserve alignment and prevent premature wear.

Maintaining proper balance of attached instruments helps ensure consistent motion and reduces long term stress on the mounting assembly.

Regulatory and Safety Information

This component is intended for professional dental equipment use only and should be installed by trained technicians. Proper installation is essential to maintain safe operation of the delivery system. Facilities must follow applicable equipment maintenance guidelines and safety inspection procedures.

Routine preventive maintenance of the entire delivery unit should include evaluation of arm stability and movement. Any unusual movement, noise, or instability should be addressed before further patient treatment.

How to Order

To order the Midmark 30-A2071 Horizontal Long Arm for Preva dental system, contact CIA Medical customer service at (312) 275-5850. A representative will assist with compatibility verification, pricing information, and shipping arrangements to ensure accurate fulfillment for your facility.

Related Products