(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Progeny-Midmark 60-P0014 - PASSIVE BLADE, COLLIMATOR

PASSIVE BLADE, COLLIMATOR
Part Number Progeny-Midmark 60-P0014
SKU Number CIA2308008
Sell Unit EACH
Ships Within Special Order
List Price $40.73
Enter a valid quantity
Product Description

Progeny-Midmark 60-P0014 - PASSIVE BLADE, COLLIMATOR

The Midmark 60-P0014 Passive Blade, Collimator is a precision-engineered component designed to support accurate beam alignment and field limitation in compatible diagnostic imaging systems. As a critical element within the collimator assembly, this passive blade plays an essential role in shaping and controlling the X-ray beam to enhance image clarity while reducing unnecessary radiation exposure.

Manufactured to meet strict quality and performance standards, the 60-P0014 passive blade is constructed from durable materials that maintain structural integrity under repeated clinical use. It is specifically engineered for seamless integration into Midmark imaging equipment, ensuring reliable operation and consistent beam restriction performance.

For healthcare facilities focused on maintaining optimal imaging accuracy and patient safety, the Midmark 60-P0014 Passive Blade offers dependable performance and precise compatibility with designated collimator assemblies.

Key Benefits

The Midmark 60-P0014 Passive Blade supports improved imaging accuracy by contributing to precise beam limitation. By properly restricting the X-ray field, it helps reduce scatter radiation, which can interfere with diagnostic image quality. This enhances the clarity and contrast of radiographic images.

Its durable construction ensures long-term reliability within high-usage medical environments. The blade is manufactured to exact specifications, allowing for accurate fit and smooth movement within the collimator mechanism.

In addition to supporting high-quality imaging outcomes, this component helps healthcare providers maintain compliance with radiation safety protocols by assisting in controlled beam shaping and exposure management.

Compatibility and Applications

The Midmark 60-P0014 Passive Blade is designed for use within compatible Midmark collimator assemblies in diagnostic imaging systems. It functions as part of the internal collimator mechanism responsible for adjusting the X-ray beam field.

This component is typically used in medical and veterinary imaging environments where precision radiography is required. Applications include general diagnostic imaging in outpatient clinics, specialty practices, ambulatory surgery centers, and imaging suites that utilize Midmark radiographic equipment.

Facilities performing routine X-ray examinations depend on properly functioning collimator blades to ensure consistent beam alignment and accurate field limitation. The 60-P0014 passive blade supports these operational requirements.

Usage Guidelines

Installation of the Midmark 60-P0014 Passive Blade should be performed by qualified biomedical technicians or authorized service professionals familiar with diagnostic imaging systems. Proper disassembly of the collimator housing and careful placement of the replacement blade are essential to maintain correct alignment.

After installation, technicians should verify smooth mechanical movement of the blade assembly and confirm proper beam restriction during system testing. Routine inspection of collimator performance is recommended as part of preventive maintenance schedules.

Only approved replacement parts should be used to ensure compatibility and maintain equipment integrity. Using original components helps preserve optimal imaging accuracy and long-term system reliability.

Certifications and Safety Standards

The Midmark 60-P0014 Passive Blade is manufactured in accordance with applicable medical device manufacturing standards. As a component used within regulated diagnostic imaging systems, it supports compliance with radiation control and safety guidelines when installed and maintained correctly.

Healthcare facilities should follow all federal, state, and local regulations regarding diagnostic imaging equipment maintenance. Routine service documentation and inspection records should be maintained to demonstrate ongoing compliance with safety protocols.

When integrated into properly maintained imaging equipment, this passive blade contributes to safe and controlled X-ray beam operation.

Comparison with Competitors

Compared to non-original or generic replacement parts, the Midmark 60-P0014 Passive Blade offers precise dimensional accuracy and verified compatibility with designated Midmark imaging systems. Generic components may not meet exact tolerances, potentially affecting beam alignment and image quality.

Original manufacturer components are designed specifically for the equipment in which they are installed. This ensures consistent fit, dependable performance, and reduced risk of premature wear or mechanical malfunction.

Facilities seeking to maintain manufacturer-level imaging performance and service reliability benefit from selecting genuine replacement parts rather than aftermarket alternatives.

Typical User Profile and Application Scenarios

This passive blade is typically ordered by biomedical service providers, imaging equipment maintenance teams, hospital facilities departments, and independent service organizations responsible for maintaining diagnostic radiology systems.

Common scenarios for replacement include routine preventive maintenance, repair following mechanical wear, or restoration of collimator functionality after performance degradation. Clinics experiencing inconsistent beam limitation or alignment issues may require inspection and potential replacement of internal collimator blades.

By ensuring proper collimator operation, healthcare providers can continue delivering high-quality diagnostic imaging services with confidence.

Best Practices for Use and Maintenance

To maintain optimal collimator performance, facilities should incorporate regular inspection of beam alignment and field limitation into their preventive maintenance programs. Any signs of mechanical resistance, inconsistent blade movement, or irregular beam shaping should be evaluated promptly.

Maintaining a clean internal environment within the collimator assembly helps prevent debris accumulation that could interfere with blade operation. Service technicians should follow manufacturer-recommended procedures when accessing internal components.

Documenting service activities and replacement dates supports long-term equipment lifecycle management and helps ensure uninterrupted imaging operations.

Regulatory and Safety Information

The Midmark 60-P0014 Passive Blade is intended for use within compatible diagnostic imaging systems operated by trained professionals. Installation and servicing should comply with all applicable equipment maintenance guidelines and radiation safety regulations.

Improper installation or use of non-compatible components may compromise imaging accuracy and radiation control. Always confirm compatibility with the specific equipment model before installation.

For regulatory compliance and patient safety, facilities should ensure that all imaging equipment components are maintained in accordance with established quality assurance programs.

How to Order

To order the Midmark 60-P0014 Passive Blade, Collimator, contact CIA Medical directly to confirm compatibility and availability. Our product specialists can assist with part verification and bulk purchasing requirements.

Call (312) 275-5850 to speak with a knowledgeable representative and place your order today. Prompt processing and reliable fulfillment help ensure your diagnostic imaging equipment remains fully operational.