-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
Carefusion RT210 - Dual-Limb Heated Breathing Circuit Kit with MR290 Complete Heated Circuit System for Optimal Humidification, 10/CS
The Carefusion RT210 Kit is a dual-limb heated breathing circuit system designed to deliver warm, humidified gases to patients undergoing mechanical ventilation. It includes the MR290 heated humidification chamber, enabling optimal respiratory gas conditioning and preventing mucosal drying during prolonged ventilatory support.
This complete, ready-to-use circuit system is ideal for use with heated humidifiers in adult critical care settings. Designed with high-quality, medical-grade materials, it supports both invasive and non-invasive ventilation, ensuring patient comfort and reducing complications such as secretion thickening and airway occlusion.
Key Benefits:
Complete Heated Circuit System: Includes inspiratory and expiratory limbs with integrated heaters and MR290 humidification chamber for full humidified respiratory support.
Reduces Airway Complications: Heated and humidified gases help maintain mucosal integrity, improving secretion clearance and minimizing tube occlusion risks.
Enhanced Patient Comfort: Minimizes dryness, irritation, and discomfort for ventilated patients, particularly during extended respiratory support.
Ready-to-Use Kit: Pre-assembled for quick setup, reducing staff workload and ensuring consistent humidification therapy.
High-Quality Materials: Biocompatible, latex-free components for safe use with sensitive patients.
This dual-limb heated circuit is essential for critical care units requiring efficient, high-performance humidified ventilation support.
Compatibility and Applications:
The RT210 breathing circuit kit is compatible with:
Fisher & Paykel MR850 and MR730 heated humidifiers
Most ICU-grade ventilators and respiratory support systems
Standard 22mm ventilator ports and humidifier connectors
Typical use cases include:
Adult ICU mechanical ventilation
Operating rooms and recovery areas
Emergency departments requiring respiratory intervention
Long-term ventilation care in hospitals and specialty clinics
Usage Guidelines:
Connect the MR290 chamber to the heated humidifier and fill with sterile water.
Attach the inspiratory and expiratory limbs to the appropriate ventilator ports.
Ensure all connections are secure and temperature probes are properly placed.
Monitor temperature and humidity settings on the humidifier to ensure patient safety.
Replace the circuit in accordance with facility infection control protocols or per manufacturer's recommendation (typically 7 days or per patient use).
Certifications, Safety Standards, and Regulatory Approvals:
FDA-registered Class II medical device
CE Marked for European regulatory compliance
Manufactured under ISO 13485 certified quality management systems
Compliant with ASTM and ISO standards for respiratory care and humidification safety
Latex-free and biocompatible materials used throughout
These credentials ensure consistent, high-quality performance in demanding clinical settings.
Comparison with Competitor Products:
Compared to generic heated circuits or single-limb systems, the Carefusion RT210 offers:
Superior humidification with MR290 chamber integration
Reduced circuit condensation, lowering risk of water pooling and circuit blockage
Dual-limb heated design, maintaining precise temperature and humidity throughout the patient interface
Easy installation and compatibility with major ventilator and humidifier systems
These advantages make it a preferred choice for critical respiratory support over standard or non-heated circuits.
Typical User Profile and Application Scenarios:
Used by:
Respiratory therapists
Critical care nurses and ICU clinicians
Anesthesia providers and operating room staff
Emergency medicine professionals
Scenarios include:
Patients with high oxygen or ventilatory needs
Post-operative respiratory support
Chronic respiratory failure with secretion management
Long-term mechanical ventilation in critical care settings
Best Practices for Use and Maintenance:
Always use sterile water in the MR290 chamber.
Check for proper limb heating and humidity control throughout ventilation.
Avoid kinking or compressing circuit limbs to ensure uninterrupted airflow.
Inspect for water accumulation and drain condensation safely as needed.
Replace circuit based on patient use or facility protocol to maintain hygiene and performance.
Store in a dry, temperature-controlled environment in original packaging before use.
Regulatory and Safety Information:
The Carefusion RT210 is engineered in compliance with international respiratory therapy standards, providing reliable, safe, and effective humidified ventilation. It is designed for single-patient use only, with clear usage labels and safety precautions to support infection control.
How to Order:
To purchase the Carefusion RT210 Dual-Limb Heated Breathing Circuit Kit with MR290, add the product to your cart and proceed through CIA Medicals secure online checkout system.
For large orders, clinical compatibility questions, or additional product support, contact CIA Medical at (312) 275-5850 or submit an inquiry through the contact form on this page. Our respiratory care specialists are available to assist with your setup and supply needs.