(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 100/102/050 - Tracheal Tube, Cuffed with Preloaded Stylet AIRCARE, 5.0mm, 10/bx

Tracheal Tube, Cuffed with Preloaded Stylet AIRCARE, 5.0mm, 10/bx
Part Number Smiths Medical 100/102/050
SKU Number CIA8069316
Sell Unit BOX
Ships Within Special Order
List Price $72.83
Enter a valid quantity
Product Description

Smiths Medical 100/102/050 - Tracheal Tube, Cuffed with Preloaded Stylet AIRCARE, 5.0mm, 10/bx

The Smiths Medical 100/102/050 Tracheal Tube with preloaded stylet is designed to support reliable airway management during intubation procedures. Featuring a 5.0 mm internal diameter and a cuffed design, this AIRCARE tracheal tube helps clinicians maintain a secure airway while reducing the risk of aspiration and air leakage. The integrated preloaded stylet assists with accurate placement, providing improved control during insertion.

Constructed from clear medical-grade materials, the tube allows clinicians to visually monitor condensation and airway status. The cuff provides a dependable seal within the trachea, helping ensure effective ventilation and oxygen delivery during surgical, emergency, and critical care procedures. Packaged in convenient boxes of 10, the device is designed for efficiency and reliability in fast-paced clinical environments.

Key Benefits

The cuffed tracheal tube design supports improved airway sealing, helping reduce the risk of aspiration while maintaining consistent ventilation. A preloaded stylet simplifies insertion and provides added control during intubation, especially in challenging airway situations. The clear tube construction improves visibility, allowing healthcare professionals to monitor airflow and condensation during use. The device is designed to deliver dependable performance in operating rooms, emergency departments, and intensive care settings.

Compatibility and Applications

This tracheal tube is compatible with standard airway management systems, including ventilators, breathing circuits, anesthesia machines, and manual resuscitation devices. It is commonly used for oral or nasal intubation procedures in hospitals, surgical centers, and emergency medical settings. The 5.0 mm tube size makes it suitable for pediatric or small airway applications where precise airway control is required.

Usage Guidelines

Prior to use, clinicians should verify tube integrity and ensure the cuff inflates properly. The preloaded stylet assists in guiding the tube during intubation and should be positioned appropriately before insertion. Once the airway is secured, the cuff should be inflated to achieve an adequate seal without exceeding recommended pressure levels. Continuous monitoring of patient ventilation and airway placement is recommended throughout the procedure.

Certifications and Safety Standards

The Smiths Medical AIRCARE tracheal tube is manufactured to meet stringent medical device quality and safety requirements. Production follows internationally recognized healthcare manufacturing standards to ensure consistent product performance. Materials used in the device are selected to support patient safety and clinical reliability in professional healthcare environments.

Comparison with Competitors

Compared with many standard endotracheal tubes, this model offers the convenience of a preloaded stylet, which reduces preparation time and improves control during insertion. The cuff design supports a dependable airway seal, while the clear tube construction provides improved visibility during ventilation monitoring. These features make it a practical choice for clinicians who require both efficiency and dependable airway management performance.

Typical User Profile and Application Scenarios

This tracheal tube is commonly used by anesthesiologists, emergency physicians, respiratory therapists, and critical care specialists. It is suitable for airway management in operating rooms, emergency departments, ambulatory surgery centers, and intensive care units. The device is also frequently used in trauma situations where rapid airway control is essential.

Best Practices for Use and Maintenance

The tracheal tube should remain in its sterile packaging until immediately before use. Clinicians should inspect the device for any signs of damage or defects before placement. Proper cuff pressure monitoring should be maintained to minimize tracheal injury risk while ensuring an adequate airway seal. After use, the device should be disposed of according to established clinical waste and infection control protocols.

Regulatory and Safety Information

This airway management device is intended for use by trained healthcare professionals. Proper intubation techniques and monitoring procedures should be followed to ensure patient safety. The product should be stored in a clean, dry environment and handled according to standard hospital infection control policies.

How to Order

The Smiths Medical 100/102/050 AIRCARE Tracheal Tube with Preloaded Stylet, 5.0 mm, is available in boxes of 10. Healthcare facilities, clinics, and medical distributors can order directly through CIA Medical. For product availability, pricing, and bulk purchasing information, contact CIA Medical at (312) 275-5850.

Related Products