Smiths Medical 100/103/035 - TRACHEAL TUBE CLEAR MURPHY AIRCARE UNCUFFED STYLET 3.5MM 10/BX

TRACHEAL TUBE CLEAR MURPHY AIRCARE UNCUFFED STYLET 3.5MM 10/BX
Part Number Smiths Medical 100/103/035
SKU Number CIA2465647
Sell Unit PACK
Ships Within Special Order
List Price $32.59
Enter a valid quantity
Product Description

Smiths Medical 100/103/035 - TRACHEAL TUBE CLEAR MURPHY AIRCARE UNCUFFED STYLET 3.5MM 10/BX

Equipped with a Murphy eye and supplied with a preloaded stylet, the AirCare tracheal tube is engineered for smooth insertion and consistent positioning during intubation procedures. Its uncuffed design makes it particularly suitable for pediatric and neonatal airway management where cuffless airway devices are often preferred. Each box contains ten sterile tubes, making it an efficient option for hospitals, emergency departments, operating rooms, and respiratory care units.

Key Benefits

  • Clear medical-grade PVC construction allows visual monitoring of condensation and secretions
  • Murphy eye design maintains airflow even if the distal tip becomes partially obstructed
  • Uncuffed design suitable for pediatric airway management and delicate airway structures
  • Preloaded stylet assists clinicians in achieving accurate tube placement
  • Smooth tube surface helps reduce trauma during insertion
  • Radiopaque line supports confirmation of tube placement using imaging
  • Sterile packaging ensures immediate readiness for clinical use
  • Packaged in convenient boxes of ten units for healthcare facilities

Compatibility and Applications

The Smiths Medical AirCare tracheal tube is designed for use in a variety of airway management scenarios across hospital and emergency settings. The 3.5 mm internal diameter is commonly used for pediatric airway procedures where precise airway control is required.

This tracheal tube can be used with standard airway management systems including manual resuscitators, ventilators, anesthesia machines, and breathing circuits. The integrated stylet helps clinicians guide the tube during placement while maintaining the correct shape for intubation.

Typical applications include emergency airway stabilization, anesthesia support during surgery, pediatric respiratory care, and intensive care ventilation management.

Usage Guidelines

Prior to use, healthcare professionals should verify the tube size and inspect the sterile packaging to ensure integrity. The device should be used only by trained clinicians experienced in airway management and intubation procedures.

The preloaded stylet should be shaped appropriately before insertion to assist with controlled placement through the vocal cords. Once the tube is correctly positioned within the trachea, the stylet must be carefully removed. Proper placement should then be confirmed using standard clinical methods such as auscultation, capnography, or imaging.

Following placement, the tube should be secured using appropriate fixation methods to prevent displacement during patient care.

Certifications and Safety Standards

The AirCare tracheal tube is manufactured in accordance with strict medical device quality standards to ensure safety and reliability in clinical environments. Production processes follow recognized healthcare manufacturing guidelines and quality management systems.

Each device is sterilized and packaged to maintain sterility until the moment of use. The materials used in the construction of the tube are biocompatible and suitable for short-term airway management procedures.

Comparison with Competitors

Compared with many standard tracheal tubes available on the market, the Smiths Medical AirCare series is known for its consistent material quality and dependable airway performance. The integrated Murphy eye improves airflow reliability compared with tubes that rely solely on the main distal opening.

The inclusion of a preloaded stylet offers additional convenience for clinicians, reducing the need for separate accessories during emergency airway procedures. The clear PVC design also enhances visualization compared with opaque alternatives.

Typical User Profile and Application Scenarios

This tracheal tube is commonly used by anesthesiologists, emergency physicians, respiratory therapists, and critical care specialists. Pediatric departments frequently rely on uncuffed tracheal tubes for airway management in young patients where cuffed devices may not be appropriate.

Healthcare facilities that regularly perform pediatric surgery, neonatal care, or emergency airway stabilization benefit from maintaining a supply of AirCare tracheal tubes in multiple sizes, including the 3.5 mm model.

Best Practices for Use and Maintenance

Tracheal tubes should always be stored in a clean and controlled medical environment to maintain product integrity. Clinicians should ensure that sterile packaging remains intact until the device is required for use.

During intubation procedures, careful technique should be used to avoid trauma to airway structures. The tube should be secured properly after placement and monitored regularly throughout ventilation or anesthesia procedures.

After use, the device should be disposed of according to healthcare facility infection control protocols and medical waste management guidelines.

Regulatory and Safety Information

This tracheal tube is intended for use by trained healthcare professionals in controlled clinical environments. The product is designed for single-use applications to prevent cross contamination and ensure patient safety.

All airway devices should be used in accordance with institutional protocols and airway management guidelines. Clinicians must verify correct tube placement and monitor patient ventilation throughout the procedure.