(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 100/105/030 - TUBE ENDOTRACHEAL NASAL UNCUFFED 3.0MM ID MAGILL PVC (10/BX)

Smiths Medical # 100/105/030 - TUBE ENDOTRACHEAL NASAL UNCUFFED 3.0MM ID MAGILL PVC (10/BX)
Part Number Smiths Medical 100/105/030
SKU Number CIA1073629
Sell Unit BOX
Ships Within Special Order
List Price $35.51
Enter a valid quantity
Product Description

Smiths Medical 100/105/030 - TUBE ENDOTRACHEAL NASAL UNCUFFED 3.0MM ID MAGILL PVC (10/BX)

The Smiths Medical 100/105/030 Nasal Endotracheal Tube is designed for secure airway management during nasal intubation procedures. Featuring a 3.0 mm internal diameter and a Magill-style curvature, this uncuffed tube supports smooth insertion through the nasal passage while maintaining effective ventilation. Constructed from medical-grade PVC, the tube offers the right balance of flexibility and structural integrity to ensure consistent airway patency during surgical or emergency care.

This nasal endotracheal tube is particularly suitable for pediatric airway management where an uncuffed design is preferred. Its clear construction allows clinicians to easily monitor condensation and airway status throughout the procedure. Supplied in a box of ten units, the product supports efficient stocking for hospitals, ambulatory surgery centers, and emergency departments.

Key Benefits

  • 3.0 mm internal diameter optimized for pediatric airway management
  • Magill curvature allows smoother navigation during nasal intubation
  • Medical-grade PVC construction ensures flexibility and patient comfort
  • Uncuffed design suitable for delicate airway structures
  • Clear tube design allows visual monitoring of condensation and airflow
  • Sterile packaging supports safe clinical use
  • Supplied in convenient boxes of ten for healthcare facilities

Compatibility and Applications

The Smiths Medical nasal endotracheal tube is compatible with standard ventilators, anesthesia machines, and breathing circuits commonly used in modern clinical environments. It is widely utilized in operating rooms, intensive care units, and emergency settings where reliable nasal airway access is required.

This device is particularly valuable for procedures involving oral surgery, maxillofacial surgery, or situations where oral intubation may interfere with the surgical field. Its design supports safe and controlled airway access while minimizing trauma to nasal tissues.

Usage Guidelines

The tube should be inserted by trained medical professionals following standard airway management protocols. Prior to insertion, clinicians should confirm the appropriate size for the patient and inspect the device for any visible defects. Proper lubrication is recommended to facilitate smoother passage through the nasal cavity.

Once positioned, placement should be verified using standard clinical methods such as auscultation and capnography. The tube should be secured properly to maintain airway stability throughout the procedure.

Certifications and Safety Standards

The Smiths Medical nasal endotracheal tube is manufactured according to strict medical device quality standards to ensure reliability and patient safety. Production processes follow recognized international manufacturing guidelines designed for sterile airway management devices used in clinical environments.

Each unit is packaged to maintain sterility until opened, helping healthcare facilities maintain compliance with infection control protocols.

Comparison with Competitors

Compared with other nasal endotracheal tubes on the market, this Smiths Medical model offers a well-balanced combination of flexibility, clarity, and anatomical design. The Magill curvature provides enhanced ease of insertion compared to straight tubes, while the PVC material offers a reliable level of flexibility that helps minimize patient discomfort.

Many competing products may lack the same clarity or consistent structural quality, making the Smiths Medical airway management line a trusted option among clinicians seeking dependable airway devices.

Typical User Profile and Application Scenarios

This nasal endotracheal tube is commonly used by anesthesiologists, respiratory therapists, emergency physicians, and critical care teams. It is particularly suitable for pediatric patients requiring controlled ventilation during surgery or respiratory support.

Healthcare facilities such as hospitals, outpatient surgical centers, and specialized pediatric clinics frequently rely on this device to maintain safe airway access during a wide range of procedures.

Best Practices for Use and Maintenance

Clinicians should always verify correct tube sizing and placement before initiating ventilation. Gentle insertion techniques and proper lubrication help reduce nasal trauma and improve patient comfort during intubation. After placement, the tube should be secured using approved fixation methods to prevent displacement.

As a single-use sterile device, the tube should be disposed of after use according to medical waste management regulations.

Regulatory and Safety Information

This airway management device is intended for professional medical use only and should be handled by trained healthcare personnel. The product is manufactured in accordance with applicable regulatory requirements for sterile medical devices used in airway management.

Clinicians should follow institutional guidelines and airway management protocols when using this device to ensure patient safety and optimal clinical outcomes.

How to Order

Healthcare providers and purchasing departments can order the Smiths Medical 100/105/030 Nasal Endotracheal Tube directly through CIA Medical. For pricing, availability, and bulk purchasing options, contact CIA Medical at (312) 275-5850 to speak with a product specialist who can assist with your order.

Related Products