Smiths Medical 100/127/055 - TUBE ENDOTRACHEAL ORAL/NASAL UNCUFFED 5.5MM ID MURPHY PREFORMED PVC (10/CS)

The Smiths Medical 100/127/055 Endotracheal Tube is a high-quality airway management device designed for reliable oral or nasal intubation procedures. Manufactured from medical-grade PVC and featuring a preformed design, this uncuffed endotracheal tube provides dependable airway access while maintaining patient comfort and clinical precision.

With a 5.5mm internal diameter and Murphy eye design, this tube enhances airflow and reduces the risk of complete airway obstruction. The preformed shape helps maintain tube positioning during procedures, making it particularly useful in operating rooms, emergency care, and intensive care settings. Each case contains ten sterile tubes, ensuring consistent availability for hospitals, surgical centers, and respiratory care providers.

Key Benefits

  • Preformed tube design helps maintain stable positioning during oral or nasal intubation
  • Murphy eye opening improves patient safety by providing an alternate airflow pathway
  • Medical-grade PVC construction ensures flexibility and durability
  • Smooth surface minimizes airway trauma during insertion and removal
  • Clear tube design allows easy visualization of condensation and airway secretions
  • 5.5mm internal diameter suitable for pediatric airway management
  • Sterile packaging maintains product integrity until use

Compatibility and Applications

This endotracheal tube is widely used in clinical environments requiring secure airway access and reliable ventilation support. Its dual oral and nasal compatibility provides clinicians with flexibility depending on procedural requirements.

  • Pediatric airway management
  • Operating rooms and surgical procedures
  • Emergency department airway stabilization
  • Intensive care unit mechanical ventilation
  • Anesthesia delivery and respiratory support
  • Hospital respiratory therapy departments

Usage Guidelines

Prior to use, healthcare professionals should verify tube size suitability based on the patient's airway anatomy and clinical indication. The tube should be inserted following standard intubation protocols using appropriate visualization tools such as laryngoscopes or fiberoptic devices.

Once positioned, the clinician should confirm proper placement through auscultation, capnography, and chest movement observation. The preformed shape assists in maintaining tube stability during the procedure and throughout ventilation management.

Certifications and Safety Standards

The Smiths Medical endotracheal tube is manufactured under strict medical device quality standards to ensure consistent performance in critical care environments. Production processes follow internationally recognized quality management systems used for respiratory care products.

  • Manufactured in compliance with global medical device quality standards
  • Sterile and single-use design for infection control
  • Biocompatible medical-grade PVC materials
  • Quality controlled manufacturing processes

Comparison with Competitors

Compared with standard straight endotracheal tubes, the Smiths Medical preformed design offers improved tube stability during long procedures. The Murphy eye configuration adds an extra safety layer by allowing airflow even if the distal opening becomes partially blocked.

Healthcare providers often prefer this model due to its balanced flexibility and structural integrity. Many competing tubes lack the consistent preformed contour that helps reduce tube displacement during patient movement or surgical manipulation.

Typical User Profile and Application Scenarios

This product is designed for professional medical use across a wide range of healthcare environments. Clinicians responsible for airway management rely on preformed tubes like this model to maintain a secure airway during anesthesia and critical care treatment.

  • Anesthesiologists managing surgical airway access
  • Emergency physicians performing rapid airway stabilization
  • Respiratory therapists assisting with ventilation support
  • Critical care teams monitoring ventilated patients
  • Pediatric specialists performing airway management procedures

Best Practices for Use and Maintenance

Always verify packaging integrity and sterility before opening. The tube should be used immediately after removal from sterile packaging. Proper lubrication may assist with atraumatic insertion, and clinicians should monitor airway pressure and patient ventilation continuously during use.

As a single-use device, the tube must be discarded after the procedure in accordance with medical waste protocols. Reuse or reprocessing is not recommended.

Regulatory and Safety Information

This endotracheal tube is intended for use by trained healthcare professionals experienced in airway management. Incorrect placement or misuse can result in airway complications, so strict adherence to clinical protocols is essential.

The device is sterile, latex free, and designed for single patient use only. Healthcare providers should follow institutional guidelines and respiratory care standards when using airway management devices.

How to Order

The Smiths Medical 100/127/055 Endotracheal Tube Oral/Nasal Uncuffed Murphy Preformed PVC 5.5mm ID is available for purchase through CIA Medical. Each case contains 10 sterile tubes ready for clinical use.

To place an order or speak with a product specialist, contact CIA Medical at (312) 275-5850.

Related Products