(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 100/816/090 - TUBE TRACHEOSTOMY SIZE 9MM UNCUFFED 81MM PVC CONTOURED NECK FLANGE INNER CANNULA X 2 OBTURATOR TRACH HOLDER CLEANING BRUSH PORTEX RADIOPAQUE STERILE

Smiths Medical # 100/816/090 - TUBE TRACHEOSTOMY SIZE 9MM UNCUFFED 81MM PVC CONTOURED NECK FLANGE INNER CANNULA X 2 OBTURATOR TRACH HOLDER CLEANING BRUSH PORTEX RADIOPAQUE STERILE
Part Number Smiths Medical 100/816/090
SKU Number CIA1073840
Sell Unit EACH
Ships Within Special Order
List Price $58.11
Enter a valid quantity
Product Description

Smiths Medical 100/816/090 - TUBE TRACHEOSTOMY SIZE 9MM UNCUFFED 81MM PVC CONTOURED NECK FLANGE INNER CANNULA X 2 OBTURATOR TRACH HOLDER CLEANING BRUSH PORTEX RADIOPAQUE STERILE

The Smiths Medical 100/816/090 tracheostomy tube is a high-quality, sterile airway management solution designed for reliable performance and patient comfort. Manufactured from medical-grade PVC, this 9mm uncuffed tracheostomy tube features a contoured neck flange that supports secure positioning while minimizing pressure on the stoma site. The comprehensive kit includes dual inner cannulas, an obturator for smooth insertion, a tracheostomy holder for stabilization, and a cleaning brush to support ongoing hygiene and maintenance. Its radiopaque construction enhances visibility during imaging, making it suitable for both routine and critical care applications.

Key Benefits

This tracheostomy tube offers dependable airway access with an uncuffed design that promotes natural airflow and reduces tracheal pressure. The contoured neck flange improves patient comfort and fit, while the inclusion of two inner cannulas allows for easy replacement and reduced downtime during cleaning. The radiopaque material supports accurate placement verification, and the complete accessory kit ensures clinicians have everything required for efficient insertion and maintenance.

Compatibility and Applications

Designed for use in hospital, surgical, and long-term care settings, this tracheostomy tube is suitable for adult patients requiring airway management without cuff inflation. It is compatible with standard tracheostomy care protocols and integrates seamlessly with suctioning systems and respiratory support equipment. Common applications include post-operative airway support, chronic respiratory conditions, and extended ventilation management where an uncuffed solution is preferred.

Usage Guidelines

Insertion should be performed by trained healthcare professionals following established clinical protocols. The obturator facilitates smooth placement, after which it should be removed and replaced with the inner cannula. Regular inspection and cleaning of the inner cannula are essential to maintain airflow and prevent blockage. The included tracheostomy holder should be properly secured to ensure stability without causing discomfort.

Certifications and Safety Standards

This product is manufactured in accordance with stringent medical device quality standards and is supplied sterile to minimize infection risk. The materials used are biocompatible and suitable for prolonged contact with airway tissues. The radiopaque feature complies with imaging requirements, allowing safe and accurate clinical assessment.

Comparison with Competitors

Compared to standard tracheostomy tubes, this Smiths Medical model stands out with its comprehensive accessory kit and dual inner cannula system, reducing the need for additional purchases. The contoured neck flange offers improved ergonomic support, while the radiopaque PVC construction provides enhanced clinical visibility not always available in basic alternatives.

Typical User Profile and Application Scenarios

This product is ideal for hospitals, intensive care units, respiratory therapy departments, and long-term care facilities. It is commonly used by respiratory therapists, surgeons, and nursing staff managing patients with compromised airways. It is particularly suitable for patients requiring stable, long-term airway access without the need for cuffed pressure.

Best Practices for Use and Maintenance

Maintain strict aseptic technique during insertion and handling. Clean or replace the inner cannula regularly to prevent secretion buildup. Inspect the tube and accessories for signs of wear or blockage, and ensure the tracheostomy holder remains properly adjusted. Routine monitoring of the patients airway condition is essential to ensure optimal performance and safety.

Regulatory and Safety Information

This tracheostomy tube is intended for single-patient use and should not be reused or resterilized. Proper disposal should follow medical waste guidelines. Clinicians should adhere to institutional protocols and manufacturer instructions to ensure safe and effective use.

How to Order

Select the Smiths Medical 100/816/090 TUBE TRACHEOSTOMY SIZE 9MM UNCUFFED 81MM PVC CONTOURED NECK FLANGE INNER CANNULA X 2 OBTURATOR TRACH HOLDER CLEANING BRUSH PORTEX RADIOPAQUE STERILE, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products