(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 101/815/075 - Tracheostomy Tube, 7.5, Cuffed, with Wedge, Non-Fenestrated, PVC

Tracheostomy Tube, 7.5, Cuffed, with Wedge, Non-Fenestrated, PVC
Part Number Smiths Medical 101/815/075
SKU Number CIA8066875
Sell Unit EACH
Ships Within Special Order
List Price Call for Pricing
Product Description

Smiths Medical 101/815/075 - Tracheostomy Tube, 7.5, Cuffed, with Wedge, Non-Fenestrated, PVC

The Smiths Medical 101/815/075 Tracheostomy Tube is a high-quality airway management device designed to provide reliable and secure ventilation support for patients requiring tracheostomy care. Engineered with a 7.5mm internal diameter, this cuffed, non-fenestrated tube is manufactured from medical-grade PVC, offering an optimal balance of flexibility and structural integrity. The inclusion of a wedge-shaped flange enhances stability and positioning, helping clinicians maintain proper placement while minimizing patient discomfort.

This tracheostomy tube is specifically designed for controlled ventilation scenarios where airway security is critical. The non-fenestrated design ensures a closed ventilation system, reducing the risk of air leaks and supporting effective mechanical ventilation. Its smooth surface finish and anatomical contouring contribute to atraumatic insertion and reduced tissue irritation, making it suitable for both short-term and extended use in clinical environments.

Key Benefits

The cuffed design allows for effective sealing within the trachea, helping to maintain consistent airway pressure and reduce the risk of aspiration. The high-volume, low-pressure cuff is engineered to provide a secure seal while minimizing pressure on the tracheal wall, promoting patient safety during prolonged use.

The non-fenestrated structure ensures uninterrupted airflow directly through the tube, making it ideal for patients requiring precise ventilation control. This design also reduces the risk of complications associated with fenestrations, such as tissue ingrowth or misdirected airflow.

The PVC construction offers durability and flexibility, allowing the tube to conform to patient anatomy while maintaining its shape during use. The wedge-shaped flange enhances fixation and positioning, helping clinicians secure the tube more effectively and reduce the likelihood of displacement.

Smooth edges and a carefully designed distal tip facilitate easier insertion and removal, improving clinician handling and patient comfort throughout the procedure.

Compatibility and Applications

This tracheostomy tube is compatible with standard 15mm connectors, allowing seamless integration with ventilators, breathing circuits, and resuscitation equipment commonly used in hospitals and critical care settings. Its universal compatibility ensures flexibility across a wide range of respiratory support systems.

The product is suitable for use in intensive care units, operating rooms, emergency departments, and long-term care facilities. It is particularly effective in situations requiring controlled ventilation, airway protection, and secretion management.

Common applications include post-surgical airway management, long-term ventilator dependency, neurological conditions affecting breathing, and trauma-related airway compromise. The non-fenestrated design makes it especially appropriate for patients who require a closed ventilation system without airflow diversion.

Usage Guidelines

The tracheostomy tube should be inserted by trained healthcare professionals following established clinical protocols. Proper patient assessment and selection of the appropriate tube size are essential to ensure optimal performance and patient safety.

Before insertion, the cuff should be tested for integrity and inflated to confirm proper function. During placement, care should be taken to minimize trauma to surrounding tissues. Once inserted, the cuff should be inflated to achieve an adequate seal without exceeding recommended pressure levels.

Routine monitoring of cuff pressure is important to prevent complications such as tracheal injury or air leakage. The tube should be regularly checked for proper positioning, patency, and signs of wear or obstruction.

Cleaning and maintenance should follow institutional guidelines, and the device should be replaced as clinically indicated to ensure continued performance and hygiene.

Certifications and Safety Standards

The Smiths Medical tracheostomy tube is manufactured in accordance with internationally recognized medical device standards, ensuring consistent quality, safety, and performance. It complies with applicable ISO standards for airway management devices and is produced under strict quality control processes.

The materials used are biocompatible and suitable for medical applications, reducing the risk of adverse reactions. Each unit undergoes rigorous testing to ensure reliability in critical care environments.

Comparison with Competitors

Compared to alternative tracheostomy tubes in the same category, this model stands out for its balanced combination of flexibility and durability. The high-volume, low-pressure cuff design provides a more patient-friendly sealing mechanism compared to standard cuffs that may exert higher localized pressure.

The wedge-shaped flange offers enhanced stability compared to flat flange designs commonly found in competing products. This feature contributes to improved tube positioning and reduced movement during patient care.

Additionally, the consistent quality of PVC construction ensures predictable performance, whereas some lower-cost alternatives may exhibit variability in material strength and flexibility. The non-fenestrated design also reduces potential complications associated with fenestrated tubes, making it a reliable choice for controlled ventilation scenarios.

Typical User Profile and Application Scenarios

This product is widely used by respiratory therapists, anesthesiologists, critical care physicians, and nursing staff involved in airway management. It is suitable for adult patients requiring tracheostomy support in both acute and long-term care settings.

Typical scenarios include patients recovering from major surgery, individuals with chronic respiratory failure, and those requiring prolonged mechanical ventilation. It is also used in emergency situations where rapid airway access is necessary.

Healthcare facilities such as hospitals, rehabilitation centers, and specialized respiratory care units benefit from the reliability and ease of use offered by this tracheostomy tube.

Best Practices for Use and Maintenance

To ensure optimal performance, the tracheostomy tube should be handled using aseptic techniques during insertion and maintenance. Regular inspection of the tube and cuff is essential to identify any signs of damage or wear.

Cuff pressure should be monitored using appropriate devices to maintain it within recommended limits. Overinflation should be avoided to prevent tracheal injury, while underinflation may compromise the airway seal.

The tube should be secured properly using appropriate fixation methods to prevent accidental displacement. Routine suctioning and airway clearance should be performed as needed to maintain patency.

Replacement intervals should be determined based on clinical guidelines and patient condition, ensuring that the device remains safe and effective throughout its use.

Regulatory and Safety Information

This tracheostomy tube is intended for use by qualified healthcare professionals in controlled medical environments. It is important to follow all manufacturer instructions and institutional protocols when using this device.

Patients should be monitored continuously for signs of respiratory distress, tube displacement, or complications related to cuff pressure. Any adverse events or device malfunctions should be reported according to regulatory requirements.

The product is supplied sterile and is intended for single-patient use unless otherwise specified. Proper disposal should be carried out in accordance with local regulations for medical waste.

How to Order

Select the Smiths Medical 101/815/075 Tracheostomy Tube, 7.5, Cuffed, with Wedge, Non-Fenestrated, PVC, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products