Tracheostomy Tube, 10.0, Cuffed, with Wedge, Non-Fenestrated, PVC
Part Number Smiths Medical 101/815/100
SKU Number CIA8066864
Sell Unit EACH
Ships Within Special Order
List Price $82.11
Enter a valid quantity
Product Description

Smiths Medical 101/815/100 - Tracheostomy Tube, 10.0, Cuffed, with Wedge, Non-Fenestrated, PVC

The Smiths Medical 101/815/100 Tracheostomy Tube is designed to support safe and effective airway management in clinical settings. This size 10.0 cuffed, non-fenestrated tracheostomy tube is manufactured from high-quality medical-grade PVC to provide both durability and patient comfort during short-term or extended use. The integrated wedge design enhances secure placement and stability, helping to minimize movement within the trachea.

This device is specifically engineered for controlled ventilation and airway protection, making it suitable for use in critical care, emergency medicine, and surgical recovery environments. The non-fenestrated construction ensures a closed airway system, reducing the risk of aspiration and maintaining consistent airflow during mechanical ventilation.

Key Benefits

The cuffed design allows for effective sealing within the trachea, supporting positive pressure ventilation and reducing the risk of air leakage. The high-volume, low-pressure cuff helps distribute pressure evenly, minimizing the risk of tracheal injury.

The non-fenestrated structure provides a reliable airway without openings, making it ideal for patients who require full ventilation support or protection against aspiration.

The medical-grade PVC material offers flexibility and strength, adapting to anatomical contours while maintaining structural integrity over time.

The wedge feature enhances tube stability and positioning, reducing the likelihood of displacement during patient movement or clinical procedures.

Smooth inner and outer surfaces are designed to reduce secretion buildup and facilitate easier suctioning and maintenance.

Compatibility and Applications

This tracheostomy tube is compatible with standard 15 mm connectors, allowing seamless integration with ventilators, anesthesia circuits, and resuscitation equipment. It is suitable for use across a wide range of clinical environments, including intensive care units, operating rooms, emergency departments, and long-term care facilities.

The product is commonly used for adult patients requiring airway management, mechanical ventilation, or airway protection following surgery or trauma. It is also suitable for patients with compromised respiratory function who need a secure and stable airway.

Usage Guidelines

The tracheostomy tube should be inserted by trained healthcare professionals following established clinical protocols. Proper sizing must be confirmed prior to insertion to ensure optimal fit and performance.

Before use, the cuff should be tested for integrity and inflated using appropriate techniques to achieve a secure seal without excessive pressure. Continuous monitoring of cuff pressure is recommended to prevent complications.

The tube should be regularly inspected for signs of blockage, displacement, or wear. Routine suctioning and cleaning should be performed as needed to maintain airway patency.

Replacement schedules should follow institutional guidelines and patient-specific needs to ensure safety and hygiene.

Certifications and Safety Standards

The Smiths Medical tracheostomy tube is manufactured in compliance with internationally recognized medical device standards. It adheres to strict quality control processes to ensure consistency, safety, and performance in clinical use.

The materials used are biocompatible and designed to meet healthcare safety requirements. The product is sterile and intended for single-patient use, reducing the risk of cross-contamination and infection.

Comparison with Competitors

Compared to other tracheostomy tubes in its category, this model stands out for its balanced combination of flexibility and structural support provided by the medical-grade PVC construction. The wedge design offers enhanced stability, which is not always present in standard tracheostomy tubes.

The high-quality cuff design provides reliable sealing with minimal pressure, helping reduce complications often associated with lower-grade alternatives. Additionally, the smooth finish and consistent manufacturing quality contribute to improved patient comfort and ease of use for clinicians.

While some competing products may offer fenestrated options, this non-fenestrated design is preferred in cases where airway protection and controlled ventilation are critical.

Typical User Profile and Application Scenarios

This product is typically used by healthcare professionals such as respiratory therapists, anesthesiologists, critical care nurses, and surgeons. It is suitable for adult patients requiring secure airway access due to respiratory failure, surgical recovery, or long-term ventilation needs.

Common application scenarios include intensive care management, post-operative airway support, emergency airway access, and chronic respiratory care. The device is also used in settings where maintaining a closed airway system is essential to prevent aspiration.

Best Practices for Use and Maintenance

To ensure optimal performance, clinicians should follow best practices including regular monitoring of cuff pressure, proper securing of the tube, and routine cleaning of the airway.

Humidification of inspired air is recommended to prevent drying of airway secretions. Suctioning should be performed using sterile techniques to maintain hygiene and reduce infection risk.

The tube should be checked frequently for any signs of blockage or displacement. Proper fixation methods should be used to keep the tube securely in place while allowing patient comfort.

Any signs of damage or deterioration should prompt immediate replacement to maintain patient safety.

Regulatory and Safety Information

This tracheostomy tube is intended for use by qualified medical professionals only. It is supplied sterile and should not be used if the packaging is damaged or compromised.

Single-use guidelines must be strictly followed to prevent infection and ensure patient safety. Disposal should be carried out in accordance with local medical waste regulations.

Users should adhere to all institutional protocols and manufacturer recommendations when handling and using the product.

How to Order

Select the Smiths Medical 101/815/100 Tracheostomy Tube, 10.0, Cuffed, with Wedge, Non-Fenestrated, PVC, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products