(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 101/817/090 - Tracheostomy Tube, 9.0, Cuffed, with Wedge and Decan Cap, Fenestrated, PVC

Tracheostomy Tube, 9.0, Cuffed, with Wedge and Decan Cap, Fenestrated, PVC
Part Number Smiths Medical 101/817/090
SKU Number CIA8066883
Sell Unit EACH
Ships Within Special Order
List Price $97.19
Enter a valid quantity
Product Description

Smiths Medical 101/817/090 - Tracheostomy Tube, 9.0, Cuffed, with Wedge and Decan Cap, Fenestrated, PVC

The Smiths Medical 101/817/090 Tracheostomy Tube is a high-quality airway management device designed to support patients requiring long-term or short-term tracheostomy care. Manufactured from medical-grade PVC, this size 9.0 tracheostomy tube features a cuffed design, fenestration, wedge-shaped flange, and an included decannulation cap, offering both flexibility and clinical control.

This tracheostomy tube is engineered to maintain airway patency while allowing for controlled ventilation and the potential for speech when clinically appropriate. The fenestrated design enables airflow through the vocal cords when the cuff is deflated and the inner cannula is removed, supporting improved patient communication and comfort during recovery phases.

The integrated cuff ensures an effective seal within the trachea, making it suitable for patients requiring positive pressure ventilation or protection against aspiration. The wedge-shaped neck flange is anatomically contoured to improve fit and reduce pressure points, enhancing patient comfort during extended use.

Designed for use in hospitals, surgical centers, and long-term care facilities, this tracheostomy tube delivers reliable performance in demanding clinical environments.

Key Benefits

This tracheostomy tube provides a secure and reliable airway with its cuffed design, ensuring effective ventilation support and minimizing the risk of aspiration. The fenestrated structure supports airflow through the upper airway, enabling speech when clinically appropriate and contributing to improved patient quality of life.

The inclusion of a decannulation cap allows clinicians to assess a patients readiness for tube removal by enabling normal breathing through the upper airway. This makes it a practical solution for both active airway management and transitional care.

The PVC construction offers a balance between flexibility and structural integrity, allowing for ease of insertion while maintaining the shape necessary for consistent airflow. The smooth surface minimizes tissue irritation, supporting patient comfort during prolonged use.

The anatomically designed wedge flange improves stability and positioning, reducing movement and potential discomfort around the stoma site.

Compatibility and Applications

The Smiths Medical 101/817/090 tracheostomy tube is compatible with standard 15 mm connectors, making it suitable for use with a wide range of ventilators, anesthesia circuits, and respiratory support devices. This compatibility ensures seamless integration into existing clinical setups without the need for specialized adapters.

It is commonly used in intensive care units, operating rooms, and long-term care settings for patients requiring airway access due to respiratory failure, neurological conditions, trauma, or post-surgical recovery.

The fenestrated design makes it particularly suitable for patients in the weaning phase of mechanical ventilation or those undergoing speech rehabilitation. It supports both ventilated and spontaneously breathing patients, depending on clinical requirements.

Usage Guidelines

The tracheostomy tube should be inserted and managed by trained healthcare professionals following established clinical protocols. Proper sizing must be confirmed prior to insertion to ensure optimal fit and minimize complications.

Before use, the cuff should be tested for integrity and inflated to the appropriate pressure once positioned within the trachea. Overinflation should be avoided to prevent tracheal injury.

For patients transitioning toward decannulation, the fenestration and decannulation cap can be utilized under supervision to assess airway function and readiness. Regular monitoring of the stoma site and airway patency is essential to ensure patient safety.

Routine cleaning or replacement of the inner cannula, if applicable, should be performed according to clinical guidelines to maintain hygiene and airflow efficiency.

Certifications and Safety Standards

This tracheostomy tube is manufactured in compliance with recognized international medical device standards, ensuring safety, reliability, and consistent performance. It meets regulatory requirements for use in professional healthcare settings and is produced under strict quality control systems.

The materials used are biocompatible and designed to minimize adverse reactions, supporting safe use in sensitive airway environments. Each unit is packaged to maintain sterility until point of use.

Comparison with Competitors

Compared to standard non-fenestrated tracheostomy tubes, this model offers enhanced versatility by supporting both ventilation and speech capabilities. The fenestrated design provides a significant advantage for patient rehabilitation and comfort.

In contrast to silicone-only tubes, the PVC construction provides a balance of flexibility and durability, making it easier to handle during insertion while maintaining structural integrity during use.

The inclusion of both a wedge flange and decannulation cap distinguishes this product from basic models, offering additional clinical functionality without requiring separate accessories. This integrated approach improves workflow efficiency and reduces the need for additional components.

Typical User Profile and Application Scenarios

This tracheostomy tube is ideal for use by respiratory therapists, anesthesiologists, critical care physicians, and nursing staff involved in airway management. It is commonly used in patients requiring prolonged ventilation, airway protection, or post-operative respiratory support.

It is also suitable for patients in rehabilitation phases where speech restoration and gradual weaning from mechanical ventilation are priorities. Long-term care facilities benefit from its durability and patient comfort features, making it a reliable choice for extended use.

The product is particularly useful in clinical scenarios where flexibility in airway management is required, such as transitioning from full ventilatory support to spontaneous breathing.

Best Practices for Use and Maintenance

To ensure optimal performance, the tracheostomy tube should be regularly inspected for signs of wear, blockage, or damage. Proper cuff pressure monitoring is essential to maintain an effective seal without causing tracheal injury.

The stoma site should be kept clean and dry, with routine care provided to prevent infection or irritation. Healthcare providers should follow institutional protocols for cleaning, suctioning, and replacing components as needed.

When using the fenestration feature, clinicians should ensure that the patient is appropriately assessed and monitored to prevent complications such as aspiration or inadequate ventilation.

Storage should be in a clean, dry environment, and the product should remain in its original packaging until use to maintain sterility.

Regulatory and Safety Information

This tracheostomy tube is intended for use by trained medical professionals in controlled healthcare environments. It is supplied sterile and designed for single-patient use unless otherwise specified by institutional guidelines.

Users must follow all applicable clinical protocols and manufacturer recommendations to ensure safe and effective use. Any signs of device malfunction or patient discomfort should be addressed immediately, and the device should be replaced if necessary.

Proper disposal should be carried out in accordance with local regulations for medical waste to ensure environmental and public safety.

How to Order

Select the Smiths Medical 101/817/090 Tracheostomy Tube, 9.0, Cuffed, with Wedge and Decan Cap, Fenestrated, PVC, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products