Smiths Medical 101/856/075 - Replacement Inner Cannula, 7.5, Non-Fenestrated, 20/bx

Replacement Inner Cannula, 7.5, Non-Fenestrated, 20/bx
Part Number Smiths Medical 101/856/075
SKU Number CIA8066848
Sell Unit BOX
Ships Within Special Order
List Price $135.76
Enter a valid quantity
Product Description

Smiths Medical 101/856/075 - Replacement Inner Cannula, 7.5, Non-Fenestrated, 20/bx

The Smiths Medical 101/856/075 Replacement Inner Cannula is designed to support safe and efficient airway management in patients with tracheostomy tubes. Engineered for size 7.5 tracheostomy systems, this non-fenestrated inner cannula provides a secure and reliable airway pathway while maintaining optimal hygiene and ease of maintenance. Supplied in a convenient box of 20 units, it allows healthcare providers to maintain consistent replacement schedules and reduce the risk of contamination.

Manufactured using high-quality medical-grade materials, this inner cannula is designed to ensure patient comfort, durability, and compatibility with corresponding tracheostomy tubes. Its non-fenestrated design ensures uninterrupted airflow and is particularly suitable for patients who do not require speech facilitation or airflow diversion through the upper airway.

Key Benefits

This replacement inner cannula is designed for quick and efficient changes, helping clinicians maintain airway patency with minimal disruption to the patient. The smooth surface and precision engineering reduce the buildup of secretions, supporting better hygiene and lowering the risk of infection. Its standardized sizing ensures a secure fit within compatible tracheostomy tubes, minimizing the chance of displacement or leakage.

The non-fenestrated design provides a consistent airflow pathway, making it ideal for patients requiring stable ventilation support. The disposable format supports infection control protocols, allowing healthcare facilities to maintain high standards of patient safety while reducing the burden of cleaning and sterilization.

Compatibility and Applications

The Smiths Medical 101/856/075 Replacement Inner Cannula is specifically designed for use with compatible size 7.5 tracheostomy tubes from the same manufacturer. It is widely used in hospitals, intensive care units, long-term care facilities, and home care settings where tracheostomy management is required.

This product is suitable for adult patients who require a non-fenestrated airway solution. It is commonly used in situations where mechanical ventilation support is necessary or where airflow diversion is not clinically indicated. Its compatibility with standard tracheostomy systems ensures seamless integration into existing care protocols.

Usage Guidelines

Before use, clinicians should verify compatibility with the existing tracheostomy tube and confirm the correct size. The inner cannula should be inserted gently into the outer cannula until securely locked in place. Proper hand hygiene and aseptic technique must be followed during insertion and removal to prevent contamination.

Routine replacement is recommended based on clinical protocols or when visible buildup of secretions occurs. Patients and caregivers in home care settings should receive proper training on safe handling and replacement procedures. Used cannulas should be disposed of according to medical waste guidelines.

Certifications and Safety Standards

This product is manufactured in accordance with recognized medical device standards to ensure safety, reliability, and performance. It meets stringent quality control requirements and is produced in facilities that follow international manufacturing practices. Materials used are biocompatible and suitable for prolonged contact with airway tissues.

The product packaging is designed to maintain sterility and integrity until use, supporting compliance with infection control standards in clinical environments.

Comparison with Competitors

Compared to alternative inner cannulas on the market, the Smiths Medical 101/856/075 stands out for its consistent fit and reliable performance within compatible systems. Its design minimizes airflow resistance while maintaining structural integrity during use. Many competing products may require additional adjustments or may not provide the same level of compatibility with branded tracheostomy tubes.

The disposable nature of this cannula also provides an advantage over reusable options by reducing cleaning time and lowering the risk of cross-contamination. Healthcare providers benefit from predictable performance and ease of use, making it a preferred choice in high-demand clinical settings.

Typical User Profile and Application Scenarios

This product is commonly used by respiratory therapists, nurses, and physicians responsible for airway management. It is suitable for patients in critical care units who require stable ventilation support, as well as for individuals in rehabilitation or long-term care settings managing chronic respiratory conditions.

Home care patients with tracheostomies also benefit from this product due to its straightforward replacement process and hygienic design. Caregivers can manage routine maintenance effectively, ensuring patient comfort and reducing the likelihood of complications.

Best Practices for Use and Maintenance

To ensure optimal performance, the inner cannula should be inspected regularly for signs of blockage or wear. Replacement should be carried out according to established clinical schedules or as needed based on patient condition. Maintaining a clean and sterile environment during handling is essential to prevent infections.

Healthcare providers should educate patients and caregivers on proper insertion techniques and disposal methods. Keeping an adequate supply on hand ensures timely replacement and uninterrupted airway management.

Regulatory and Safety Information

This product is intended for use by trained healthcare professionals or individuals under medical supervision. It should only be used with compatible tracheostomy tubes and in accordance with manufacturer guidelines. Improper use may lead to airway obstruction or patient discomfort.

All used cannulas must be treated as medical waste and disposed of in compliance with local regulations. Regular monitoring of the patients airway condition is essential to ensure continued safety and effectiveness.

How to Order

Select the Smiths Medical 101/856/075 Replacement Inner Cannula, 7.5, Non-Fenestrated, 20/bx, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.