(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 101/875/060 - Suctionaid Tube, 6.0, Cuffed, with Wedge, Non-Fenestrated

Suctionaid Tube, 6.0, Cuffed, with Wedge, Non-Fenestrated
Part Number Smiths Medical 101/875/060
SKU Number CIA8066857
Sell Unit EACH
Ships Within Special Order
List Price $108.29
Enter a valid quantity
Product Description

Smiths Medical 101/875/060 - Suctionaid Tube, 6.0, Cuffed, with Wedge, Non-Fenestrated

The Smiths Medical 101/875/060 Suctionaid Tracheostomy Tube is designed to support efficient airway management while enabling subglottic suctioning to reduce the risk of ventilator-associated complications. This 6.0 mm cuffed, non-fenestrated tracheostomy tube integrates a Suctionaid feature that allows for continuous or intermittent removal of secretions from above the cuff, helping maintain airway hygiene and patient safety in critical care environments.

Constructed from high-quality medical-grade PVC, the tube offers flexibility combined with structural integrity, ensuring a secure fit within the trachea while minimizing patient discomfort. The included wedge design enhances positioning stability and supports secure placement, particularly in long-term airway management scenarios. Its non-fenestrated configuration is ideal for patients requiring controlled ventilation without airflow leakage through fenestrations.

This product is engineered for reliability in intensive care units, surgical settings, and long-term care facilities, where maintaining airway patency and reducing aspiration risk are critical priorities.

Key Benefits

The integrated Suctionaid system allows clinicians to efficiently remove subglottic secretions, reducing the likelihood of aspiration and associated respiratory infections. This feature supports improved patient outcomes, especially for those on prolonged mechanical ventilation.

The cuffed design provides an effective seal within the trachea, enabling controlled ventilation and minimizing air leakage. This is essential for maintaining consistent airway pressure and optimizing respiratory support.

The wedge-shaped flange contributes to enhanced tube stability and patient comfort, reducing movement and the risk of accidental displacement during use.

Its non-fenestrated construction ensures uninterrupted airflow through the tube, making it suitable for patients who require precise ventilation control without additional airway openings.

The use of soft yet durable PVC material enhances patient tolerance while ensuring long-lasting performance in demanding clinical environments.

Compatibility and Applications

This tracheostomy tube is compatible with standard 15 mm connectors, allowing seamless integration with most ventilators, breathing circuits, and suction systems commonly used in healthcare settings.

It is widely used in intensive care units, emergency departments, operating rooms, and long-term care facilities for patients requiring airway access and mechanical ventilation support.

The Suctionaid functionality makes it particularly suitable for patients at higher risk of secretion buildup or aspiration, including those undergoing prolonged ventilation or recovering from major respiratory procedures.

It is also appropriate for post-surgical airway management and for patients with compromised airway clearance mechanisms.

Usage Guidelines

Prior to insertion, clinicians should verify the correct tube size and ensure all components are intact and functioning properly. The cuff should be tested for integrity by inflating and deflating before placement.

During insertion, standard sterile techniques should be followed to minimize infection risk. The tube should be positioned carefully within the trachea and secured using appropriate fixation methods.

The cuff should be inflated to the recommended pressure to create an effective seal without causing tracheal injury. Regular monitoring of cuff pressure is essential to maintain patient safety.

The Suctionaid port should be connected to a compatible suction system for removal of subglottic secretions. Suctioning should be performed according to clinical protocols to avoid mucosal damage.

Routine assessment of tube placement, airway patency, and patient comfort should be conducted throughout use.

Certifications and Safety Standards

This product is manufactured in accordance with internationally recognized medical device standards, ensuring high levels of safety, quality, and performance.

It complies with applicable ISO standards for airway management devices and is produced in facilities adhering to strict quality control processes.

The materials used are biocompatible and suitable for medical applications, minimizing the risk of adverse reactions during patient use.

Each unit undergoes rigorous testing to ensure consistent performance and reliability in clinical environments.

Comparison with Competitors

Compared to standard tracheostomy tubes without subglottic suction capabilities, the Smiths Medical Suctionaid tube provides a significant advantage in managing secretions and reducing the risk of ventilator-associated complications.

While many competing products offer basic airway support, this model integrates advanced suction functionality without compromising structural integrity or patient comfort.

The wedge flange design offers improved stability compared to flat flange alternatives, reducing the likelihood of displacement and enhancing overall usability.

Its high-quality PVC construction ensures durability and flexibility, outperforming lower-grade materials that may become rigid or uncomfortable over time.

Typical User Profile and Application Scenarios

This product is ideal for healthcare professionals working in critical care settings who require reliable airway management solutions for patients with complex respiratory needs.

It is commonly used by respiratory therapists, anesthesiologists, and intensive care clinicians managing patients on mechanical ventilation.

Typical scenarios include long-term ventilation support, post-operative airway management, and care for patients with compromised airway clearance.

It is also suitable for use in specialized care units where infection prevention and secretion management are critical components of patient care.

Best Practices for Use and Maintenance

Regular monitoring of cuff pressure is essential to prevent tracheal injury and ensure an effective seal. Clinicians should use appropriate pressure monitoring devices to maintain optimal levels.

The Suctionaid port should be checked frequently to ensure proper function and prevent blockage. Consistent suctioning protocols should be followed to maintain airway cleanliness.

The tube should be inspected regularly for signs of wear, damage, or displacement. Any compromised components should be replaced immediately.

Proper hygiene practices, including regular cleaning of external components and adherence to infection control protocols, are critical for maintaining patient safety.

Secure fixation should be maintained at all times to prevent accidental decannulation or movement.

Regulatory and Safety Information

This tracheostomy tube is intended for use by trained healthcare professionals in controlled clinical environments. It should only be used in accordance with established medical guidelines and institutional protocols.

Single-use guidelines should be followed where applicable, and the product should not be reused unless explicitly stated by the manufacturer.

Proper disposal procedures must be followed after use to comply with medical waste regulations and prevent contamination.

Clinicians should be familiar with emergency airway management procedures in case of complications during use.

How to Order

Select the Smiths Medical 101/875/060 Suctionaid Tube, 6.0, Cuffed, with Wedge, Non-Fenestrated , and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products