(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 101/875/080 - Suctionaid Tube, 8.0, Cuffed, with Wedge, Non-Fenestrated

Suctionaid Tube, 8.0, Cuffed, with Wedge, Non-Fenestrated
Part Number Smiths Medical 101/875/080
SKU Number CIA8066860
Sell Unit EACH
Ships Within Special Order
List Price $108.29
Enter a valid quantity
Product Description

Smiths Medical 101/875/080 - Suctionaid Tube, 8.0, Cuffed, with Wedge, Non-Fenestrated

The Smiths Medical 101/875/075 Suctionaid Tube is a high-performance tracheostomy solution designed to support effective airway management in clinical and critical care settings. Featuring a 7.5 mm internal diameter, this cuffed, non-fenestrated tube is engineered to provide a secure airway while enabling efficient subglottic suctioning to help reduce the risk of ventilator-associated complications. The integrated suctionaid design allows for continuous or intermittent removal of secretions that accumulate above the cuff, enhancing patient safety and respiratory hygiene.

This tube is constructed from medical-grade materials that balance flexibility and structural integrity, ensuring patient comfort without compromising performance. The included wedge design supports stable placement and positioning, making it suitable for long-term airway management. Its non-fenestrated configuration ensures a closed airway system, which is essential for patients requiring controlled ventilation.

Key Benefits

The Suctionaid Tube is specifically developed to address key challenges in airway management. Its subglottic suction capability helps minimize secretion buildup, reducing the risk of aspiration and infection. The cuffed design provides an effective seal within the trachea, ensuring optimal ventilation efficiency and preventing air leakage.

The wedge feature enhances stability, reducing movement and potential irritation within the trachea. The smooth surface and carefully engineered contours improve patient comfort, particularly during extended use. Additionally, the durable construction ensures consistent performance in demanding clinical environments, making it a reliable choice for healthcare providers.

Compatibility and Applications

This tracheostomy tube is compatible with standard ventilator systems and suction equipment used in hospitals, intensive care units, and long-term care facilities. It is designed for use in patients who require mechanical ventilation or airway protection, particularly those at risk of secretion accumulation above the cuff.

Common applications include critical care ventilation, post-surgical airway management, and long-term respiratory support. The non-fenestrated design makes it especially suitable for patients who need a sealed airway to maintain precise ventilation control.

Usage Guidelines

The tube should be inserted and managed by trained healthcare professionals following established clinical protocols. Proper sizing should be confirmed prior to insertion to ensure optimal fit and function. The cuff should be inflated to the recommended pressure to achieve an effective seal without causing tracheal damage.

Regular monitoring of cuff pressure and suction function is essential to maintain performance and patient safety. Subglottic suctioning should be performed according to clinical guidelines, either continuously or intermittently, depending on patient needs. Routine inspection of the tube for signs of wear or blockage is also recommended.

Certifications and Safety Standards

The Smiths Medical Suctionaid Tube is manufactured in compliance with international medical device standards to ensure safety, reliability, and performance. It adheres to strict quality control processes and is designed to meet regulatory requirements for use in professional healthcare environments.

The materials used are biocompatible and suitable for prolonged contact with airway tissues, minimizing the risk of adverse reactions. Each unit is produced under controlled conditions to ensure consistency and sterility where applicable.

Comparison with Competitors

Compared to standard tracheostomy tubes, the Suctionaid Tube offers a significant advantage with its integrated subglottic suction feature. This functionality is not commonly available in basic models and provides an added layer of protection against complications associated with secretion buildup.

While some competing products may offer similar cuffed designs, the combination of suction capability, wedge stability, and high-quality construction distinguishes this product in terms of both performance and patient outcomes. Its reliability in maintaining airway integrity and reducing infection risk makes it a preferred choice in advanced care settings.

Typical User Profile and Application Scenarios

This product is ideal for use by healthcare professionals in intensive care units, respiratory therapy departments, and long-term care facilities. It is particularly beneficial for patients requiring prolonged ventilation support or those at increased risk of aspiration.

Typical scenarios include patients recovering from major surgery, individuals with compromised respiratory function, and those requiring ongoing airway management due to chronic conditions. The tubes design supports both acute and extended care applications, providing flexibility across different treatment plans.

Best Practices for Use and Maintenance

To ensure optimal performance, the tube should be handled with care during insertion and removal. Regular cleaning of external components and proper maintenance of suction equipment are essential. Healthcare providers should follow infection control protocols, including routine replacement schedules and adherence to sterile techniques.

Monitoring patient comfort and airway condition is also important, as early detection of issues can prevent complications. Maintaining appropriate cuff pressure and ensuring consistent suction functionality will contribute to better patient outcomes and device longevity.

Regulatory and Safety Information

This device is intended for use by trained medical professionals in controlled healthcare environments. It should be used in accordance with all applicable clinical guidelines and institutional policies. Proper training in airway management and suction techniques is required to ensure safe and effective use.

Any signs of device malfunction or patient discomfort should be addressed immediately. The product should only be used for its intended purpose and in compliance with all relevant safety standards and regulations.

How to Order

Select the Smiths Medical 101/875/080 Suctionaid Tube, 8.0, Cuffed, with Wedge, Non-Fenestrated, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products