-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
Smiths Medical 103005 - Stylet Blue Line Intubation f/ 5-7mm Tube 10/Ca
The Smiths Medical 103005 Blue Line Intubation Stylet is designed to support precise and controlled endotracheal tube placement in airway management procedures. Engineered for compatibility with 57 mm internal diameter endotracheal tubes, this stylet provides clinicians with the flexibility and stability required to guide tubes effectively during intubation. Its smooth, coated surface minimizes friction, allowing for easy insertion and removal while helping to reduce the risk of trauma to the airway.
Manufactured with clinical reliability in mind, the Blue Line stylet offers a balanced combination of malleability and rigidity, enabling healthcare professionals to shape it according to procedural needs without compromising structural integrity. Supplied in convenient packs of 10, it is well-suited for hospitals, emergency departments, surgical centers, and critical care environments.
Key Benefits
The stylet provides optimal shape retention, allowing clinicians to pre-form the desired curvature for efficient tube navigation. Its smooth outer coating enhances patient safety by reducing friction during insertion and withdrawal. The device supports improved control during difficult intubations, helping to increase first-pass success rates. Its compatibility with commonly used tube sizes ensures versatility across a wide range of patient scenarios. Additionally, the single-use design promotes hygiene and reduces the risk of cross-contamination.
Compatibility and Applications
This intubation stylet is specifically designed for use with endotracheal tubes ranging from 5 mm to 7 mm in internal diameter. It is suitable for a variety of clinical settings, including operating rooms, emergency care units, intensive care units, and pre-hospital emergency response. The stylet supports both routine and complex airway management procedures, including rapid sequence intubation and difficult airway cases.
It is compatible with standard airway management systems and is commonly used alongside laryngoscopes and other intubation tools to facilitate accurate tube placement.
Usage Guidelines
Before use, the stylet should be shaped to match the desired curvature required for the procedure. It should be inserted carefully into the endotracheal tube, ensuring that the distal tip does not extend beyond the tube to prevent airway injury. During intubation, clinicians should maintain control of both the stylet and the tube to guide placement effectively.
After successful tube placement, the stylet should be gently withdrawn while stabilizing the tube. As a single-use device, it should be disposed of immediately after use in accordance with clinical waste protocols.
Certifications and Safety Standards
The Smiths Medical Blue Line Intubation Stylet is manufactured in compliance with recognized medical device quality standards. It is produced under strict quality control processes to ensure consistency, reliability, and patient safety. The device meets applicable regulatory requirements for use in professional healthcare environments.
Comparison with Competitors
Compared to generic intubation stylets, the Smiths Medical Blue Line model offers superior coating quality that reduces friction and enhances ease of use. Its consistent malleability allows for better customization of shape without compromising strength. While some alternatives may lose form during procedures, this stylet maintains its structure, providing greater control and reliability. The trusted Smiths Medical manufacturing standards further distinguish it from lower-quality options in the market.
Typical User Profile and Application Scenarios
This product is commonly used by anesthesiologists, emergency physicians, respiratory therapists, and critical care specialists who require dependable tools for airway management. It is ideal for use in surgical procedures requiring intubation, emergency airway interventions, and intensive care settings where rapid and accurate tube placement is essential.
It is also suitable for paramedics and first responders managing airway emergencies in pre-hospital environments.
Best Practices for Use and Maintenance
Clinicians should always inspect the stylet before use to ensure it is free from defects or damage. Proper shaping techniques should be applied to avoid sharp bends that could compromise performance. During use, care should be taken to prevent the stylet tip from extending beyond the endotracheal tube.
As a single-use device, no maintenance is required. Proper disposal after each use is essential to maintain infection control standards and ensure patient safety.
Regulatory and Safety Information
This device is intended for use by trained healthcare professionals only. It should be used in accordance with established clinical guidelines for airway management. Users must follow all applicable institutional protocols and safety procedures. Any adverse events or product concerns should be reported according to regulatory requirements.
How to Order
Select the Smiths Medical 103005 Stylet Blue Line Intubation f/ 5-7mm Tube 10/Ca,and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.