-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
Smiths Medical 103006 - Stylette Intubation Blue Line 7.5-10M 10/CS
The Smiths Medical 103006 Blue Line Intubation Stylet is a precision-engineered airway accessory designed to support accurate and efficient endotracheal tube placement. Built for flexibility and control, this stylet provides clinicians with enhanced maneuverability during intubation procedures, especially in challenging airway conditions. Covering a size range of 7.5 to 10 mm, it is suitable for a broad spectrum of adult airway management scenarios.
Manufactured with a smooth, plastic-coated surface, the stylet reduces friction and minimizes trauma during insertion and removal. Its malleable core allows clinicians to shape it as needed while maintaining sufficient rigidity for consistent guidance. Packaged in a convenient 10 units per case, it is ideal for hospitals, emergency departments, surgical centers, and critical care units requiring reliable airway management tools.
Key Benefits
The Blue Line stylet delivers a balance of flexibility and stability, enabling precise shaping for improved intubation success rates. Its smooth coating reduces the risk of airway irritation and ensures easy removal from the endotracheal tube after placement. The wide compatibility with standard tube sizes enhances its versatility across multiple clinical settings.
The design supports quick adjustments during procedures, allowing clinicians to respond effectively to anatomical variations. Its durable construction ensures consistent performance without compromising patient safety.
Compatibility and Applications
This intubation stylet is compatible with endotracheal tubes ranging from 7.5 mm to 10 mm in internal diameter. It is commonly used in operating rooms, intensive care units, emergency departments, and pre-hospital environments where airway management is critical.
It is particularly useful in cases requiring controlled tube placement, such as difficult airways, trauma situations, or patients with limited neck mobility. The stylet supports both routine and advanced intubation techniques.
Usage Guidelines
Before use, shape the stylet according to the desired curvature while ensuring it remains within the tubes lumen without protruding from the distal end. Insert the stylet into the endotracheal tube carefully, maintaining alignment to prevent damage to the airway.
During intubation, guide the tube gently into position. Once placement is confirmed, withdraw the stylet smoothly to avoid dislodging the tube. Dispose of the stylet according to clinical waste protocols after single use.
Certifications and Safety Standards
The Smiths Medical Blue Line Intubation Stylet is manufactured in compliance with recognized medical device standards, ensuring safety, reliability, and consistent quality. It meets stringent regulatory requirements for use in clinical environments and is produced under controlled conditions to support infection control protocols.
Comparison with Competitors
Compared to standard metal stylets, the Blue Line version offers a smoother insertion experience due to its plastic coating, reducing the likelihood of tissue irritation. Its balance of flexibility and firmness provides improved control over tube shaping, which is often lacking in lower-quality alternatives.
Unlike some disposable stylets that may lose shape quickly, this model maintains structural integrity throughout the procedure, giving clinicians greater confidence during critical airway interventions.
Typical User Profile and Application Scenarios
This product is widely used by anesthesiologists, emergency physicians, respiratory therapists, and critical care specialists. It is suitable for both routine surgical intubations and high-pressure emergency situations.
Hospitals, ambulatory surgical centers, and emergency response teams benefit from its reliability, especially when rapid and accurate airway access is essential for patient stabilization.
Best Practices for Use and Maintenance
Always inspect the stylet before use to ensure there are no defects or irregularities. Shape the stylet gently to avoid damaging its internal structure. Avoid over-bending, as this may affect performance.
Use the stylet strictly as a single-use device to maintain infection control standards. Store in a clean, dry environment and follow institutional protocols for handling and disposal.
Regulatory and Safety Information
This device is intended for use by trained healthcare professionals experienced in airway management. Proper technique and adherence to clinical guidelines are essential to ensure patient safety. The product is designed for single use and should not be reprocessed or reused.
Always follow institutional policies and applicable healthcare regulations when using and disposing of medical devices.
How to Order
Select the Smiths Medical 103006 Stylette Intubation Blue Line 7.5-10M 10/CS, and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.