(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 109025 - TUBE ENDOTRACHEAL ORAL/NASAL UNCUFFED 2.5MM ID MAGILL SILICONE STAINLESS STEEL REINFORCED

Smiths Medical # 109025 - TUBE ENDOTRACHEAL ORAL/NASAL UNCUFFED 2.5MM ID MAGILL SILICONE STAINLESS STEEL REINFORCED
Part Number Smiths Medical 109025
SKU Number CIA1073262
Sell Unit EACH
Ships Within Special Order
List Price $73.97
Enter a valid quantity
Product Description

Smiths Medical 109025 - TUBE ENDOTRACHEAL ORAL/NASAL UNCUFFED 2.5MM ID MAGILL SILICONE STAINLESS STEEL REINFORCED

The Smiths Medical 109025 Endotracheal Tube is a high-quality, uncuffed airway management device designed for oral or nasal intubation in neonatal and pediatric patients. Featuring a 2.5mm internal diameter, this tube is engineered with a Magill curve for precise anatomical alignment and ease of insertion. Constructed from soft, medical-grade silicone and reinforced with stainless steel, it provides exceptional flexibility while maintaining structural integrity, minimizing the risk of kinking during critical procedures.

This endotracheal tube is specifically developed for situations where delicate airway management is required, ensuring patient safety and clinician confidence in both routine and emergency settings.

Key Benefits

The silicone construction enhances patient comfort while reducing mucosal irritation during insertion and prolonged use. The stainless steel reinforcement ensures consistent lumen patency, even under bending or positioning stress. Its Magill curve supports smoother navigation through the airway, improving placement accuracy and reducing procedure time. The uncuffed design is ideal for neonatal and pediatric use, minimizing pressure on sensitive tracheal tissues. Additionally, the tube offers excellent visibility and handling for clinicians during intubation.

Compatibility and Applications

This endotracheal tube is compatible with standard ventilation systems, anesthesia machines, and resuscitation equipment. It is widely used in neonatal intensive care units, pediatric operating rooms, emergency departments, and transport settings. Suitable for both oral and nasal intubation, it is ideal for airway management during surgical procedures, respiratory support, and critical care interventions in small patients.

Usage Guidelines

Prior to use, clinicians should verify the correct size and ensure the tube is free from defects. Lubrication may be applied to facilitate smooth insertion. The tube should be inserted following standard intubation protocols, with placement confirmed through appropriate clinical methods such as capnography or auscultation. Continuous monitoring is recommended to ensure proper positioning and airway patency throughout use.

Certifications and Safety Standards

The Smiths Medical 109025 Endotracheal Tube is manufactured in compliance with stringent medical device quality standards. It adheres to recognized international safety and performance requirements, ensuring reliability in critical care environments. The materials used are biocompatible and suitable for sensitive patient populations, including neonates and infants.

Comparison with Competitors

Compared to standard PVC endotracheal tubes, this silicone-based design offers superior flexibility and reduced risk of airway trauma. The stainless steel reinforcement provides a distinct advantage in maintaining lumen integrity under challenging conditions, outperforming non-reinforced alternatives. Its Magill curve design enhances ease of insertion, making it a preferred choice among clinicians seeking precision and consistency in airway management.

Typical User Profile and Application Scenarios

This product is commonly used by anesthesiologists, respiratory therapists, emergency physicians, and critical care specialists. It is particularly valuable in neonatal and pediatric settings where airway structures are delicate and require precise handling. Typical scenarios include surgical anesthesia, neonatal resuscitation, intensive care ventilation, and emergency airway stabilization.

Best Practices for Use and Maintenance

Single-use application is recommended to maintain sterility and prevent cross-contamination. The tube should be stored in a clean, dry environment and handled using aseptic techniques. After use, it should be disposed of in accordance with medical waste regulations. Clinicians should avoid excessive force during insertion to prevent damage to both the device and patient tissues.

Regulatory and Safety Information

This device is intended for use by trained healthcare professionals only. Proper training in airway management is essential to ensure safe and effective use. The product should be used in accordance with established clinical guidelines and institutional protocols. Any signs of damage or compromise should result in immediate disposal of the device.

How to Order

Select the Smiths Medical 109025 TUBE ENDOTRACHEAL ORAL/NASAL UNCUFFED 2.5MM ID MAGILL SILICONE STAINLESS STEEL REINFORCED. and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products