(312) 275-5850 9-5pm CST
0 CART $0.00
Your shopping cart is empty.
CIA Medical Google Customer Reviews – Central Infusion Alliance
CIA Medical BBB Accredited A+ Business – Central Infusion Alliance
CIA Medical Digicert EV Secure – Central Infusion Alliance
Menu

Smiths Medical 21-2946-24 - Gripper Needle, 20G x 5/8", with Y Site, 12/bx

Gripper Needle, 20G x 5/8
Part Number Smiths Medical 21-2946-24
SKU Number CIA8065737
Sell Unit BOX
Ships Within Special Order
List Price $132.77
Enter a valid quantity
Product Description

Smiths Medical 21-2946-24 - Gripper Needle, 20G x 5/8", with Y Site, 12/bx

The Smiths Medical 21-2946-24 Gripper Needle is a precision-engineered safety infusion needle designed for reliable access to implanted ports. Featuring a 20-gauge needle with a 5/8-inch length and an integrated Y site, this device supports efficient medication administration and fluid delivery in clinical settings. Built with clinician usability and patient comfort in mind, the Gripper Needle ensures stable placement, reduced needlestick risk, and consistent performance across a wide range of infusion therapies. Each box contains 12 individually packaged sterile units, making it a dependable choice for hospitals, oncology centers, and outpatient facilities.

Key Benefits

The ergonomic design allows for secure handling and controlled insertion, improving clinician confidence during procedures. The integrated Y site provides convenient secondary access for simultaneous administration of compatible fluids or medications without additional punctures. Its safety-oriented construction helps reduce the risk of accidental needlestick injuries, supporting a safer working environment. The 20G size ensures optimal flow rates while maintaining patient comfort, and the 5/8-inch length is ideal for accessing most implanted ports. Sterile, single-use packaging enhances infection control and ensures readiness for immediate use.

Compatibility and Applications

This Gripper Needle is compatible with standard implanted port systems commonly used in oncology, hematology, and long-term infusion therapies. It is suitable for chemotherapy delivery, antibiotic infusions, parenteral nutrition, hydration therapy, and blood sampling where appropriate. The Y site enables connection with IV tubing, syringes, and infusion pumps, allowing seamless integration into existing clinical workflows. Its design supports both inpatient and outpatient applications, including infusion clinics and home healthcare under professional supervision.

Usage Guidelines

Before use, ensure that the packaging is intact and the device remains sterile. Clean the access site thoroughly according to institutional protocols. Insert the needle into the port septum at a 90-degree angle, applying steady and controlled pressure. Once properly seated, secure the needle using appropriate stabilization methods. Connect primary and secondary lines as needed through the Y site. Monitor the infusion closely for flow consistency and patient response. After use, follow proper disposal procedures in compliance with sharps safety regulations.

Certifications and Safety Standards

The Smiths Medical Gripper Needle is manufactured in compliance with recognized healthcare quality standards. It meets stringent requirements for sterility, biocompatibility, and performance. Each unit undergoes rigorous quality control to ensure reliability and consistency. The product aligns with safety guidelines for single-use medical devices and supports infection prevention protocols in clinical environments.

Comparison with Competitors

Compared to other port access needles, the Smiths Medical Gripper Needle stands out for its balance of safety, usability, and efficiency. The integrated Y site reduces the need for additional connectors, streamlining the infusion process. Its ergonomic grip and stable design offer improved handling over more basic needle models. While some alternatives may focus solely on cost, this product delivers long-term value through consistent performance, reduced complications, and enhanced clinician confidence.

Typical User Profile and Application Scenarios

This product is widely used by oncology nurses, infusion therapists, and healthcare professionals responsible for administering long-term intravenous therapies. It is particularly beneficial in cancer treatment centers, outpatient infusion clinics, and hospitals where reliable port access is critical. Home healthcare providers may also utilize this needle under proper supervision for patients requiring ongoing infusion therapy.

Best Practices for Use and Maintenance

Always adhere to aseptic techniques during preparation and insertion. Use appropriate personal protective equipment to maintain safety and hygiene. Ensure secure placement to prevent dislodgement during infusion. Regularly inspect connections and tubing for leaks or blockages. Dispose of the needle immediately after use in an approved sharps container. Do not attempt to reuse or resterilize the device, as it is intended for single-use only.

Regulatory and Safety Information

This device is intended for use by trained healthcare professionals. It should be used in accordance with institutional guidelines and applicable medical regulations. Proper handling and disposal are essential to prevent injury and contamination. Users must follow all recommended safety protocols, including sharps handling procedures and infection control measures. Any adverse events or product concerns should be reported according to regulatory requirements.

How to Order

To place an order for the Smiths Medical 21-2946-24 Gripper Needle 20G x 5/8" with Y Site, 12 per box, please contact CIA Medical at (312) 275-5850. Our team is available to assist with product inquiries, bulk pricing, and fast shipping options to meet your facilitys needs.

Related Products