Smiths Medical 21-4187-24 - TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 2.8MM OD PLASTIC PORT 8.4FR 76CM SILICONE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE VESSEL DILATOR 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER UNASSEMBLED

TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 2.8MM OD PLASTIC PORT 8.4FR 76CM SILICONE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE VESSEL DILATOR 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER UNASSEMBLED
Part Number Smiths Medical 21-4187-24
SKU Number CIA1074213
Sell Unit EACH
Ships Within Special Order
List Price $402.54
Enter a valid quantity
Product Description

Smiths Medical 21-4187-24 - TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 2.8MM OD PLASTIC PORT 8.4FR 76CM SILICONE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE VESSEL DILATOR 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER UNASSEMBLED

The Smiths Medical 21-4187-24 Port-a-Cath Single Lumen Low Profile Plastic Port Tray is a comprehensive implantable vascular access tray designed for clinicians who require a reliable, low profile port system for long-term venous access procedures. This tray includes a single lumen low profile plastic port with a 1mm inner diameter and 2.8mm outer diameter, paired with an 8.4FR, 76cm silicone catheter for controlled vascular access in appropriate clinical settings.

Supplied as an unassembled tray, this Port-a-Cath system gives trained healthcare professionals the flexibility to prepare and position the components according to procedural requirements and institutional protocol. The tray configuration includes key access and placement components such as a straight/blunt needle, vein pick, 18GA introducer needle, J guidewire, vessel dilator, 90 degree needle, gripper needle, two syringes, and tunneler.

Key Benefits

The low profile plastic port design helps reduce external prominence after implantation while supporting patient comfort during long-term therapy. The single lumen configuration provides a straightforward access pathway for therapies that require dependable venous access without the complexity of multiple lumen systems.

The 8.4FR silicone catheter is designed for flexibility and biocompatibility in vascular access applications. The 76cm catheter length supports procedural adaptability, while the included placement accessories help streamline preparation by providing essential components in one tray.

The unassembled format allows clinicians to manage component preparation based on the selected technique, patient anatomy, and facility standards. This can be especially useful in procedural environments where controlled setup and clinician preference are important.

Compatibility and Applications

The Smiths Medical 21-4187-24 Port-a-Cath tray is intended for use in clinical environments where implantable venous access ports are required. Typical applications may include long-term medication delivery, infusion therapy, blood sampling where clinically appropriate, and other vascular access needs determined by a licensed healthcare provider.

The tray is suitable for use by trained physicians and clinical teams experienced in implantable port placement. It is commonly applicable in hospitals, interventional radiology suites, oncology departments, surgical centers, and other controlled healthcare settings that perform vascular access procedures.

Compatibility should always be confirmed with the facilitys vascular access protocols, infusion requirements, catheter care procedures, and any applicable manufacturer guidance before use.

Usage Guidelines

This product should be used only by qualified healthcare professionals trained in implantable port placement and vascular access management. Before use, inspect the packaging and tray contents to confirm sterility, product integrity, and correct sizing for the intended procedure.

Clinicians should follow aseptic technique throughout preparation, placement, and post-placement care. The port and catheter should be prepared according to the manufacturers instructions for use and the facilitys clinical policies. Proper imaging, placement confirmation, securement, and flushing protocols should be followed as applicable.

After placement, ongoing care should include routine access site monitoring, catheter patency checks, flushing according to institutional policy, and patient education on signs of possible complications such as infection, swelling, pain, leakage, or difficulty with access.

Certifications and Safety Standards

The Smiths Medical 21-4187-24 Port-a-Cath tray is manufactured for professional healthcare use and should be handled in accordance with applicable medical device regulations, facility infection control standards, and vascular access safety protocols.

Users should refer to the product labeling and instructions for use for complete information on sterility, storage, contraindications, warnings, precautions, and recommended handling. Facility staff should verify that the product meets purchasing, clinical, and regulatory requirements before use in patient care.

Comparison with Competitors

Compared with general vascular access components purchased separately, this Port-a-Cath tray offers a more procedure-ready configuration by combining the port, silicone catheter, introducer needle, guidewire, dilator, tunneler, syringes, and access needles in a single organized tray. This can reduce the need to source multiple individual items and may help improve procedural efficiency.

The low profile single lumen design is well suited for cases where a compact implantable port is preferred. While some competing systems may offer different materials, lumen options, or preassembled configurations, the Smiths Medical 21-4187-24 tray provides a balanced option for clinicians who need a low profile plastic port with an 8.4FR silicone catheter and flexible unassembled setup.

Typical User Profile and Application Scenarios

This product is typically used by vascular access specialists, interventional radiologists, surgeons, oncology care teams, and trained procedural clinicians. It is appropriate for healthcare facilities that manage patients requiring reliable long-term venous access under professional supervision.

Common application scenarios include planned port placement for ongoing infusion therapy, treatment courses requiring repeated venous access, and clinical cases where a low profile implantable access device is preferred. Patient suitability should always be assessed by the treating clinician based on therapy type, vascular anatomy, medical history, and procedural risk factors.

Best Practices for Use and Maintenance

Store the tray in a clean, dry environment according to the manufacturers recommended storage conditions. Do not use the product if packaging is damaged, opened, expired, or compromised in any way.

Before the procedure, confirm that all required components are present and appropriate for the planned placement. During use, maintain strict sterile technique and follow all facility requirements for vascular access placement, sharps handling, catheter trimming if applicable, flushing, and documentation.

For ongoing maintenance, use only approved access needles and follow facility protocols for flushing, locking solution, dressing changes, and site assessment. Educate patients on proper care expectations and when to report symptoms that may indicate infection, occlusion, displacement, or other complications.

Regulatory and Safety Information

The Smiths Medical 21-4187-24 Port-a-Cath Single Lumen Low Profile Plastic Port Tray is intended for professional medical use only. It should not be used by untrained individuals or outside appropriate clinical settings.

Healthcare providers should review the complete manufacturer instructions, warnings, precautions, contraindications, and device-specific labeling before use. Proper patient selection, sterile handling, placement verification, and post-procedure monitoring are essential to safe and effective use.

All used needles, sharps, and disposable components should be discarded according to facility policy and applicable medical waste regulations. Any adverse events or suspected product issues should be reported through the appropriate clinical and regulatory channels.

How to Order

Select the Smiths Medical 21-4187-24 TRAY PORT-A-CATH SINGLE LUMEN LOW PROFILE 1MM ID 2.8MM OD PLASTIC PORT 8.4FR 76CM SILICONE CATHETER STRAIGHT/BLUNT NEEDLE VEIN PICK 18GA INTRODUCER NEEDLE J GUIDEWIRE VESSEL DILATOR 90 DEG NEEDLE GRIPPER NEEDLE SYRINGEX2 TUNNELER UNASSEMBLED and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.

Related Products