-
Catheters (6,800+)
- Angiocatheters (50+)
- Closed System Catheters (300+)
- External Catheters (620+)
- Hydrophilic Catheters (140+)
- IV Catheters (1,200+)
- Non-Hydrophilic (20+)
- Plastic Catheters (200+)
- Rubber Catheters (700+)
- Silicone Catheters (770+)
- Ureteral Catheters (100+)
- Urethral Catheters (450+)
- Venous Catheters (240+)
-
Coronavirus (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (20,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Custom Kits
- Dental (14,000+)
- Gloves (8,000+)
-
Gynecology & Urology (1,000+)
- Bed Side Drainage Bags (350+)
- Circumcision (150+)
- Cord Clamps and Clippers (60+)
- Disposable Vaginal Specula (60+)
- Enema Bags (30+)
- External Catheters (620+)
- Foley Catheters and Trays (1,200+)
- Identification (1100+)
- Leg Bag Accessories (10+)
- Leg Bags (280+)
- Reusable Vaginal Specula (900+)
- Specimen Collection (200+)
- Tubing & Connectors (17,000+)
- Urinals / Bed Pans (1,300+)
- Urine Collectors (60+)
- Urological Irrigation Products (10+)
- Vaginal Specula Illumination (2+)
- Systems (11,000+)
- Hygiene (1,000+)
- Incontinence (1,000+)
-
Infection Control (2,500+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Iodine (460+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Infusion All (2,000+)
- IV Bags - Empty (300+)
- IV Bags - Filled (100+)
- Masks (3,800+)
-
Medical Apparel (23,000+)
- Arm Sleeves (240+)
- Beard Covers (20+)
- Bouffant Caps (200+)
- Compression Socks (80+)
- Coveralls (500+)
- Disposables (100+)
- Isolation Gowns (360+)
- Lab Coats (2,200+)
- Lab Jackets (300+)
- Patient Gowns (300+)
- Procedural Gowns (230+)
- Scrubs (20,000+)
- Shoe Covers (270+)
- Surgeon Caps (40+)
- Surgical Gowns (70+)
- Surgical Hoods (20+)
- Surgical Masks (330+)
- Ostomy (400+)
-
PPE (20,000+)
- Bacterial Filters (170+)
- Bleach (360+)
- Coveralls (500+)
- Disinfectant Wipes (350+)
- Face Shields (200+)
- Gloves (8,000+)
- Gowns (2,300+)
- Isopropyl Alcohol (170+)
- IV Therapy (2,000+)
- Masks (3,700+)
- Pulse Oximeters (250+)
- Sanitizer (670+)
- Scrubs (23,000+)
- Soap (1,500+)
- Stethoscopes (700+)
- Thermometers (950+)
- Respiratory (500+)
- Sanitizer (600+)
- Surgical Supplies (14,000+)
- Sutures (7,500+)
- Syringes & Needles (14,000+)
-
Wound Care (5,000+)
- ABD Pads (100+)
- Adhesive Bandages (650+)
- Advanced Wound Care (400+)
- Applicators (6,700+)
- Burn care (240+)
- Dressings (7,500+)
- Elastic Bandages (1,600+)
- Gauze (3,300+)
- Ice / Heat Packs (280+)
- Medical Tape (820+)
- Non-Adhering Dressings (100+)
- Ointment & Solutions (450+)
- Self-Adherent Wraps (200+)
- Sponges (2,400+)
- Staple & Suture Removal (1,500+)
- Tegaderm (450+)
- Transparent Dressing (800+)
- Wound Care Prep (120+)
- Wound Cleansers (100+)
- Sales & Deals (100+)
- 3M (4,200+)
- Alaris Medical (600+)
- Amsino International (550+)
- Avanos Medical (40+)
- B Braun (1,500+)
- Baxter (750+)
- BD (2,800+)
- BSN Medical (2,000+)
- Cables & Sensors (3,200+)
- C.R. Bard (4,200+)
- Cardinal Health (6,800+)
- CareFusion (2,100+)
- ConMed (1,500+)
- Cook Medical (600+)
- Covidien (9,500+)
- DeRoyal (6,000+)
- Dukal (1,300+)
- Ethicon (4,100+)
- GE Healthcare (1,000+)
- Hartmann (600+)
- Hospira (530+)
- ICU Medical (1,700+)
- Masimo (170+)
- Medline (54,000+)
- Midmark (2,500+)
- Roche (300+)
- Smiths Medical (4,000+)
- Sunset Healthcare (450+)
- TrueCare Biomedix (20+)
- View All Brands (5,000+)
Smiths Medical 21-4436-24 - Port-A-Cath Kit, Includes: Single-Lumen Low Profile Portal, Titanium, 25x11.5x9.5mm, PolyFlow Polyurethane Catheter, 5.8FR, Straight Needle, Blunt Needle, Vein Pick, and Point-Lok Device
The Smiths Medical 21-4436-24 Port-A-Cath Kit is designed for long-term vascular access procedures where a compact, low profile implanted portal and reliable catheter performance are required. This kit includes a single-lumen low profile titanium portal measuring 25x11.5x9.5mm, a 5.8FR PolyFlow polyurethane catheter, straight needle, blunt needle, vein pick, and Point-Lok device.
Built for clinical efficiency and patient comfort, this Port-A-Cath kit supports dependable venous access for therapies that may require repeated infusion or aspiration. The low profile titanium portal helps reduce prominence under the skin, while the polyurethane catheter is intended to provide flexibility and durability during appropriate clinical use.
Key Benefits
- Single-lumen low profile portal supports streamlined vascular access for appropriate infusion therapy protocols.
- Titanium portal construction offers strength, durability, and biocompatible performance for implanted access applications.
- Compact 25x11.5x9.5mm portal design helps support patient comfort and reduced visibility after placement.
- 5.8FR PolyFlow polyurethane catheter provides flexibility for controlled catheter positioning and dependable fluid delivery.
- Included straight needle, blunt needle, vein pick, and Point-Lok device help support procedural readiness.
- Designed for use by trained healthcare professionals in sterile clinical environments.
Compatibility and Applications
The Smiths Medical 21-4436-24 Port-A-Cath Kit is intended for use in clinical settings where implanted venous access is required. It may be used as part of treatment plans involving repeated access for infusion therapy, blood sampling, hydration, medication administration, or other physician-directed vascular access needs.
The kit components are designed to work together as a procedural set, helping clinicians reduce the need to gather separate accessories. The low profile titanium portal and 5.8FR polyurethane catheter are suited for patients requiring a compact implanted access solution, subject to clinical assessment, facility protocol, and product instructions for use.
Usage Guidelines
This product should be used only by qualified healthcare professionals trained in implanted vascular access procedures. Before use, inspect the packaging and components to confirm that the sterile barrier is intact and that the product has not been damaged or expired.
Placement, catheter trimming, tunneling, access technique, flushing, and maintenance should be performed according to the manufacturers instructions for use, institutional policy, and applicable clinical guidelines. Proper aseptic technique must be maintained throughout preparation, implantation, access, and post-procedure care.
The portal should be accessed only with appropriate non-coring needles when clinically indicated. Follow established protocols for flushing, locking, dressing changes, site assessment, and monitoring for complications such as infection, occlusion, infiltration, thrombosis, or catheter-related issues.
Certifications and Safety Standards
The Smiths Medical 21-4436-24 Port-A-Cath Kit is manufactured for professional medical use and should be handled in accordance with applicable healthcare regulations, facility procedures, and manufacturer labeling. Users should verify current product documentation for sterilization method, indications, contraindications, warnings, and storage requirements.
As with all implantable vascular access devices, safety depends on proper patient selection, correct placement technique, sterile handling, routine maintenance, and ongoing clinical monitoring. The product should not be used if packaging is opened, damaged, or compromised.
Comparison with Competitors
Compared with standard implanted port options, the Smiths Medical 21-4436-24 Port-A-Cath Kit offers the advantage of a low profile titanium portal paired with a 5.8FR polyurethane catheter in a complete procedural configuration. Its compact portal size may be beneficial where reduced device prominence and patient comfort are important considerations.
Some competing port systems may require separate accessory selection or may feature larger portal dimensions depending on the configuration. This kit provides a focused single-lumen solution with essential procedural components included, helping support consistency, workflow efficiency, and clinical convenience.
Typical User Profile and Application Scenarios
This kit is commonly used by interventional radiologists, surgeons, oncology teams, vascular access specialists, and other trained clinicians responsible for long-term venous access management. It is suited for hospitals, outpatient surgical centers, infusion centers, oncology facilities, and specialized vascular access programs.
Typical application scenarios include patients who require repeated venous access over an extended period and may benefit from an implanted access device instead of frequent peripheral venipuncture. Final product selection should be based on patient anatomy, therapy type, expected duration of treatment, clinician preference, and institutional protocol.
Best Practices for Use and Maintenance
Use strict aseptic technique during implantation, access, dressing changes, and maintenance procedures. Confirm catheter position and portal function according to clinical protocol before use. Educate care teams on proper access technique, flushing intervals, and signs that require clinical evaluation.
Routine inspection of the access site is important to identify redness, swelling, tenderness, drainage, leakage, or other signs of possible complications. Maintain accurate documentation of implantation details, access events, flushes, medication administration, and any patient-reported symptoms.
Store the kit in a clean, dry environment and protect it from damage, excessive heat, moisture, and contamination. Do not resterilize or reuse components intended for single use. Dispose of needles, sharps, and used components according to facility policy and applicable medical waste regulations.
Regulatory and Safety Information
The Smiths Medical 21-4436-24 Port-A-Cath Kit is a professional medical device intended for use under the direction of licensed healthcare providers. Review the manufacturers instructions for use before handling, implanting, accessing, or maintaining the device.
Healthcare providers should follow all applicable federal, state, local, and facility requirements for implantable vascular access devices. Patient assessment, informed consent, sterile technique, correct placement, and ongoing monitoring are essential to safe and effective use. This content is for product information only and does not replace clinical judgment or manufacturer documentation.
How to Order
Select the Smiths Medical 21-4436-24 Port-A-Cath Kit, Includes: Single-Lumen Low Profile Portal, Titanium, 25x11.5x9.5mm, PolyFlow Polyurethane Catheter, 5.8FR, Straight Needle, Blunt Needle, Vein Pick, and Point-Lok Device and add it to your cart. Complete checkout with your preferred shipping and payment options. For bulk orders, quotes, or further assistance, contact CIA Medical customer service at (312)275-5850 or use the contact form on this page.
Smiths Medical #21-4482-24, Port-A-Cath Kit, Includes: Single-Lumen Low Profile Portal, Polysulfone/Titanium, 25x11.5x9.5mm, PolyFlow Polyurethane Catheter, 5.8FR, Straight Needle, Blunt Needle, Vein Pick, and Point-Lok Device
$1,052.17 EACH
Smiths Medical #21-4485-24, Port-A-Cath Kit, Includes: Single-Lumen Low Profile Portal, Polysulfone/Titanium, 25x11.5x9.5mm, PolyFlow Polyurethane Catheter, 5.8FR, Straight Needle, Vein Pick, and Point-Lok Device
$1,052.17 EACH
Smiths Medical #21-4470-24, Port-A-Cath Kit, Includes: Single-Lumen Low Profile Portal, Polysulfone/Titanium, 25x11.5x9.5mm, PolyFlow Polyurethane Catheter, 7.8FR, Straight Needle, Blunt Needle, Vein Pick, and Point-Lok Device
$1,052.17 EACH
Smiths Medical #21-4424-24, Port-A-Cath Kit, Includes: Single-Lumen Standard Portal, Titanium, 30.5x14.7x11.4mm, PolyFlow Polyurethane Catheter, 5.8FR, Straight Needle, Blunt Needle, Vein Pick, and Point-Lok Device
$1,052.19 EACH